《ASTM C1339-2002(2012) Standard Test Method for Flowability and Bearing Area of Chemical-Resistant Polymer Machinery Grouts《耐化学性聚合物机械灰浆的可流动性和承重区的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1339-2002(2012) Standard Test Method for Flowability and Bearing Area of Chemical-Resistant Polymer Machinery Grouts《耐化学性聚合物机械灰浆的可流动性和承重区的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1339 02 (Reapproved 2012)Standard Test Method forFlowability and Bearing Area of Chemical-Resistant PolymerMachinery Grouts1This standard is issued under the fixed designation C1339; the number immediately following the designation indicates the year oforiginal adoption or, in the case
2、 of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the measure of flowability ofchemical-resistant polymer machinery gr
3、outs as evaluated in a2-in. (5-cm) or 1-in. (2.5-cm) pour thickness. The test methodprovides for the assessment of upper surface plate contact area(bearing area). These grouts will typically be two- or three-component formulations that may be used for installationswhere grout thickness will range fr
4、om 1 to 6 in. (2.5 to 15 cm)underneath the base or plates being grouted.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.3 This stan
5、dard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 A
6、STM Standards:2C904 Terminology Relating to Chemical-Resistant Nonme-tallic Materials3. Terminology3.1 DefinitionsFor definition of terms used in this testmethod, see Terminology C904.4. Summary of Test Method4.1 Polymer machinery grout of a flowable consistency ispoured into a hopper at one end of
7、a shallow plastic trough witha clear plastic cover plate.4.2 A movable gate is raised, allowing the grout to flowfrom the hopper into the trough. The times for the grout to firstcontact the end plate and to establish full length contact withthe top cover plate are recorded and used as indices offlow
8、ability.4.3 After the grout hardens, the mold and top plate areremoved. The top surface of the grout is wire brushed to exposeany surface air bubbles or voids, and a visual estimate is madeof the percentage of grout top surface area that is in contactwith the plate. Visual guides are provided for co
9、mparativepurposes (see Fig. 1 and Fig. 2).5. Significance and Use5.1 Chemical-resistant polymer machinery grouts are usedto provide precision support for machinery or equipment.5.2 The machinery or equipment or support bases or plates,or combination thereof, are positioned to the precise elevationan
10、d location required. The bases or plates are typically placedon prepared foundations and supported on temporary shims orsupport bolts (jack screws). Forms are installed to contain theflowable grout. The grout is poured around the perimeter insuch a manner as to allow the grout to flow around and und
11、erthe equipment base or plates. The grout subsequently hardensto provide a strong rigid support layer capable of withstandingthe stresses transferred by the equipment to the foundation.5.3 In addition to the required physical properties of thegrout, the flow and bearing area achieved are importantco
12、nsiderations for effective grout installation. The two charac-teristics measured by this test method are flow and bearingarea.5.4 The flow test simulates typical application conditionsfor a flowable polymer machinery grout. It may be used toevaluate the suitability of a particular grout for a specif
13、icapplication, to compare the flowability and bearing area of twoor more grouts, or to evaluate the effects of formulationchanges, temperature, mixing techniques, or other factors onflowability.5.5 The estimated amount of upper grout surface contact inpercent can be used to compare two or more grout
14、s or show theeffects of temperature, formulation changes, or other factors onbearing area. Because of the limited accuracy in estimating the1This test method is under the jurisdiction of ASTM Committee C03 onChemical-Resistant Nonmetallic Materialsand is the direct responsibility of Sub-committee C0
15、3.01 on Mortars and Carbon Brick.Current edition approved Aug. 1, 2012. Published September 2012. Originallyapproved in 1996. Last previous edition approved in 2008 as C1339 02 (2008).DOI: 10.1520/C1339-02R12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Custom
16、er Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1percent of contact, a limited set of r
17、esults is suggested (see9.9.1). Visual guides are provided for comparative purposes(see Fig. 1 and Fig. 2).6. Apparatus6.1 Flow Box, a plastic flow box as shown in Fig. 3 withdemountable sides and ends and a sliding gate, having atransparent cover plate of rigid polycarbonate plastic.6.2 Stopwatch,
18、of normal commercial accuracy, readable toat least 1 s.6.3 Thermometer or Thermocouple , suitable for insertioninto the grout while still plastic.6.4 Mixer, a commercial mixing device that is able to rotatea 5-gal metal or plastic pail with a stationary mixing blade tostir the grout mix. Typical ope
19、rating speed is 30 to 100 rpm(see Fig. 4).7. Preparation of Apparatus7.1 Prewax all the component parts of the flow box withpaste wax and buff before assembly to ensure that the groutdoes not adhere. The top cover plate shall not be waxed sincethe wax may have an adverse effect on the bearing area.7
20、.2 Assemble the box as follows:7.2.1 Place the bottom plate on a flat work surface with thegrooves facing upward.7.2.2 Insert the left and right side plates of the box into thebottom plate with the grooved sides facing inward.7.2.3 Slide the back plate down between the slanted groovesof the left and
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC133920022012STANDARDTESTMETHODFORFLOWABILITYANDBEARINGAREAOFCHEMICALRESISTANTPOLYMERMACHINERYGROUTS

链接地址:http://www.mydoc123.com/p-464285.html