ASTM C1491-2013 Standard Specification for Concrete Roof Pavers《混凝土屋面摊铺机的标准规格》.pdf
《ASTM C1491-2013 Standard Specification for Concrete Roof Pavers《混凝土屋面摊铺机的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1491-2013 Standard Specification for Concrete Roof Pavers《混凝土屋面摊铺机的标准规格》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1491 11C1491 13Standard Specification forConcrete Roof Pavers1This standard is issued under the fixed designation C1491; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parenthes
2、es indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers concrete roof pavers that are machine-made from hydraulic cement, water, and suitable mineralaggregates with or without the inc
3、lusion of other materials, for use as roof ballast and protection of roof membranes.NOTE 1The design of roof ballast systems for resisting wind uplift is beyond the scope of this specification. Building codes and other standards shouldbe consulted in designing for wind uplift resistance.1.2 The text
4、 of this standard references notes and footnotes that provide explanatory material. These notes and footnotes(excluding those in tables and figures) shall not be considered as requirements of the standard.1.3 The values stated in inch-pound units are to be regarded as standard. The values given in p
5、arentheses are mathematicalconversions to SI units that are provided for information only and are not considered standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appro
6、priate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C33 Specification for Concrete AggregatesC140 Test Methods for Sampling and Testing Concrete Masonry Units and Related UnitsC150 Specification for Portl
7、and CementC331 Specification for Lightweight Aggregates for Concrete Masonry UnitsC595 Specification for Blended Hydraulic CementsC618 Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in ConcreteC989 Specification for Slag Cement for Use in Concrete and MortarsC1157 Perfor
8、mance Specification for Hydraulic CementC1209 Terminology of Concrete Masonry Units and Related Units (Withdrawn 2009)3C1232 Terminology of MasonryC1262 Test Method for Evaluating the Freeze-Thaw Durability of Dry-Cast Segmental Retaining Wall Units and RelatedConcrete Units3. Terminology3.1 Termino
9、logy defined in Terminology C1209 and Terminology C1232 shall apply to this specification.4. Material4.1 Cementitious MaterialsMaterials shall conform to the following applicable specifications:4.1.1 Portland CementSpecification C150.4.1.2 Modified Portland CementPortland cement conforming to Specif
10、ication C150, modified as follows:1 This specification is under the jurisdiction of ASTM Committee C15 on Manufactured Masonry Units and is the direct responsibility of Subcommittee C15.03 onConcrete Masonry Units and Related Units.Current edition approved Dec. 1, 2011Dec. 1, 2013. Published Decembe
11、r 2011December 2013. Originally approved in 2001. Last previous edition approved in 20092011as C1491 03C1491 11. (2009). DOI: 10.1520/C1491-11.10.1520/C1491-13.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of
12、ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 The last approved version of this historical standard is referenced on www.astm.org.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of
13、 what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered
14、 the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.1.2.1 LimestoneLimestone, with a minimum 85 % calcium carbonate (CaCO3) content, shall be permit
15、ted to be added to thecement, provided the requirements of Specification C150 are modified as follows:(1) Limitation on Insoluble Residue1.5 %.(2) Limitation on Air Content of MortarVolume percent, 22 % max.(3) Limitation on Loss on Ignition7 %.4.1.3 Blended CementsCement conforming to either Specif
16、ication C595 or Specification C1157.4.1.4 PozzolansSpecification C618.4.1.5 Blast Furnace SlagSpecification C989.4.2 AggregatesAggregates shall conform to the following specifications, except that grading requirements shall notnecessarily apply:4.2.1 Normal Weight AggregatesSpecification C33.4.2.2 L
17、ightweight AggregatesSpecification C331.4.3 Other ConstituentsAir-entraining agents, coloring pigments, integral water repellents, finely ground silica, and otherconstituents shall be previously established as suitable for use in concrete roof pavers and shall conform to applicable ASTMstandards or
18、shall be shown by test or experience satisfactory to the purchaser to be not detrimental to the durability of the unitsor any material customarily used in concrete roof pavers.5. Physical Requirements5.1 At the time of delivery to the work site, the units shall conform to the physical requirements o
19、f Table 1 when tested inaccordance with 8.2.5.2 Resistance to Flexural LoadThe average resistance to flexural load for three paver units shall exceed 350 lb (1557 N) andresistance to flexural load of each individual unit shall exceed 280 lb (1246 N) when tested in accordance with 8.2.5.3 Ballast Wei
20、ghtRequirements for ballast weight per unit area shall be specified separately.5.4 Freeze-Thaw DurabilityIn areas where repeated freezing and thawing under saturated conditions occur, freeze-thawdurability shall be demonstrated by test or by proven field performance that the concrete roof paver unit
21、s have adequate durabilityfor the intended use. When testing is required by the specifier to demonstrate freeze-thaw durability, the units shall be tested inaccordance with 8.3.5.4.1 Specimens shall comply with either of the following: (1) the weight loss of each of five test specimens at the conclu
22、sionof 100 cycles shall not exceed 1 % of its initial weight; or (2) the weight loss of each of four or five test specimens at the conclusionof 150 cycles shall not exceed 1.5 % of its initial weight.NOTE 2This specification does not include criteria for hail stone impact. Where required, these crit
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC14912013STANDARDSPECIFICATIONFORCONCRETEROOFPAVERS 混凝土 屋面 摊铺机 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-464851.html