ASTM C1459-2004(2014) Standard Specification for Performance of Non-Asbestos Fiber-Reinforced Cement Shake Shingle and Slate Roofing Systems《无石棉纤维增强水泥盖屋板 屋顶板和屋面石板系统的性能的标准规格》.pdf
《ASTM C1459-2004(2014) Standard Specification for Performance of Non-Asbestos Fiber-Reinforced Cement Shake Shingle and Slate Roofing Systems《无石棉纤维增强水泥盖屋板 屋顶板和屋面石板系统的性能的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1459-2004(2014) Standard Specification for Performance of Non-Asbestos Fiber-Reinforced Cement Shake Shingle and Slate Roofing Systems《无石棉纤维增强水泥盖屋板 屋顶板和屋面石板系统的性能的标准规格》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1459 04 (Reapproved 2014)Standard Specification forPerformance of Non-Asbestos Fiber-Reinforced CementShake, Shingle, and Slate Roofing Systems1This standard is issued under the fixed designation C1459; the number immediately following the designation indicates the year oforiginal adop
2、tion or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers the performance of non-asbestos, fiber-reinfor
3、ced cement shake, shingle, and slateroofing systems that are of uniform or nonuniform thicknessand texture.1.2 This specification does not include details of productinstallation and workmanship. The manufacturers installationinstructions shall be referred to for details such as slope,interlayment, u
4、nderlayment, sheathing requirements, exposure,fasteners, and repair or replacement instructions.1.3 This specification does not address requirements forindividual shake, shingle, and slate products, which are cov-ered in Specification C1225 and C1530.1.4 The tests contained in this specification are
5、 intended asqualification tests for a roofing system. Changes in productformulation, design, or manufacturing process beyond theranges allowed in the manufacturers quality controlspecifications, shall require subsequent system retesting orwritten concurrence by an independent testing agency that the
6、changes in formulation, design, or manufacturing process willnot be detrimental to system performance.1.5 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not con
7、sidered standard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to us
8、e.2. Referenced Documents2.1 ASTM Standards:2C1154 Terminology for Non-Asbestos Fiber-Reinforced Ce-ment ProductsC1185 Test Methods for Sampling and Testing Non-Asbestos Fiber-Cement Flat Sheet, Roofing and SidingShingles, and ClapboardsC1225 Specification for Fiber-Cement Roofing Shingles,Shakes, a
9、nd SlatesC1530 Specification for Non-Asbestos Fiber-Cement Roof-ing Shakes, Shingles, and Slates with Designed VaryingProfiles and ThicknessesE108 Test Methods for Fire Tests of Roof Coverings3. Terminology3.1 DefinitionsRefer to Terminology C1154.4. Significance and Use4.1 This specification addres
10、ses key performance aspects offiber-reinforced cement roofing systems. Aspects of perfor-mance such as aesthetics, hail resistance, wind resistance,wind-driven rain resistance, and items referenced in 1.2 are notaddressed in this specification. Additional properties, whichmay influence system perfor
11、mance, are addressed in Specifi-cations C1225 and C1530.5. Performance Requirements5.1 Installed Strength TestThe failure loads for the equi-librium and wet specimens shall be as required in Table 1 whentested in accordance with Section 6.5.2 Installed Weight TestDetermine the weight in accor-dance
12、with Section 7.1This specification is under the jurisdiction of ASTM Committee C17 onFiber-Reinforced Cement Productsand is the direct responsibility of SubcommitteeC17.02 on Non-Asbestos Fiber Cement Products.Current edition approved June 1, 2014. Published June 2014. Originallyapproved in 2000. La
13、st previous edition approved in 2009 as C1459 04 (2009).DOI: 10.1520/C1459-04R14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page
14、 onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.3 Accelerated Aging (Wet/Dry Cycling Test)There shallbe no signs of additional damage or cracking when examinedunder 5 magnification, and the ratio of strength (R)
15、shall be atleast 0.90, when tested in accordance with Section 8.5.4 Accelerated Aging (Heat/Rain Test)Report any dam-age or structural alteration caused by the effect of stressesaround the fasteners that attach the fiber-reinforced cementproducts when tested in accordance with the section onHeat/Rai
16、n Roof Structures in Test Methods C1185.5.5 Fire-Resistant Roof TestWhere a specified level ofinstalled roofing system fire resistance is required, testing shallbe conducted in accordance with Test Methods E108 with theresults reported in accordance with the provisions describedwithin this specifica
17、tion.6. Strength Test Method6.1 Significance and UseThis test method simulates staticflexural loads.6.2 Preparation of Test Specimens:6.2.1 Test Specimen ConstructionFor each specimen builda test deck of nominal 2 by 4-in. (50 by 100-mm) runnersspaced a minimum of 16 in. (400 mm) on center. Installn
18、ominal 1 by 6-in. (25 by 150-mm) sheathing boards across therunners; provide 512-in. (140-mm) spaces between the sheath-ing boards. Solid sheathing is permitted to replace the spacedsheathing boards when testing roofing products which arelimited to installation over solid sheathing. Solid sheathingm
19、aterial shall be as specified in the manufacturers publishedinstallation instructions. Roofing products (a minimum of 3courses) are to be installed on the sheathing in a manneridentical to field practices, with maximum weather exposureand side spacing (keyway). The tested assembly is permitted toinc
20、lude underlayment or interlayment, or both, fasteners, andstarter course or cant strip. The maximum width of the testspecimen is not limited.6.2.2 Conditioning:6.2.2.1 EquilibriumPlace fully constructed specimens in acontrolled atmosphere of 73 6 4F (23 6 2C) and 50 6 5%relative humidity for 72 h in
21、 such a way that all faces areadequately ventilated. When the test specimens are removedfrom the controlled environment for testing, the testing shall beperformed within 30 min.6.2.2.2 WetImmerse fully constructed specimens in waterat a temperature of 73 6 4F (23 6 2C) for not less than 48h. Test th
22、e specimens within 30 min of removal from water.6.3 Test Procedure:6.3.1 Load test specimens at the mid-span of the roofingproducts between the spaced sheathing by a nominal 2 by 4-in.(50 by 100-mm) by 12-in. (300-mm) long wood loading beamplaced with the nominal 4-in. width in contact with thespeci
23、men surface. Laterally, center the loading beam on theroof covering unit width or on the keyway between roofingproducts whichever, at the discretion of the testing laboratory,will yield lower values. Report tested locations. See Fig. 1.TABLE 1 Failure LoadsProduct Type Minimum Load, lbf (N)Condition
24、ed ImmersedAverageAIndividualBAverageAIndividualBInitial Ultimate Initial Ultimate Initial Ultimate Initial UltimateFlat shake,shingle, or slate225 (1k) 300 (1.33k) 200 (0.89k) 250 (1.11k) 215 (0.96k) 250 (1.11k) 200 (0.89k) 225 (1k)AAverage value of five consecutive tests.BMinimum individual test v
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC145920042014STANDARDSPECIFICATIONFORPERFORMANCEOFNONASBESTOSFIBERREINFORCEDCEMENTSHAKESHINGLEANDSLATEROOFINGSYSTEMS

链接地址:http://www.mydoc123.com/p-464731.html