ASTM C1340-2004 Standard Practice for Estimation of Heat Gain or Loss Through Ceilings Under Attics Containing Radiant Barriers by Use of a Computer Program《通过计算机程序的使用对通过含辐射阻碍物的顶楼天.pdf
《ASTM C1340-2004 Standard Practice for Estimation of Heat Gain or Loss Through Ceilings Under Attics Containing Radiant Barriers by Use of a Computer Program《通过计算机程序的使用对通过含辐射阻碍物的顶楼天.pdf》由会员分享,可在线阅读,更多相关《ASTM C1340-2004 Standard Practice for Estimation of Heat Gain or Loss Through Ceilings Under Attics Containing Radiant Barriers by Use of a Computer Program《通过计算机程序的使用对通过含辐射阻碍物的顶楼天.pdf(21页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1340 04Standard Practice forEstimation of Heat Gain or Loss Through Ceilings UnderAttics Containing Radiant Barriers by Use of a ComputerProgram1This standard is issued under the fixed designation C 1340; the number immediately following the designation indicates the year oforiginal a
2、doption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the estimation of heat gain or lossthrough ceil
3、ings under attics containing radiant barriers by useof a computer program. The computer program included as anadjunct to this practice provides a calculational procedure forestimating the heat loss or gain through the ceiling under anattic containing a truss or rafter mounted radiant barrier. Thepro
4、gram also is applicable to the estimation of heat loss or gainthrough ceilings under an attic without a radiant barrier. Thisprocedure utilizes hour-by-hour weather data to estimate thehour-by-hour ceiling heat flows. The interior of the housebelow the ceiling is assumed to be maintained at a consta
5、nttemperature. At present, the procedure is applicable to sloped-roof attics with rectangular floor plans having an unshadedgabled roof and a horizontal ceiling. It is not applicable tostructures with flat roofs, vaulted ceilings, or cathedral ceilings.The calculational accuracy also is limited by t
6、he quality ofphysical property data for the construction materials, princi-pally the insulation and the radiant barrier, and by the qualityof the weather data.1.2 Under some circumstances, interactions between radiantbarriers and HVAC ducts in attics can have a significant effecton the thermal perfo
7、rmance of a building. Ducts are included inan extension of the computer model given in the appendix.1.3 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.2. Referenced Documents2.1 ASTM Standards:2C 168 Terminology Relati
8、ng to Thermal Insulation2.2 ANSI Standards:X3.5 Flow Chart Symbols and Their Usage in InformationProcessing3X3.9 Standard for Fortran Programming Language32.3 ASTM Adjuncts:Computer Program for Estimation of Heat Gain or Lossthrough Ceilings Under Attics Containing Radiant Barri-ers43. Terminology3.
9、1 DefinitionsFor definitions of terms used in this prac-tice, refer to Terminology C 168.3.2 SymbolsSymbols will be introduced and defined inthe detailed description of the development.4. Summary of Practice4.1 The procedures used in this practice are based on thethermal response factor method for c
10、alculating dynamic heatconduction through multilayer slabs (1,2),5along with a modelfor convective and radiative heat exchanges inside and outsidethe attic.4.2 The operation of the computer program involves thefollowing steps:4.2.1 Response FactorsA separate computer programmust be used to calculate
11、 the thermal response factors of thesolid materials surrounding the attic. Input to this programwould consist of the thermal conductivity, specific heat,density, and thickness of each layer, or the thermal resistance ofthe layer if it has negligible density, and the fraction of thecross-sectional ar
12、ea occupied by the framing. Output of such aprogram would be a set of response factors for use as input tothe main program. The adjunct to this practice contains datafiles with response factors for several typical attic construc-tions.1This practice is under the jurisdiction of ASTM Committee C16 on
13、 ThermalInsulation and is the direct responsibility of Subcommittee C16.21 on ReflectiveInsulation.Current edition approved Sept. 1, 2004. Published October 2004. Originallyapproved in 1999. Last previous edition approved in 1999 as C 1340 99.2For referenced ASTM standards, visit the ASTM website, w
14、ww.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.4Available
15、from ASTM Headquarters. Request Adjunct: ADJC1340.5The boldface numbers in parentheses refer to the list of references at the end ofthis standard.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.2.2 Data Input to the Main ProgramThi
16、s input includesthe response factors, total hemispherical emittances of theinside and outside surfaces of the attic envelope, solar absorp-tances of the outside surfaces of the attic envelope, length andwidth of the attic, slopes of the two roof sections, distancebetween attic floor and roof at edge
17、 of attic, orientation ofhouse, vent areas and type of vents, water vapor permeances ofattic surfaces, area of exposed wood inside attic, mass of woodin attic, initial moisture content of wood in attic, rate ofexfiltration of air from house into attic space, latitude andlongitude, time zone indicato
18、r, solar reflectance of the ground,indoor temperature, and indoor humidity.4.2.3 AnalysisUsing hourly weather data consisting ofoutdoor temperature and humidity ratio, atmospheric pressure,total horizontal and direct solar radiation, wind speed anddirection, cloud amount, cloud type, and atmospheric
19、 clearnessnumber, the computer program calculates the inside andoutside temperatures of the attic envelope and the temperatureof the air inside the attic. Using these temperatures, theprogram calculates the heat flux through the ceiling.4.2.4 OutputThe hourly heat flux through the ceiling iswritten
20、to a file which can be used for further processing, suchas seasonal or annual heat gains or losses.5. Significance and Use5.1 Manufacturers of radiant barriers express the perfor-mance of their products in terms of the total hemisphericalemittance. The purpose of a radiant barrier is to decrease the
21、radiation heat transfer across the attic air space, and hence, todecrease the heat loss or gain through the ceiling below theattic. The amount of decrease in heat flow will depend upon anumber of factors, such as weather conditions, amount of massor reflective insulation in the attic, solar absorpta
22、nce of theroof, geometry of the attic and roof, and amount and type ofattic ventilation. Because of the infinite combinations of thesefactors, it is not practical to publish data for each possible case.5.2 The calculation of heat loss or gain of a systemcontaining radiant barriers is mathematically
23、complex, andbecause of the iterative nature of the method, it is best handledby computers.5.3 Computers are now widely available to most producersand consumers of radiant barriers to permit the use of thispractice.5.4 The user of this practice may wish to modify the datainput to represent accurately
24、 the structure. The computerprogram also may be modified to meet individual needs. Also,additional calculations may be desired, for example, to sum thehourly heat flows in some fashion to obtain estimates ofseasonal or annual energy usages. This might be done using thehourly data as inputs to a whol
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC13402004STANDARDPRACTICEFORESTIMATIONOFHEATGAINORLOSSTHROUGHCEILINGSUNDERATTICSCONTAININGRADIANTBARRIERSBYUSEOFACOMPUTERPROGRAM

链接地址:http://www.mydoc123.com/p-464292.html