ASTM C1448 C1448M-2005(2014) Standard Specification for Non-Asbestos Fiber-Cement Conduit《非石棉纤维水泥导管的标准规格》.pdf
《ASTM C1448 C1448M-2005(2014) Standard Specification for Non-Asbestos Fiber-Cement Conduit《非石棉纤维水泥导管的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1448 C1448M-2005(2014) Standard Specification for Non-Asbestos Fiber-Cement Conduit《非石棉纤维水泥导管的标准规格》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1448/C1448M 05 (Reapproved 2014)Standard Specification forNon-Asbestos Fiber-Cement Conduit1This standard is issued under the fixed designation C1448/C1448M; the number immediately following the designation indicates theyear of original adoption or, in the case of revision, the year of
2、 last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers non-asbestos fiber-cementconduit for use in electric-power systems and communicationsystems
3、. The service is for both underground and exposedconditions.1.2 The values stated in either inch-pound units or SI unitsare to be regarded separately as standard. Within the text, theSI units are shown in brackets. The values stated in eachsystem are not exact equivalents; therefore each system shal
4、lbe used independently of the other. Combining values from thetwo systems may result in nonconformance with the specifi-cation.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish a
5、ppro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C150 Specification for Portland CementC497 Test Methods for Concrete Pipe, Manhole Sections, orTileC500 Test Methods for Asbestos-Cement PipeC595
6、 Specification for Blended Hydraulic CementsC1154 Terminology for Non-Asbestos Fiber-Reinforced Ce-ment Products2.2 Military Standard:MIL-STD-129 Marking for Shipment and Storage32.3 Federal Standard:No. 123 Marking for Domestic Shipment (Civilian Agen-cies)32.4 ISO Standards:ISO 390 Products in Fib
7、re Reinforced CementSamplingand Inspection4ISO 28591 Sampling Procedures for Inspection by Attri-butes Part 1: Sampling Schemes Indexed by AcceptanceQuality Limit (AQL) for Lot-by-Lot Inspection4ISO 3951 Sampling Procedures and Charts for Inspection byVariables for Percent Nonconforming42.5 Other St
8、andards:Uniform Freight Classification Rules5National Motor Freight Classification Rules63. Terminology3.1 DefinitionsRefer to Terminology C1154.3.1.1 conduit, nfiber-cement pipe used to protect wires forelectric-power or communication systems, for both under-ground and exposed situations.3.1.2 coup
9、lingcomponent made from a larger diameterpipe of the same type or Type II and of the same class or ahigher class, or produced otherwise to yield at least equalperformance, for joining fiber-cement pipe that when properlyinstalled, forms a silt-tight joint, allows alignment correctionsand slight chan
10、ges in direction, and provides an assembledjoint equivalent in serviceability and strength to the pipesections.3.1.3 fittingsfittings such as adapters, reducers, increasers,bends, and bell ends, for use in laying fiber-cement conduit asdescribed in Section 5 and made to such dimensions as willprovid
11、e equivalent strength and silt-tight joints when as-sembled with the conduit.4. Classification4.1 The classes of conduit shall be as follows:4.1.1 Class BIntended for use encased in concrete afterinstallation, and4.1.2 Class CIntended for use without concreteencasement, or for exposed services.1This
12、 specification is under the jurisdiction of ASTM Committee C17 onFiber-Reinforced Cement Productsand is the direct responsibility of SubcommitteeC17.02 on Non-Asbestos Fiber Cement Products.Current edition approved Dec. 1, 2014. Published December 2014. Originallyapproved in 1999. Last previous edit
13、ion approved in 2010 as C1448/C1448M 05(2010). DOI: 10.1520/C1448_C1448M-05R14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page o
14、nthe ASTM website.3Available from Standardization Documents Order Desk, Bldg. 4 Section D, 700Robbins Avenue, Philadelphia, PA 19111-5094.4Available from International Organization for Standardization (ISO), 1 rue deVaremb, Case postale 56, CH-1211, Geneva 20, Switzerland.5Available from the Uniform
15、 Classification Commission, Room 1106, 222 S.Riverside Plaza, Chicago, IL 60606.6Available from National Motor Freight Inc., 1616 P St., NW, Washington, DC20036.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.2 The types of conduit
16、shall be known as Type I and TypeII corresponding to the chemical requirements given in SectionS3 of this specification. For a more thorough understandingand as a guide to the chemical resistance of fiber-cementconduit, reference is made to Test Methods C500.NOTE 1There are no chemical requirements
17、for Type I Conduit.NOTE 2To assist the purchaser in choosing the type of conduit mostsuitable for his use, the following descriptions of usage may be consid-ered:4.2.1 Type IFor use where nonaggressive water and soil ofmoderate sulfate content are expected to come in contact withthe conduit, and4.2.
18、2 Type IIFor use where moderately aggressive wateror water and soil of high sulfate content, or both, are expectedto come in contact with the conduit.4.3 The conduit shall be furnished in 1.5, 2, 3, 4, 5, and 6-in.40, 50, 75, 100, and 150 mm nominal sizes and shall have acircular cross section.5. Ma
19、terials and Manufacture5.1 Fiber-cement conduit shall be composed of an intimatemixture of an inorganic hydraulic binder (see SpecificationC150) or a calcium silicate binder (see Specification C595)formed by the chemical reaction of a siliceous material and acalcareous material reinforced by organic
20、 fibers, inorganicnon-asbestos fibers, or both. Process aids, fillers and pigmentswhich are compatible with fiber-reinforced cement are notprohibited from being added. All material shall be of laminarconstruction formed under pressure to a homogeneous struc-ture and cured to meet the physical and ch
21、emical requirementsof this specification.6. Mechanical Properties6.1 Flexural Strength:6.1.1 Each 10 or 13 ft 3048 or 3962 mm standard lengthand each 9.5 ft 2896 mm or longer random length conduitshall have sufficient flexural strength to withstand, withoutfailure, the total load prescribed in Table
22、 1, when tested inaccordance with 6.1.1.1.6.1.1.1 The specimen shall be mounted longitudinally on“V” blocks, preferably of hard wood or of steel, 2 in. 50 mmlong, 120 2 rad angle of “V,” faces 5 by 2 in. 130 by 50mm, and the load applied through a rectangular block, 2 in.50 mm in width, at the cente
23、r of the span. The spans betweenthe faces of supporting blocks shall be as given in Table 1 forthe particular class of conduit. The breaking loads, the averageof at least two specimens from each length, shall not be lessthan those given in Table 1 for the particular class of conduit.6.2 Crushing Str
24、engthCrushing tests shall be conductedbefore shipment. Test Specimens 12 in. 300 mm long cutfrom an unmachined portion of pipe shall be tested in accor-dance with the appropriate section of Test Methods C497.7. Dimensions, Mass, and Tolerances7.1 The average inside diameter measured at the end of th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1448C1448M20052014STANDARDSPECIFICATIONFORNONASBESTOSFIBERCEMENTCONDUIT 石棉 纤维 水泥 导管 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-464705.html