ASTM C1321-2014 Standard Practice for Installation and Use of Interior Radiation Control Coating Systems &40 IRCCS&41 in Building Construction《建筑物内部辐射控制涂层系统(IRCCS)安装和使用的标准操作规程》.pdf
《ASTM C1321-2014 Standard Practice for Installation and Use of Interior Radiation Control Coating Systems &40 IRCCS&41 in Building Construction《建筑物内部辐射控制涂层系统(IRCCS)安装和使用的标准操作规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1321-2014 Standard Practice for Installation and Use of Interior Radiation Control Coating Systems &40 IRCCS&41 in Building Construction《建筑物内部辐射控制涂层系统(IRCCS)安装和使用的标准操作规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1321 14Standard Practice forInstallation and Use of Interior Radiation Control CoatingSystems (IRCCS) in Building Construction1This standard is issued under the fixed designation C1321; the number immediately following the designation indicates the year oforiginal adoption or, in the c
2、ase of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice has been prepared for use by the designer,specifier, and applicator of IRCC
3、S (Interior Radiation ControlCoating Systems) for use in building construction. The scopecontains instructions related to the use and installation ofIRCCS, including a surface(s) having a far-infrared emittanceof 0.25 or less that is sprayed or painted.2Some examples thatthis practice is intended to
4、 address include: (1) low emittancesurfaces in vented building envelope cavities intended to retardradiant transfer across the vented airspace; (2) low emittancesurfaces at interior building surfaces intended to retard radianttransfer to or from building inhabitants; and (3) low emittancesurfaces at
5、 interior building surfaces intended to reduce radianttransfer to or from heating or cooling systems. See Fig. 1 andFig. 2 for typical applications.1.2 This practice covers the installation process from pre-installation inspection through post-installation. It does notcover the production of the Int
6、erior Radiation Control CoatingMaterials.1.3 This practice is not intended to replace the manufactur-ers installation instructions, but it shall be used in conjunctionwith such instructions. This practice is not intended to super-sede local, state, or federal codes.1.4 This practice assumes that the
7、 installer possesses a goodworking knowledge of the application codes and regulations,safety practices, tools, equipment, and methods necessary forthe installation of Interior Coating Materials. It also assumesthat the installer understands the fundamentals of buildingconstruction that affect the in
8、stallation of an IRCCS.1.5 When the installation or use of Interior RadiationControl Coating Materials, accessories, and systems posesafety or health problems, the manufacturer shall provide theuser appropriate current information regarding any knownproblems associated with the intended use of the p
9、roducts andshall also provide direction on protective measures to beemployed for safe utilization. The user shall establish appro-priate safety and health practices and determine the applicabil-ity of regulatory requirements prior to use.1.6 This standard does not purport to address all of thesafety
10、 concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific precau-tionary statements are contained in Sections 5 and 7.2. Refe
11、renced Documents2.1 ASTM Standards:3C168 Terminology Relating to Thermal InsulationC1371 Test Method for Determination of Emittance ofMaterials Near Room Temperature Using Portable Emis-sometersE84 Test Method for Surface Burning Characteristics ofBuilding MaterialsE96/E96M Test Methods for Water Va
12、por Transmission ofMaterials2.2 NFPA Standards:4NFPA 54 National Fuel Gas CodeNFPA 211 Standard for Chimneys, Fireplaces and Vents2.3 Other Documents:CPSC Product Safety Fact Sheet No. 18 “The Home Elec-trical System”53. Terminology3.1 DefinitionsFor definitions of terms used in thispractice, refer
13、to Terminology C168.3.2 Definitions of Terms Specific to This Standard:1This practice is under the jurisdiction of ASTM Committee C16 on ThermalInsulationand is the direct responsibility of Subcommittee C16.21 on ReflectiveInsulation.Current edition approved Feb. 1, 2014. Published March 2014. Origi
14、nallyapproved 1996. Last previous edition approved in 2009 as C132109. DOI:10.1520/C1321-14.2The as-manufactured emittance of Interior Radiation Control Coating product,as determined on a typical substrate, should be stated on the label (see 7.2.1).3For referenced ASTM standards, visit the ASTM webs
15、ite, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Available from National Fire Protection Association (NFPA), 1 BatterymarchPark, Quincy, MA 02169-7471, http:/ww
16、w.nfpa.org.5Available from Consumer Specialty ProductsAssociation (CSPA), 900 17th St.,NW, Suite 300, Washington, DC 20006, http:/www.cspa.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.2.1 applicatorthe person or persons who a
17、pply interiorreflective coating materials in buildings.3.2.2 conditioned spaceany space in a building that isserved by a heating or cooling system.3.2.3 Interior Radiation Control Coating Systems(IRCCS)a building construction consisting of a low emit-tance (0.25 or less) surface bounded by an open a
18、ir space. AnIRCCS is used for the sole purpose of limiting heat transfer byradiation and is not specifically intended to reduce heat transferby convection or conduction.3.2.4 open air spacea vented building cavity (forexample, a vented attic) or a large conditioned or uncondi-tioned building space.3
19、.2.5 DiscussionA large building space is defined as onewhose minimum dimension exceeds two feet.3.2.6 ownerthe person, partnership, corporation, agency,or other entity who owns the building in which the IRCCS isto be applied whether such ownership is by virtue of deed,contract, or any other instrume
20、nt for acquiring legal title underthe laws of the state in which the building is located.4. Significance and Use4.1 This practice recognizes that effectiveness, safety, anddurability of an IRCCS depends not only on the quality of thematerials, but also on the proper installation.4.2 Improper install
21、ation of an IRCCS will reduce itsthermal effectiveness, cause fire risks and other unsafeconditions, and promote deterioration of the structure in whichit is installed. Improper installation has the potential to createspecific hazards that include: heat buildup in recessed lightingfixtures, deterior
22、ation of failure of electrical wiringcomponents, and deterioration of wood structures and paintfailure due to moisture accumulation.4.3 This practice provides directions for the installation ofIRCCS materials in a safe and effective manner. Actualconditions in existing buildings will vary greatly.4.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC13212014STANDARDPRACTICEFORINSTALLATIONANDUSEOFINTERIORRADIATIONCONTROLCOATINGSYSTEMS40IRCCS41INBUILDINGCONSTRUCTION

链接地址:http://www.mydoc123.com/p-464220.html