ASTM C1478M-2008a(2013) Standard Specification for Storm Drain Resilient Connectors Between Reinforced Concrete Storm Sewer Structures Pipes and Laterals (Metric)《加筋混凝土排暴雨污水结构、管道和横.pdf
《ASTM C1478M-2008a(2013) Standard Specification for Storm Drain Resilient Connectors Between Reinforced Concrete Storm Sewer Structures Pipes and Laterals (Metric)《加筋混凝土排暴雨污水结构、管道和横.pdf》由会员分享,可在线阅读,更多相关《ASTM C1478M-2008a(2013) Standard Specification for Storm Drain Resilient Connectors Between Reinforced Concrete Storm Sewer Structures Pipes and Laterals (Metric)《加筋混凝土排暴雨污水结构、管道和横.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1478M 08a (Reapproved 2013)Standard Specification forStorm Drain Resilient Connectors Between ReinforcedConcrete Storm Sewer Structures, Pipes, and Laterals(Metric)1This standard is issued under the fixed designation C1478M; the number immediately following the designation indicates th
2、e year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers the minimum performance
3、andmaterial requirements for resilient connectors used for connec-tions between precast reinforced concrete storm sewer struc-tures conforming to Specification C478 and pipes, and betweenprecast reinforced concrete pipe and laterals for storm drainagesystems.1.1.1 These connectors are designed to pr
4、event soil migra-tion between the pipe and storm sewer structure, and betweenthe pipe and lateral.1.2 This specification is the SI companion to C1478.NOTE 1This specification covers the design, material, and perfor-mance of the resilient connection only. Connections covered by thisspecification are
5、adequate for hydrostatic pressures up to 41 kPa (4.3 m)without leakage when tested in accordance with Section 7. Infiltrationquantities for an installed system are dependent upon many factors otherthan the connections between storm sewer structures and pipe, andallowable quantities must be covered b
6、y other specifications and suitabletesting of the installed pipeline and system.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and det
7、ermine the applica-bility of regulatory requirements prior to use. For a specificwarning statement, see 7.2.4.2. Referenced Documents2.1 ASTM Standards:2A493 Specification for Stainless Steel Wire and Wire Rodsfor Cold Heading and Cold ForgingA666 Specification for Annealed or Cold-Worked Austenitic
8、Stainless Steel Sheet, Strip, Plate, and Flat BarC478 Specification for Precast Reinforced Concrete Man-hole SectionsC822 Terminology Relating to Concrete Pipe and RelatedProductsC913 Specification for Precast Concrete Water and Waste-water StructuresD395 Test Methods for Rubber PropertyCompression
9、SetD412 Test Methods for Vulcanized Rubber and Thermoplas-tic ElastomersTensionD471 Test Method for Rubber PropertyEffect of LiquidsD543 Practices for Evaluating the Resistance of Plastics toChemical ReagentsD573 Test Method for RubberDeterioration in an AirOvenF624 Guide for Evaluation of Thermopla
10、stic PolyurethaneSolids and Solutions for Biomedical ApplicationsD883 Terminology Relating to PlasticsD1149 Test Methods for Rubber DeteriorationCracking inan Ozone Controlled EnvironmentD1566 Terminology Relating to RubberD2137 Test Methods for Rubber PropertyBrittleness Pointof Flexible Polymers a
11、nd Coated FabricsD2240 Test Method for Rubber PropertyDurometer Hard-nessNOTE 2For more information about wastewater structures, see Speci-fication C913.3. Terminology3.1 Definitions:3.1.1 Terms relating to plastics and rubber shall be asdefined in Terminologies D883 and D1566, respectively.3.1.2 Te
12、rms relating to precast concrete pipe, manholes, andrelated products shall be as defined in Terminology C822.3.2 Definitions of Terms Specific to This Standard:3.2.1 connectorthe entire assembly, including resilientseals and metallic or nonmetallic mechanical devices, if any,used therein.3.2.2 later
13、althe small diameter pipe connected to themain line pipe.1This specification is under the jurisdiction of ASTM Committee C13 onConcrete Pipe and is the direct responsibility of Subcommittee C13.06 on Manholesand Specials.Current edition approved July 1, 2013. Published July 2013. Originally approved
14、in 2003. Last previous edition approved in 2008 as C1478M 08a. DOI: 10.1520/C1478M-08AR13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Sum
15、mary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.2.3 pipethe inlet or outlet pipe connected to the man-hole.3.2.4 pipe stuba short section of pipe installed in thestructure as an inlet or outlet pipe, for
16、 future connection.4. Materials and Manufacture4.1 All materials shall conform to the following require-ments:4.1.1 Resilient materials for connectors and filler rings shallbe manufactured from natural or synthetic rubber and shallconform to the requirements prescribed in Table 1. If a spliceis used
17、 in the manufacture of the seal, its strength shall be suchthat the seal shall withstand a 180 bend with no visibleseparation.4.2 Mechanical DevicesExpansion rings, tension bands,and take-up devices used for mechanically compressing theresilient portion of the connector against the pipe or stormsewe
18、r structure shall be made from a material or materials incombination that will ensure durability, strength, resistance tocorrosion, and have properties that will ensure continuedresistance to leakage. All metallic mechanical devices, includ-ing castings and bolt assemblies used to mechanically defor
19、mresilient materials, shall be constructed of corrosion resistantmaterials meeting the physical properties and chemical com-position requirements of Specifications A493 and A666, Type302 through Type 316.NOTE 3Experience has shown that successful performance of thisproduct depends on the type of bed
20、ding and backfill and the care in thefield installation of the manhole storm sewer structure and connectingpipes. The owner is cautioned to require inspection at the construction site.5. Principles of Design5.1 The design of the connector shall be such that positiveseal is accomplished at two locati
21、ons: (1) between the connec-tor and the storm sewer structure wall and (2) between theconnector and the pipe. The seal between the connector and thestorm sewer structure wall shall be made by either mechanicalmeans, compression of the resilient material between theoutside surface of the pipe and the
22、 pipe opening in the stormsewer structure wall, or by casting the connector integrallywith the storm sewer structure wall. The seal between theconnector and the pipe shall be made by mechanical means orby compression of the resilient material against the outside ofthe pipe. Resilient filler rings ar
23、e not prohibited from beingused between the pipe and the connector to provide a seal.Whichever design is used, it shall be capable of maintaining aresilient, hydrostatic seal under the performance conditions inaccordance with Section 7. Devices used to effect mechanicalseals shall conform to the req
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1478M2008A2013STANDARDSPECIFICATIONFORSTORMDRAINRESILIENTCONNECTORSBETWEENREINFORCEDCONCRETESTORMSEWERSTRUCTURESPIPESANDLATERALSMETRIC

链接地址:http://www.mydoc123.com/p-464793.html