ASTM C1270-1997(2012) Standard Practice for Detection Sensitivity Mapping of In-Plant Walk-Through Metal Detectors 《内置式过道金属探测器检测灵敏度的映射标准操作规程》.pdf
《ASTM C1270-1997(2012) Standard Practice for Detection Sensitivity Mapping of In-Plant Walk-Through Metal Detectors 《内置式过道金属探测器检测灵敏度的映射标准操作规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1270-1997(2012) Standard Practice for Detection Sensitivity Mapping of In-Plant Walk-Through Metal Detectors 《内置式过道金属探测器检测灵敏度的映射标准操作规程》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1270 97 (Reapproved 2012)Standard Practice forDetection Sensitivity Mapping of In-Plant Walk-ThroughMetal Detectors1This standard is issued under the fixed designation C1270; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revi
2、sion, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONNuclear regulatory authorities require personnel entering designated security areas to be screenedfo
3、r concealed weapons. Additionally, in security areas containing specified quantities of specialnuclear materials, exiting personnel are required to be screened for metallic nuclear shielding material.Walk-through metal detectors are widely used to implement these requirements.A number of environment
4、al conditions, architectural and electrical arrangements near the detector,and detector characteristics affect the detection of metallic objects passing through the walk-throughmetal detector. These external effects and detector characteristics are discussed in Practices F1468 andC1269, and Guide C1
5、238. This practice is intended to minimize the effects of these variables ondetector operation by providing the operator with baseline information on the metal detectionsensitivity within the portal aperture, particularly the location of any weak areas of detection. The datais obtained by mapping th
6、e detection zone (volume within the portal) of each detector at its fieldlocation, under normal operating conditions, and using the target test object. The maps, when appliedto detector operation, ensure that the effects of the fixed environmental conditions, architectural andelectrical arrangements
7、, and detector characteristics are taken into account during operationalsensitivity adjustment, performance evaluation, and general operation of detectors.1. Scope1.1 This standard practice covers a procedure for determin-ing the weakest detection path through the portal aperture andthe worst-case o
8、rthogonal orientation of metallic test objects. Itresults in detection sensitivity maps, which model the detectionzone in terms related to detection sensitivity and identify theweakest detection paths. Detection sensitivity maps supportsensitivity adjustment and performance evaluation procedures(see
9、 Practices C1269 and C1309).NOTE 1Unsymmetrical metal objects possessing a primary longitudi-nal component, such as handguns and knives, usually have one particularorientation that produces the weakest detection signal. The orientation andthe path through the detector aperture where the weakest resp
10、onse isproduced may not be the same for all test objects, even those with verysimilar appearance.NOTE 2In the case of multiple specified test objects or for test objectsthat are orientation sensitive, it may be necessary to map each objectseveral times to determine the worst-case test object or orie
11、ntation, orboth.1.2 This practice is one of several developed to assistoperators of walk-through metal detectors with meeting themetal detection performance requirements of the responsibleregulatory authority. (See Appendix X2)1.3 This practice is neither intended to set performancelevels, nor limit
12、 or constrain operational technologies.1.4 This practice does not address safety or operationalissues associated with the use of walk-through metal detectors.1.5 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.2. Referenced Doc
13、uments2.1 ASTM Standards:2C1238 Guide for Installation of Walk-Through Metal De-tectorsC1269 Practice for Adjusting the Operational SensitivitySetting of In-Plant Walk-Through Metal DetectorsC1309 Practice for Performance Evaluation of In-PlantWalk-Through Metal Detectors1This practice is under the
14、jurisdiction of ASTM Committee C26 on NuclearFuel Cycle and is the direct responsibility of Subcommittee C26.12 on SafeguardApplications.Current edition approved Jan. 1, 2012. Published January 2012. Originallyapproved in 1994. Last previous edition approved in 1997 as C1270 97(2003).DOI: 10.1520/C1
15、270-97R12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Driv
16、e, PO Box C700, West Conshohocken, PA 19428-2959, United States.F1468 Practice for Evaluation of Metallic Weapons Detec-tors for Controlled Access Search and Screening3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 clean-tester, na person who does not carry anyextraneous metal
17、lic objects that would significantly alter thesignal produced when the person carries a test object.3.1.1.1 DiscussionBy example but not limitation, suchextraneous metallic objects may include: metallic belt buckles,metal buttons, cardiac pacemakers, coins, metal frame eyeglasses, hearing aids, jewe
18、lry, keys, mechanical pens andpencils, shoes with metal shanks or arch supports, metallicsurgical implants, undergarment support metal, metal zippers,etc. In the absence of other criteria, a clean tester passingthrough a metal detector shall not cause a disturbance signalgreater than 10 % of that pr
19、oduced when carrying the criticaltest object through the detector. Test objects requiring veryhigh sensitivity settings for detection require more completeelimination of extraneous metal to obtain less than 10 % signaldisturbance.3.1.1.2 DiscussionThe tester shall have a weight between50 to 104 kg (
20、110 to 230 lb) and a height between 1.44 to 1.93m (57 to 75 in.). Should a given detector be sensitive to bodysize because of design or desired sensitivity, the physical sizeof testers should be smaller and within a narrower range.3.1.1.3 DiscussionIt is recommended that the clean testerbe surveyed
21、with a high sensitivity hand-held metal detector toensure that no metal is present.3.1.2 critical orientation, nthe orthogonal orientation of atest object that produces the smallest detection signal orweakest detection anywhere in the detection zone; the orthogo-nal orientation of a test object that
22、 requires a higher sensitivitysetting to be detected compared to the sensitivity settingrequired to detect the object in all other orthogonal orienta-tions. See Fig. 1 for handgun orientations.3.1.2.1 DiscussionCritical orientations are determined bytesting using a mapping procedure such as describe
23、d inPractice C1270.3.1.2.2 DiscussionThe term critical orientation can referto the worst case orthogonal orientation in a single test path orthe worst case orthogonal orientation for all the test paths (theentire detection zone). The two are coincident in the critical testpath.3.1.3 critical sensiti
24、vity setting, nthe lowest sensitivitysetting of a detector at which the critical test object in itscritical orientation is consistently detected (10 out of 10 testpasses) when passed through the detection zone on the criticaltest path.3.1.4 critical test element, nsee test element.3.1.5 critical tes
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC127019972012STANDARDPRACTICEFORDETECTIONSENSITIVITYMAPPINGOFINPLANTWALKTHROUGHMETALDETECTORS 内置

链接地址:http://www.mydoc123.com/p-464011.html