《ASTM C1478M-2008 Standard Specification for Storm Drain Resilient Connectors Between Reinforced Concrete Storm Sewer Structures Pipes and Laterals (Metric).pdf》由会员分享,可在线阅读,更多相关《ASTM C1478M-2008 Standard Specification for Storm Drain Resilient Connectors Between Reinforced Concrete Storm Sewer Structures Pipes and Laterals (Metric).pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1478M 08METRICStandard Specification forStorm Drain Resilient Connectors Between ReinforcedConcrete Storm Sewer Structures, Pipes, and LateralsMetric1This standard is issued under the fixed designation C 1478M; the number immediately following the designation indicates the year oforig
2、inal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers the minimum performance andmaterial
3、requirements for resilient connectors used for connec-tions between precast reinforced concrete storm sewer struc-tures conforming to Specification C 478 and pipes, and be-tween precast reinforced concrete pipe and laterals for stormdrainage systems.1.1.1 These connectors are designed to prevent soi
4、l migra-tion between the pipe and storm sewer structure, and betweenthe pipe and lateral.1.2 The values stated in SI units are to be regarded asstandard. The values given in parentheses are for informationonly. This specification is the Metric counterpart of Specifica-tion C 1478.NOTE 1This specific
5、ation covers the design, material, and perfor-mance of the resilient connection only. Connections covered by thisspecification are adequate for hydrostatic pressures up to 41 kPa (4.3 m)without leakage when tested in accordance with Section 7. Infiltrationquantities for an installed system are depen
6、dent upon many factors otherthan the connections between storm sewer structures and pipe, andallowable quantities must be covered by other specifications and suitabletesting of the installed pipeline and system.1.3 This standard does not purport to address all of thesafety concerns, if any, associat
7、ed with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory requirements prior to use. For a specificwarning statement, see 7.2.4.2. Referenced Documents2.1 ASTM Standards:2A 493 Specificat
8、ion for Stainless Steel Wire and Wire Rodsfor Cold Heading and Cold ForgingA 666 Specification for Annealed or Cold-Worked Austen-itic Stainless Steel Sheet, Strip, Plate, and Flat BarC 478 Specification for Precast Reinforced Concrete Man-hole SectionsC 822 Terminology Relating to Concrete Pipe and
9、 RelatedProductsC 913 Specification for Precast Concrete Water and Waste-water StructuresD 395 Test Methods for Rubber PropertyCompressionSetD 412 Test Methods for Vulcanized Rubber and Thermo-plastic ElastomersTensionD 471 Test Method for Rubber PropertyEffect of LiquidsD 543 Practices for Evaluati
10、ng the Resistance of Plastics toChemical ReagentsD 573 Test Method for RubberDeterioration in an AirOvenF 624 Guide for Evaluation of Thermoplastic PolyurethaneSolids and Solutions for Biomedical ApplicationsD 883 Terminology Relating to PlasticsD 1149 Test Methods for Rubber DeteriorationCrackingin
11、 an Ozone Controlled EnvironmentD 1566 Terminology Relating to RubberD 2137 Test Methods for Rubber PropertyBrittlenessPoint of Flexible Polymers and Coated FabricsD 2240 Test Method for Rubber PropertyDurometerHardness1This specification is under the jurisdiction of ASTM Committee C13 onConcrete Pi
12、pe and is the direct responsibility of Subcommittee C13.06 on Manholesand Specials.Current edition approved March 1, 2008. Published April 2008. Originallyapproved in 2003. Last previous edition approved in 2007 as C 1478M 07.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orco
13、ntact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.NOTE 2For more infor
14、mation about wastewater structures, see Speci-fication C 913.3. Terminology3.1 Definitions:3.1.1 Terms relating to plastics and rubber shall be asdefined in Terminologies D 883 and D 1566, respectively.3.1.2 Terms relating to precast concrete pipe, manholes, andrelated products shall be as defined i
15、n Terminology C 822.3.2 Definitions of Terms Specific to This Standard:3.2.1 connectorthe entire assembly, including resilientseals and metallic or nonmetallic mechanical devices, if any,used therein.3.2.2 lateralthe small diameter pipe connected to themain line pipe.3.2.3 pipethe inlet or outlet pi
16、pe connected to the man-hole.3.2.4 pipe stuba short section of pipe installed in thestructure as an inlet or outlet pipe, for future connection.4. Materials and Manufacture4.1 All materials shall conform to the following require-ments:4.1.1 Resilient materials for connectors and filler rings shallbe
17、 manufactured from natural or synthetic rubber and shallconform to the requirements prescribed in Table 1. If a spliceis used in the manufacture of the seal, its strength shall be suchthat the seal shall withstand a 180 bend with no visibleseparation.4.2 Mechanical DevicesExpansion rings, tension ba
18、nds,and take-up devices used for mechanically compressing theresilient portion of the connector against the pipe or stormsewer structure shall be made from a material or materials incombination that will ensure durability, strength, resistance tocorrosion, and have properties that will ensure contin
19、uedresistance to leakage. All metallic mechanical devices, includ-ing castings and bolt assemblies used to mechanically deformresilient materials, shall be constructed of corrosion resistantmaterials meeting the physical properties and chemical com-position requirements of Specifications A 493 and A
20、 666, Type302 through Type 316.NOTE 3Experience has shown that successful performance of thisproduct depends on the type of bedding and backfill and the care in thefield installation of the manhole storm sewer structure and connectingpipes. The owner is cautioned to require inspection at the constru
21、ction site.5. Principles of Design5.1 The design of the connector shall be such that positiveseal is accomplished at two locations: (1) between the connec-tor and the storm sewer structure wall and (2) between theconnector and the pipe. The seal between the connector and thestorm sewer structure wal
22、l shall be made by either mechanicalmeans, compression of the resilient material between theoutside surface of the pipe and the pipe opening in the stormsewer structure wall, or by casting the connector integrallywith the storm sewer structure wall. The seal between theconnector and the pipe shall b
23、e made by mechanical means orby compression of the resilient material against the outside ofthe pipe. Resilient filler rings are not prohibited from beingused between the pipe and the connector to provide a seal.Whichever design is used, it shall be capable of maintaining aresilient, hydrostatic sea
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1478M2008STANDARDSPECIFICATIONFORSTORMDRAINRESILIENTCONNECTORSBETWEENREINFORCEDCONCRETESTORMSEWERSTRUCTURESPIPESANDLATERALSMETRICPDF

链接地址:http://www.mydoc123.com/p-464791.html