《ASTM C1494-2001(2007) Standard Test Methods for Determination of Mass Fraction of Carbon Nitrogen and Oxygen in Silicon Nitride Powder《氨化硅粉末中碳、氮和氧的质量分数测定的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1494-2001(2007) Standard Test Methods for Determination of Mass Fraction of Carbon Nitrogen and Oxygen in Silicon Nitride Powder《氨化硅粉末中碳、氮和氧的质量分数测定的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1494 01 (Reapproved 2007)Standard Test Methods forDetermination of Mass Fraction of Carbon, Nitrogen, andOxygen in Silicon Nitride Powder1This standard is issued under the fixed designation C 1494; the number immediately following the designation indicates the year oforiginal adoption
2、 or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover the determination of massfraction % of carbon, nit
3、rogen and oxygen in silicon nitridepowder having chemical compositions within the followinglimits:Element Mass Fraction % RangeCarbon 0.05 to 5.0Nitrogen 30 to 45Oxygen 0.1 to 1.51.2 Two test methods appear in this standard.1.2.1 Total Carbon by the Direct Combustion-Infrared Mea-surement Method.1.2
4、.2 Nitrogen and oxygen by the Inert Gas Fusion-ThermalConductivity Measurement Method.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices a
5、nd determine the applica-bility of regulatory limitations prior to use. Specific hazardstatements are given in Section 6.2. Referenced Documents2.1 ASTM Standards:2E29 Practice for Using Significant Digits in Test Data toDetermine Conformance with SpecificationsE50 Practices for Apparatus, Reagents,
6、 and Safety Consid-erations for Chemical Analysis of Metals, Ores, andRelated MaterialsE 1019 Test Methods for Determination of Carbon, Sulfur,Nitrogen, and Oxygen in Steel and in Iron, Nickel, andCobalt AlloysE 1409 Test Method for Determination of Oxygen andNitrogen in Titanium and Titanium Alloys
7、 by the Inert GasFusion TechniqueE 1569 Test Method for Determination of Oxygen in Tan-talum PowderE 1806 Practice for Sampling Steel and Iron for Determi-nation of Chemical CompositionE 1941 Test Method for Determination of Carbon in Refrac-tory and Reactive Metals and Their Alloys3. Significance a
8、nd Use3.1 These test methods are for the chemical analysis of massfraction of carbon, nitrogen and oxygen in silicon nitridepowder. It is assumed that all who use these test methods willbe trained analysts, capable of performing common laboratoryprocedures skillfully and safely. It is expected that
9、work will beperformed in a properly equipped laboratory.4. Apparatus and Reagents4.1 The procedure was written with commercial carbon andnitrogen/oxygen analyzers in mind. For any other analyzer, theinstrument manual specific to that analyzer shall be consultedfor instrument set-up.4.2 Specific appa
10、ratus and reagents required for each deter-mination are listed in separate sections preceding the procedure.5. Sampling5.1 Procedures for sampling the materials refer to thoseparts of Practice E 1806 pertaining to solid form samples of thetype used for instrumental analysis.6. Hazards6.1 For hazards
11、 to be observed in the use of certain reagentsin this test method, refer to Practice E50.1These test methods are under the jurisdiction of ASTM Committee C28 onAdvanced Ceramics and are the direct responsibility of Subcommittee C28.03 onPhysical Properties and Performance.Current edition approved No
12、v. 1, 2007. Published December 2007. Originallyapproved in 2001. Last previous edition approved in 2001 as C 1494 01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to
13、 the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.2 Use care when handling hot crucibles and operatingfurnaces to avoid personal injury by either burn or electricalshock.7. Tota
14、l Carbon in Silicon Nitride Powder by DirectCombustionInfrared Detection Method7.1 ScopeThis test method covers the determination ofcarbon in concentrations from 0.05 to 5.0 % mass fraction.7.2 Summary of Test Method3The carbon is converted tocarbon dioxide by combustion in a stream of oxygen. Theam
15、ount of carbon dioxide is measured by infrared (IR)absorption.7.3 ApparatusThis test method is written for use withcommercial carbon analyzers, equipped to carry out the analy-ses operations automatically and calibrated using steel stan-dards with known concentrations of carbon. The operatingprincip
16、les, specifications and descriptions of commercial car-bon analyzers are given in the Practice of E 1019.7.4 Reagents and Materials:7.4.1 CruciblesExpendable ceramic (alumina) or similarrefractory crucibles as specified by commercial carbon analyz-ers manufacturers. Both the crucible and cover, if u
17、sed, mustbe prebaked for a sufficient time to produce constant blankvalues. Use the prebake schedule recommended by the instru-ment manufacturer.7.4.2 Crucible TongsCapable of handling recommendedcrucibles with respect to their sizes, shape and temperature.7.4.3 AcceleratorsCarbon free (or containin
18、g a knownamount of carbon) granular tungsten/tin and iron chip accel-erators shall be used.7.4.4 Carbon Standard MaterialNIST SRM 8j(0.081 %C), SRM 1 lh (0.2 %C), SRM 12h (0.407 %C), andNIST RM 8983 (0.107 %C).7.4.5 OxygenUltra High Purity (99.95 % minimum pu-rity) or Regular grade (99.5 %) purified
19、 by passing over heatedCuO and through CO2/H20 absorbents. (When the instrumenthas a built in purifier, regular grade oxygen can be used.)7.5 Preparation of ApparatusFollow the operating in-structions for the specific equipment used. After having prop-erly set the operating controls of the instrumen
20、t system,condition the apparatus by combustion of several blanksprepared with sample crucible and accelerator in the amountsto be used with the test specimen analyses. Successive blanksshould achieve a steady state value.7.6 Blank Determination:7.6.1 Prebake ceramic crucibles in a muffle or tube fur
21、naceat 1350 C for not less than 15 min or at 1000 C for not lessthan 40 minutes. The crucibles shall be removed from thefurnace, allowed to cool for 1-2 min and placed in a desiccatorfor storage. If the crucibles are not used within four hours, theymust be prebaked again. This prebaking procedure is
22、 to burnoff any organic contaminates.7.6.2 Prepare instrument as outlined in the operators in-struction manual.7.6.3 Determine the instrument blank.(a) Enter 1.000 g weight into weight stack.(b) Add 1.000 g (6 0.005 g) of tungsten/tin accelerator and1.000 g (6 0.005 g) of iron chip accelerator.(c) P
23、lace crucible on furnace pedestal and analyze.(d) Repeat steps 7.6.3a through 7.6.3c a minimum of threetimes.(e) Enter blank value following routine outlined in opera-tors instruction manual.7.7 Instrument Calibration Procedure:7.7.1 This procedure was written specially for a carbonanalyzer. The typ
24、e and amounts of accelerator to be added shallbe adjusted according to the manufacturers recommendationsfor the other instrumentation.7.7.2 Weigh 0.1 to 0.5 g of calibration standard to thenearest mg into a prebaked ceramic or similar refractorycrucible and enter appropriate weight into weight stack
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC149420012007STANDARDTESTMETHODSFORDETERMINATIONOFMASSFRACTIONOFCARBONNITROGENANDOXYGENINSILICONNITRIDEPOWDER

链接地址:http://www.mydoc123.com/p-464858.html