ASTM C1278 C1278M-2007a(2011) Standard Specification for Fiber-Reinforced Gypsum Panel《纤维增强石膏镶板标准规格》.pdf
《ASTM C1278 C1278M-2007a(2011) Standard Specification for Fiber-Reinforced Gypsum Panel《纤维增强石膏镶板标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1278 C1278M-2007a(2011) Standard Specification for Fiber-Reinforced Gypsum Panel《纤维增强石膏镶板标准规格》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1278/C1278M 07a (Reapproved 2011)Standard Specification forFiber-Reinforced Gypsum Panel1This standard is issued under the fixed designation C1278/C1278M; the number immediately following the designation indicates theyear of original adoption or, in the case of revision, the year of la
2、st revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers fiber-reinforced gypsum pan-els described in 1.1.1-1.1.4.1.1.1 Interior Fiber-Reinforced Gyps
3、um Panels are de-signed to be used for walls, ceilings, or partitions and affordsa suitable surface to receive decoration.1.1.2 Water-Resistant Fiber-Reinforced Gypsum BackingPanels are designed primarily to be used as a base for theapplication of ceramic or plastic tile on walls or ceilings. Thispr
4、oduct is also suitable for decoration.1.1.3 Exterior Fiber-Reinforced Gypsum Sofft Panels aredesigned for use on exterior soffits and carport ceilings that arecompletely protected from contact with liquid water.1.1.4 Water-Resistant Exterior Fiber-Reinforced GypsumSheathing Panels are designed for u
5、se as sheathing on build-ings.1.1.5 Interior Fiber-Reinforced Gypsum UnderlaymentPanels are designed for use as a base for application of finishedflooring materials.1.1.6 Fiber-Reinforced Gypsum Board Panels are designedfor use in roofing systems.1.2 Specifications applicable to all fiber-reinforced
6、 gypsumpanels are located in Sections 1-4 and 11-13 except as modifiedby applicable product sections. Specifications applicable tospecific panels are located in the following sections:Interior Fiber-Reinforced Gypsum Panels 5Water-Resistant Fiber-Reinforced Gypsum Backing Panels 6Exterior Fiber-Rein
7、forced Gypsum Soffit Panels 7Water-Resistant Exterior Fiber-Reinforced Gypsum Sheathing Panels 8Interior Fiber-Reinforced Gypsum Underlayment Panels 9Fiber-Reinforced Gypsum Roof Board Panels 101.3 The values stated in either inch-pound units or SI(metric) are to be regarded separately as the standa
8、rd. Withinthe text, the SI units are shown in brackets. The values statedin each system shall be used independently of the other. Valuesfrom the two systems shall not be combined.1.4 The text of this specification references notes andfootnotes that provide explanatory material. These notes andfootno
9、tes shall not be considered as requirements of thestandard.2. Referenced Documents2.1 ASTM Standards:2C11 Terminology Relating to Gypsum and Related BuildingMaterials and SystemsC22/C22M Specification for GypsumC473 Test Methods for Physical Testing of Gypsum PanelProductsC645 Specification for Nons
10、tructural Steel Framing Mem-bersC1264 Specification for Sampling, Inspection, Rejection,Certification, Packaging, Marking, Shipping, Handling,and Storage of Gypsum Panel ProductsD1037 Test Methods for Evaluating Properties of Wood-Base Fiber and Particle Panel MaterialsE84 Test Method for Surface Bu
11、rning Characteristics ofBuilding MaterialsE96/E96M Test Methods for Water Vapor Transmission ofMaterialsE119 Test Methods for Fire Tests of Building Constructionand Materials3. Terminology3.1 DefinitionsDefinitions of terms shall be in accordancewith Terminology C11.3.1.1 nominal thickness, nthe man
12、ufacturer-stated frac-tional value of thickness of the gypsum panel product ex-pressed in decimal value to the nearest one-thousandth (0.001)of an inch.4. Materials and Manufacture4.1 Fiber-reinforced gypsum panels shall consist essentiallyof gypsum with fibers dispersed throughout.4.1.1 GypsumSpeci
13、fication C22/C22M.1This specification is under the jurisdiction of ASTM Committee C11 onGypsum and Related Building Materials and Systems and is the direct responsi-bility of Subcommittee C11.01 on Specifications and Test Methods for GypsumProducts.Current edition approved Dec. 1, 2011. Published Ju
14、ne 2012. Originallyapproved in 1994. Last previous edition approved in 2007 as C1278/C1278M 07a.DOI: 10.1520/C1278_C1278M-07AR11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume informati
15、on, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.1.2 FibersCellulose, derived from paper, paperboa
16、rdstock, wood, or other organic material.4.2 The back surface of foil-backed fiber-reinforced gypsumpanels shall in addition be covered with aluminum foil.4.3 Water-resistant fiber-reinforced gypsum panels shall betreated with a material that imparts water resistance through-out.4.4 Fiber-reinforced
17、 gypsum panels, type X (special fire-resistant) designates fiber-reinforced gypsum panels complyingwith this specification that provide not less than 1-h fireresistance rating for panels58-in. 15.9-mm thick or34-h fireresistance rating for panels12-in. 12.7-mm thick, appliedparallel with and on each
18、 side of load bearing 2 by 4 woodstuds spaced 16 in. 406 mm on center with 6d coated nails,178-in. 48-mm long, 0.0915-in. 2.3-mm diameter shank,14-in. 6.4-mm diameter heads, spaced 7 in. 178 mm on centerwith fiber-reinforced gypsum panel joints staggered 16 in. 406mm on each side of the partition an
19、d tested in accordance withTest Methods E119.NOTE 1Consult producers for independent test data on assemblydetails and fire resistance ratings for other types of construction. See firetest reports or listings from recognized fire testing laboratories forassembly particulars, materials, and ratings.4.
20、5 Fiber-reinforced gypsum panels shall have a flamespread index of not more than 25 when tested in accordancewith Test Method E84.4.6 Physical Properties, Dimensions, and Tolerances ofGypsum Panel:4.6.1 Specimens shall be taken from samples obtained inaccordance with Specification C1264.4.6.1.1 Spec
21、imens shall be tested in accordance with TestMethods C473.4.6.2 Core, End, and Edge HardnessThe specimens shallhave an average hardness of not less than 20 lbf 90 N whentested in accordance with Method B.4.6.3 Edges and EndsThe edges and ends shall bestraight.4.6.4 LengthThe nominal length shall be
22、from 6 to 24 ft1830 to 7320 mm, with a tolerance of 614 in. 6 mm fromthe specified length.4.6.5 Tapered Edge DepthThe average thickness of theedge of recessed or tapered edge shall be not less than 0.020 in.0.51 mm but not more than 0.090 in. 2.29 mm less than theaverage thickness of the fiber-reinf
23、orced gypsum panel.5. Interior Fiber-Reinforced Gypsum Panels5.1 Physical Properties of Interior Fiber-Reinforced Gyp-sum Panels:5.1.1 Flexural StrengthThe specimens shall be tested faceup and face down. The average breaking load shall be not lessthan the following:Thickness, in. mm Method B, lbf N1
24、2 12.7 110 49058 15.9 155 6905.1.2 Humidified DeflectionThe specimens shall have anaverage deflection of not more than the following:Thickness, in. mm Deflection, eighths of an inch, mm12 12.7 3 1058 15.9 2 65.1.3 Nail Pull ResistanceThe specimens shall have anaverage nail pull resistance of not les
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1278C1278M2007A2011STANDARDSPECIFICATIONFORFIBERREINFORCEDGYPSUMPANEL 纤维 增强 石膏 镶板 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-464048.html