1、Designation: C1257 06a (Reapproved 2012)Standard Test Method forAccelerated Weathering of Solvent-Release-Type Sealants1This standard is issued under the fixed designation C1257; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method includes two laboratory acceleratedexposure procedures for predicting the effects of ultravio
3、let orultraviolet/visible radiation, heat, and moisture on color,chalking, cracking, and adhesion of solvent-release sealants.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address all
4、 of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1.4 The committee with jurisdiction over this standard is notawa
5、re of any comparable standards published by other orga-nizations.2. Referenced Documents2.1 ASTM Standards:2C717 Terminology of Building Seals and SealantsC1442 Practice for Conducting Tests on Sealants UsingArtificial Weathering ApparatusG113 Terminology Relating to Natural and Artificial Weath-eri
6、ng Tests of Nonmetallic MaterialsG151 Practice for Exposing Nonmetallic Materials in Accel-erated Test Devices that Use Laboratory Light SourcesG154 Practice for Operating Fluorescent LightApparatus forUV Exposure of Nonmetallic MaterialsG155 Practice for Operating Xenon Arc Light Apparatus forExpos
7、ure of Non-Metallic Materials3. Terminology3.1 Definitions:3.1.1 Refer to Terminology C717 and G113 for definitionsof terms used in this test method.4. Summary of Test Method4.1 Four test specimens are prepared in U-shaped aluminumchannels. After curing, three of the specimens are exposed inthe labo
8、ratory accelerated weathering device and the fourthspecimen is stored under standard conditions as an unexposedfile specimen.At the end of the exposure period, the specimensare examined for chalking, color change, center cracking, edgecracking, and loss of adhesion versus the unexposed filespecimen.
9、5. Significance and Use5.1 It is difficult to establish a precise correlation betweenlaboratory accelerated and natural weathering because of (1)geographical climatic variations, local weather variation fromnormal, and local pollutants and (2) the fact that the accelera-tion factor is material depen
10、dent, varying with the type ofmaterial as well as its formulation. This test method is used todetermine the resistance of a sealant to laboratory acceleratedweathering and, if a control material with known outdoorweathering performance is used, the relative weathering per-formance of the sealant aga
11、inst that of the control material.5.2 This test method is conducted using aluminum channels.Other substrate materials may show different results.6. Apparatus6.1 Exposure Apparatus:6.1.1 Fluorescent UV/Condensation Apparatus, that con-forms to the requirements in Practices G151 and G154 withUVA-340 t
12、ype lamps.6.1.2 Xenon-Arc Apparatus, that conforms to the require-ments in Practices G151 and G155 with daylight type filters.6.2 Four-Mill Finish Aluminum U-Channels, 76 mm longby 19 mm wide by 9.5 mm deep (3 by34 by38 in.) insidedimensions. Additional substrate materials may be specified.6.3 Steel
13、 Spatula.7. Procedure7.1 Condition sufficient compound in an original closedcontainer for at least 24 h at standard conditions. Standard1This test method is under the jurisdiction ofASTM Committee C24 on BuildingSeals and Sealantsand is the direct responsibility of Subcommittee C24.40 onWeathering.C
14、urrent edition approved Dec. 1, 2012. Published December 2012. Originallyapproved in 1994. Last previous edition approved in 2006 as C1257-06a. DOI:10.1520/C1257-06AR12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annua
15、l Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1conditions are to be a temperature of 23 6 2C (73 6 3.6F)and relative humidity
16、 of 50 6 5%.7.2 Prepare four sealant test specimens in aluminumU-channels.7.2.1 Thoroughly clean channels using a suitable solventsuch as methyl ethyl ketone (MEK). Allow to dry before fillingwith sealant.7.2.2 Block the ends of the U-channels with masking tapeand overfill the entire channel with co
17、nditioned compoundfrom the bottom up being careful to avoid air entrapment.Strike the channel off flat with a spatula. Do not remove themasking tape. It is to stay in place for the entire test. Removingit may disturb the uncured or cured sealant.7.3 Cure the test specimens at standard conditions for
18、 21days.NOTE 1The producer may request conditions other than thosespecified in 7.3 for the curing period, provided they meet the followingrequirements: the curing period must extend for 21 days, and thetemperature during the curing period shall not exceed 70C (158F).7.4 After the curing period, plac
19、e three of the specimens inone of the laboratory accelerated exposure devices listedbelow. Choice of the type of apparatus shall be by mutualagreement among the interested parties. Because of differencesin type of light source and test conditions, test results maydiffer with the type of apparatus us
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC12572006A2012STANDARDTESTMETHODFORACCELERATEDWEATHERINGOFSOLVENTRELEASETYPESEALANTS 溶剂 释放 密封剂 加速

链接地址:http://www.mydoc123.com/p-463950.html