ASTM C120 C120M-2009 Standard Test Methods of Flexure Testing of Slate (Breaking Load Modulus of Rupture Modulus of Elasticity)《石板的弯曲标准试验方法(断裂荷载、弯曲模数和弹性模数)》.pdf
《ASTM C120 C120M-2009 Standard Test Methods of Flexure Testing of Slate (Breaking Load Modulus of Rupture Modulus of Elasticity)《石板的弯曲标准试验方法(断裂荷载、弯曲模数和弹性模数)》.pdf》由会员分享,可在线阅读,更多相关《ASTM C120 C120M-2009 Standard Test Methods of Flexure Testing of Slate (Breaking Load Modulus of Rupture Modulus of Elasticity)《石板的弯曲标准试验方法(断裂荷载、弯曲模数和弹性模数)》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 120/C 120M 09Standard Test Methods ofFlexure Testing of Slate (Breaking Load, Modulus ofRupture, Modulus of Elasticity)1This standard is issued under the fixed designation C 120/C 120M; the number immediately following the designation indicates the yearof original adoption or, in the
2、case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.INTRODUCTIONDue to
3、the unique properties of slate, the flexure test is better adapted to use for strength andelasticity determinations than either compression or tension tests. Furthermore, several uses of slatesare such that these determinations are of special interest and value, besides furnishing comparativedata.Th
4、e property of slate termed “grain” causes a slab of the material to break transversely in onedirection somewhat more readily than at right angles to this direction. For this reason it is desirableto test the strength and elasticity both parallel and perpendicular to the grain.Breaking load test resu
5、lts for samples of roofing slate are only valid for the commercial supply ofslates of that thickness or greater. For the commercial supply of thinner roofings slates, testing onsamples of the minimum specified thickness must be conducted.When comparing slates of equal thickness, but from various sou
6、rces, slates which meet the requiredbreaking load at the lowest specimen thickness will yield the best performance on the roof in termsof resistance to impact damage.1. Scope1.1 These test methods cover determination of the breakingload, modulus of rupture and modulus of elasticity of slate bymeans
7、of flexure tests.1.2 UnitsThe values stated in either SI units or inch-pound units are to be regarded separately as standard. Thevalues stated in each system may not be exact equivalents;therefore, each system shall be used independently of the other.Combining values from the two systems may result
8、in non-conformance with the standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory lim
9、itations prior to use.2. Referenced Documents2.1 ASTM Standards:2C99 Test Method for Modulus of Rupture of DimensionStoneC119 Terminology Relating to Dimension Stone3. Terminology3.1 DefinitionsAll definitions are in accordance with Ter-minology C119.4. Significance and Use4.1 These test methods are
10、 useful in indicating the differ-ences in flexure (breaking load, modulus of rupture, modulusof elasticity) between various slates. These test methods alsoprovide one element in the comparison of slates.1These test methods are under the jurisdiction of ASTM Committee C18 onDimension Stone and are th
11、e direct responsibility of Subcommittee C18.01 on TestMethods.Current edition approved April 1, 2009. Published April 2009. Originallyapproved in 1925. Last previous edition approved in 2006 as C 120061.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Ser
12、vice at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5. Sampling5.1 Select the sample to represe
13、nt a true average of the typeor grade of stone under consideration and of the qualitysupplied to the market under the type designation to be tested.The sample may be selected by the purchaser or his authorizedrepresentative from the quarried stone or taken from the naturalledge and shall be of adequ
14、ate size to permit the preparation ofthe desired number of test specimens. When perceptiblevariations occur, the purchaser may select as many samples asare necessary for determining the variations in flexure (break-ing load, modulus of rupture, modulus of elasticity).MODULUS OF RUPTURE6. Test Specim
15、ens6.1 Structural or Electrical SlateSix representative speci-mens, 12 by 112 by 1 in. 300 by 40 by 25 mm in size, of theparticular slate under consideration shall be tested.6.2 Roofing SlateAt least ten specimens 4 in. 101.6 mmin width, 5 in. 125 mm or greater in length and minimum316in. 5 mm thick
16、.7. Preparation of Specimens7.1 Structural or Electrical SlateSplit the slate for the testto a thickness of approximately 114 in. 30 mm and then sawinto strips 12 in. 300 mm in length by 112 in. 40 mm inwidth. Cut half of these with the length parallel to the grain andhalf with the length perpendicu
17、lar to the grain. Plane or rubdown the 12 by 112-in. 300 by 40-mm faces to a thickness ofapproximately 1 in. 25 mm, taking care to have the finishedsurfaces as nearly parallel as practicable.7.2 Roofing SlateCut one 4 by 5-in. 100 by 125-mmspecimen from each of a minimum 10 shingles. The saw bladesh
18、all be a continuous rim, diamond impregnated type, mountedto a water-cooled sliding bed saw capable of making a cleancut with no lacerated edges. Cut no part of the specimen nearerthan 1 in. 25 mm to a sheared edge or nail hole. The 5 in.125 mm or longer dimension is to be measured and cutparallel w
19、ith the long dimension of the slate shingle. Do notresurface the split faces.8. Conditioning8.1 Dry the specimens for 48 h in a ventilated oven at atemperature of 140 6 4F 60 6 2C. At the 46th, 47th and48th hour, weigh the specimens to ensure that the weight is thesame. If the weight continues to dr
20、op, continue to dry thespecimens until there are three successive hourly readings withthe same weight.9. Marking and Measuring9.1 On structural or electrical slate, rule the center lines witha try-square perpendicular to the edges of the specimens.Likewise, rule the span lines, parallel to, and 5 in
21、. 125 mmfrom, the center lines. On specimens of roofing slate rule thecenter lines perpendicular to an edge that is parallel to thelength of the shingle. Rule span lines parallel to, and 1 in.25 mm from, the center lines. Measure the specimen thick-ness at three points along the center line to the n
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC120C120M2009STANDARDTESTMETHODSOFFLEXURETESTINGOFSLATEBREAKINGLOADMODULUSOFRUPTUREMODULUSOFELASTICITY

链接地址:http://www.mydoc123.com/p-463731.html