ASTM C1204-2014 Standard Test Method for Uranium in Presence of Plutonium by Iron&40 II&41 Reduction in Phosphoric Acid Followed by Chromium&40 VI&41 Titration《在有钚存在的情况下经铬(VI)滴定后用磷.pdf
《ASTM C1204-2014 Standard Test Method for Uranium in Presence of Plutonium by Iron&40 II&41 Reduction in Phosphoric Acid Followed by Chromium&40 VI&41 Titration《在有钚存在的情况下经铬(VI)滴定后用磷.pdf》由会员分享,可在线阅读,更多相关《ASTM C1204-2014 Standard Test Method for Uranium in Presence of Plutonium by Iron&40 II&41 Reduction in Phosphoric Acid Followed by Chromium&40 VI&41 Titration《在有钚存在的情况下经铬(VI)滴定后用磷.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1204 14Standard Test Method forUranium in Presence of Plutonium by Iron(II) Reduction inPhosphoric Acid Followed by Chromium(VI) Titration1This standard is issued under the fixed designation C1204; the number immediately following the designation indicates the year oforiginal adoption
2、or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers unirradiated uranium-plutoniummixed oxide having a ur
3、anium to plutonium ratio of 2.5 andgreater. The presence of larger amounts of plutonium (Pu) thatgive lower uranium to plutonium ratios may give low analysisresults for uranium (U) (1)2, if the amount of plutoniumtogether with the uranium is sufficient to slow the reductionstep and prevent complete
4、reduction of the uranium in theallotted time. Use of this test method for lower uranium toplutonium ratios may be possible, especially when 20 to 50 mgquantities of uranium are being titrated rather than the 100 to300 mg in the study cited in Ref (1). Confirmation of thatinformation should be obtain
5、ed before this test method is usedfor ratios of uranium to plutonium less than 2.5.1.2 The amount of uranium determined in the data presentedin Section 12 was 20 to 50 mg. However, this test method, asstated, contains iron in excess of that needed to reduce thecombined quantities of uranium and plut
6、onium in a solutioncontaining 300 mg of uranium with uranium to plutoniumratios greater than or equal to 2.5. Solutions containing up to300 mg uranium with uranium to plutonium ratios greater thanor equal to 2.5 have been analyzed (1) using the reagentvolumes and conditions as described in Section 1
7、0.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish ap
8、pro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatements, see Section 8.2. Referenced Documents2.1 ASTM Standards:3C852 Guide for Design Criteria for Plutonium GloveboxesC1128 Guide for Preparation of Working Refere
9、nce Materi-als for Use in Analysis of Nuclear Fuel Cycle MaterialsC1168 Practice for Preparation and Dissolution of PlutoniumMaterials for Analysis3. Summary of Test Method3.1 Samples are prepared by dissolution techniques detailedin Practice C1168 and Ref (2). Aliquants containing 20 to 300mg of ur
10、anium, as selected by the facility procedure, areprepared by weight. The sample is fumed to incipient drynessafter the addition of sulfuric acid. The sample is dissolved indilute sulfuric acid prior to titration.3.2 Uranium is reduced to uranium(IV) by excess ferrous(iron(II) in concentrated phospho
11、ric acid (H3PO4) containingsulfamic acid. The excess iron(II) is selectively oxidized bynitric acid (HNO3) in the presence of molybdenum(VI) cata-lyst. After the addition of vanadium(IV), the uranium(IV) istitrated with chromium(VI) to a potentiometric end point (3, 4).3.3 A single chromium(VI) titr
12、ant delivered manually on aweight or volume basis is used. The concentration of thechromium(VI) solution is dependent upon the amount ofuranium being titrated (see 7.8). Automated titrators that havecomparable precisions can be used.NOTE 1An alternative ceric (V) sulfate or nitrate titrant may also
13、beused, providing that the user demonstrates equivalent performance to thedichromate titrant.3.4 For the titration of uranium alone, the precision of themodified Davies and Gray titration method has been signifi-cantly improved by increasing the amount of uranium titratedto 1 g and delivering about
14、90 % of the titrant on a solid massbasis followed by titration to the end point with a dilute titrant(5). This modification has not been studied for the titration ofuranium in the presence of plutonium, and confirmation of itsapplicability should be obtained by the facility prior to its use.1This te
15、st method is under the jurisdiction ofASTM Committee C26 on NuclearFuel Cycle and is the direct responsibility of Subcommittee C26.05 on Methods ofTest.Current edition approved June 1, 2014. Published July 2014. Originally approvedin 1991. Last previous edition approved in 2008 as C1204 02 (2008)1.
16、DOI:10.1520/C1204-14.2The boldface numbers in parentheses refer to the list of references at the end ofthis test method.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer
17、 to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.5 The modification of the Davies and Gray titrationmethod, as described originally in Ref (4), may be used insteadof the meth
18、od described herein, where laboratories havedemonstrated no plutonium interference at the uranium toplutonium ratios and amounts titrated at that facility. If anymodification is made to the procedure in Ref (4) for applicationat the facility to uranium, plutonium mixed oxides, confirma-tion that the
19、 modification does not degrade the analysistechnique as stated should be demonstrated prior to its use.4. Significance and Use4.1 Factors governing selection of a method for the deter-mination of uranium include available quantity of sample,sample purity, desired level of reliability, and equipmenta
20、vailability.4.2 This test method is suitable for samples between 20 to300 mg of uranium, is applicable to fast breeder reactor(FBR)-mixed oxides having a uranium to plutonium ratio of2.5 and greater, is tolerant towards most metallic impurityelements usually specified for FBR-mixed oxide fuel, and u
21、sesno special equipment.4.3 The ruggedness of the titration method has been studiedfor both the volumetric (6) and the weight (7) titration ofuranium with dichromate.5. Interferences5.1 Interfering elements are not generally present in signifi-cant quantities in mixed uranium, plutonium oxide produc
22、tmaterial. However, elements that cause bias when present inmilligram quantities are silver (Ag), vanadium (V), plutonium(Pt), ruthenium (Ru), osmium (Os), and iodine (I). Interferencefrom tin (Sn), arsenic (As), antimony (Sb), molybdenum (Mo),manganese (Mn), fluorine (F), chlorine (Cl), and bromine
23、 (Br)are eliminated when the preparation procedure is followed asgiven (4, 8, 9, 10, 11, 12) in this titrimetric method. Of themetallic impurity elements usually included in specificationsfor FBR-mixed oxide fuel, silver, manganese, lead (Pb), andvanadium interfere.5.2 Other interfering metallic ele
24、ments are gold (Au), mer-cury (Hg), iridium (Ir), and palladium (Pd). Elimination oftheir interference requires their separation from uranium bysuch techniques as ion exchange and solvent extraction (13,14).5.3 An initial fuming with sulfuric acid removes suchimpurity elements as the halides and vol
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC12042014STANDARDTESTMETHODFORURANIUMINPRESENCEOFPLUTONIUMBYIRON40II41REDUCTIONINPHOSPHORICACIDFOLLOWEDBYCHROMIUM40VI41TITRATION

链接地址:http://www.mydoc123.com/p-463751.html