ASTM C138 C138M-2007 Standard Test Method for Density (Unit Weight) Yield and Air Content (Gravimetric) of Concrete.pdf
《ASTM C138 C138M-2007 Standard Test Method for Density (Unit Weight) Yield and Air Content (Gravimetric) of Concrete.pdf》由会员分享,可在线阅读,更多相关《ASTM C138 C138M-2007 Standard Test Method for Density (Unit Weight) Yield and Air Content (Gravimetric) of Concrete.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 138/C 138M 07American Association StateHighway and Transportation Officials StandardAASHTO No.: T121Standard Test Method forDensity (Unit Weight), Yield, and Air Content (Gravimetric)of Concrete1This standard is issued under the fixed designation C 138/C 138M; the number immediately f
2、ollowing the designation indicates the yearof original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been a
3、pproved for use by agencies of the Department of Defense.1. Scope*1.1 This test method covers determination of the density(see Note 1) of freshly mixed concrete and gives formulas forcalculating the yield, cement content, and air content of theconcrete. Yield is defined as the volume of concrete pro
4、ducedfrom a mixture of known quantities of the component materi-als.1.2 The values stated in either inch-pound or SI units shallbe regarded separately as standard. The SI units are shown inbrackets. The values stated might not be exact equivalents;therefore each system must be used independently of
5、the other.NOTE 1Unit weight was the previous terminology used to describethe property determined by this test method, which is mass per unitvolume.1.3 The text of this test method references notes andfootnotes that provide explanatory information. These notesand footnotes (excluding those in tables)
6、 shall not be consid-ered as requirements of this test method.2. Referenced Documents2.1 ASTM Standards:2C 29/C 29M Test Method for Bulk Density (“Unit Weight”)and Voids in AggregateC 150 Specification for Portland CementC 172 Practice for Sampling Freshly Mixed ConcreteC 188 Test Method for Density
7、 of Hydraulic CementC 231 Test Method for Air Content of Freshly MixedConcrete by the Pressure Method3. Terminology3.1 Symbols:A = air content (percentage of voids) in the concreteC = actual cement content, lb/yd3or kg/m3Cb= mass of cement in the batch, lb or kgD = density (unit weight) of concrete,
8、 lb/ft3or kg/m3M = total mass of all materials batched, lb or kg (see Note3)Mc= mass of the measure filled with concrete, lb or kgMm= mass of the measure, lb or kgRy= relative yieldT = theoretical density of the concrete computed on anairfree basis, lb/ft3or kg/m3(see Note 2)Y = yield, volume of con
9、crete produced per batch, yd3orm3Yd= volume of concrete which the batch was designed toproduce, yd3or m3Yf= volume of concrete produced per batch, ft3V = total absolute volume of the component ingredientsin the batch, ft3or m3Vm= volume of the measure, ft3or m3NOTE 2The theoretical density is, custo
10、marily, a laboratory determi-nation, the value for which is assumed to remain constant for all batchesmade using identical component ingredients and proportions. It is calcu-lated from the following equation:T 5 M/V (1)The absolute volume of each ingredient in cubic feet is equal to thequotient of t
11、he mass of that ingredient divided by the product of itsspecific gravity times 62.4. The absolute volume of each ingredient incubic metres is equal to the mass of the ingredient in kilograms divided by1000 times its specific gravity. For the aggregate components, the bulkspecific gravity and mass sh
12、ould be based on the saturated, surface-drycondition. For cement, the actual specific gravity should be determined byTest Method C 188. A value of 3.15 may be used for cements manufac-tured to meet the requirements of Specification C 150.NOTE 3The total mass of all materials batched is the sum of th
13、emasses of the cement, the fine aggregate in the condition used, the coarseaggregate in the condition used, the mixing water added to the batch, andany other solid or liquid materials used.1This test method is under the jurisdiction of ASTM Committee C09 onConcrete and Concrete Aggregates and is the
14、 direct responsibility of SubcommitteeC09.60 on Testing Fresh Concrete.Current edition approved Aug. 15, 2007. Published September 2007. Originallyapproved in 1938. Last previous edition approved in 2001 as C 138/C 138M 01a.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcont
15、act ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West
16、 Conshohocken, PA 19428-2959, United States.4. Apparatus4.1 BalanceA balance or scale accurate to 0.1 lb 45 g orto within 0.3 % of the test load, whichever is greater, at anypoint within the range of use. The range of use shall beconsidered to extend from the mass of the measure empty tothe mass of
17、the measure plus its contents at 160 lb/ft32600kg/m3.4.2 Tamping RodA round, straight steel rod,58 in. 16mm in diameter and approximately 24 in. 600 mm in length,having the tamping end rounded to a hemispherical tip thediameter of which is58 in.4.3 Internal VibratorInternal vibrators may have rigid
18、orflexible shafts, preferably powered by electric motors. Thefrequency of vibration shall be 7000 vibrations per minute orgreater while in use. The outside diameter or the side dimen-sion of the vibrating element shall be at least 0.75 in. 19 mmand not greater than 1.50 in. 38 mm. The length of the
19、shaftshall be at least 24 in. 600 mm.4.4 MeasureAcylindrical container made of steel or othersuitable metal (see Note 4). The minimum capacity of themeasure shall conform to the requirements of Table 1 based onthe nominal size of aggregate in the concrete to be tested. Allmeasures, except for measur
20、ing bowls of air meters which arealso used for Test Method C 138/C 138M tests, shall conformto the requirements of Test Method C 29/C 29M. When mea-suring bowls of air meters are used, they shall conform to therequirements of Test Method C 231, and shall be calibrated forvolume as described in Test
21、Method C 29/C 29M. The top rimof the air meter bowls shall be smooth and plane within 0.01 in.0.3 mm (see Note 5).NOTE 4The metal should not be readily subject to attack by cementpaste. However, reactive materials such as aluminum alloys may be usedin instances where as a consequence of an initial r
22、eaction, a surface filmis rapidly formed which protects the metal against further corrosion.NOTE 5The top rim is satisfactorily plane if a 0.01-in. 0.3-mm feelergage cannot be inserted between the rim and a piece of14-in. 6-mm orthicker plate glass laid over the top of the measure.4.5 Strike-Off Pla
23、teA flat rectangular metal plate at least14 in. 6 mm thick or a glass or acrylic plate at least12 in. 12mm thick with a length and width at least 2 in. 50 mmgreater than the diameter of the measure with which it is to beused. The edges of the plate shall be straight and smooth withina tolerance of11
24、6 in. 2 mm.4.6 MalletA mallet (with a rubber or rawhide head)having a mass of 1.25 6 0.50 lb 600 6 200 g for use withmeasures of 0.5 ft314 L or smaller, and a mallet having amass of 2.25 6 0.50 lb 1000 6 200 g for use with measureslarger than 0.5 ft3.5. Sample5.1 Obtain the sample of freshly mixed c
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC138C138M2007STANDARDTESTMETHODFORDENSITYUNITWEIGHTYIELDANDAIRCONTENTGRAVIMETRICOFCONCRETEPDF
链接地址:http://www.mydoc123.com/p-464412.html