ASTM C1157-2003 Standard Performance Specification for Hydraulic Cement《水凝水泥的标准性能规范》.pdf
《ASTM C1157-2003 Standard Performance Specification for Hydraulic Cement《水凝水泥的标准性能规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1157-2003 Standard Performance Specification for Hydraulic Cement《水凝水泥的标准性能规范》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1157 03Standard Performance Specification forHydraulic Cement1This standard is issued under the fixed designation C 1157; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parenth
2、eses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers hydraulic cements for bothgeneral and special applications. This is a specification givingperformance requirements. There are
3、 no restrictions on thecomposition of the cement or its constituents.1.2 The specification classifies cements by type based onspecific requirements for general use, high early strength,resistance to attack by sulfates, and heat of hydration. Optionalrequirements are provided for the property of low
4、reactivitywith alkali-reactive aggregates.1.3 For properties where values are given in both SI andinch-pound units, the values in SI units are to be regarded asthe standard. Values in SI units shall be obtained by measure-ment in SI units or by appropriate conversion, using the Rulesfor Conversion a
5、nd Rounding given in IEEE/ASTM SI 10, ofmeasurements made in other units.1.4 The text of this standard refers to notes and footnotesthat provide explanatory material. These notes and footnotes(excluding those in tables and figures) are not requirements ofthe standard.1.5 This standard does not purpo
6、rt to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1Specification C 150 is a prescription spe
7、cification for portlandcement and Specifications C 595 is a specification for blended hydrauliccement where the products that may be furnished are of restricted natureand proportions and where the products must meet prescriptive require-ments as to chemical and physical properties.2. Referenced Docu
8、ments2.1 ASTM Standards:2C 109/C 109M Test Method for Compressive Strength ofHydraulic Cement Mortars (Using 2-in. or 50-mm CubeSpecimens)C 114 Test Methods for Chemical Analysis of HydraulicCementC 150 Specification for Portland CementC 151 Test Method for Autoclave Expansion of PortlandCementC 183
9、 Practice for Sampling and the Amount of Testing ofHydraulic CementC 185 Test Method for Air Content of Hydraulic CementMortarC 186 Test Method for Heat of Hydration of HydraulicCementC 188 Test Method for Density of Hydraulic CementC 191 Test Method for Time of Setting of Hydraulic Ce-ment by Vicat
10、 NeedleC 204 Test Method for Fineness of Hydraulic Cement byAir Permeability ApparatusC 219 Terminology Relating to Hydraulic CementC 226 Specification for Air-Entraining Additions for Use inthe Manufacture of Air-Entraining Hydraulic CementC 227 Test Method for Potential Alkali Reactivity ofCement-
11、Aggregate Combinations (Mortar-Bar Method)C 311 Test Methods for Sampling and Testing Fly Ash orNatural Pozzolans for Use as a Mineral Admixture inPortland-Cement ConcreteC 430 Test Method for Fineness of Hydraulic Cement bythe 45-m (No. 325) SieveC 441 Test Method for Effectiveness of Pozzolans orG
12、round Blast-Furnace Slag in Preventing Excessive Ex-pansion of Concrete Due to the Alkali-Silica ReactionC 451 Test Method for Early Stiffening of Hydraulic Ce-ment (Paste Method)C 465 Specification for Processing Additions for Use in theManufacture of Hydraulic CementsC 595 Specifications for Blend
13、ed Hydraulic CementsC 688 Specification for Functional Additions for Use inHydraulic CementsC 1012 Test Method for Length Change of Hydraulic-Cement Mortars Exposed to a Sulfate SolutionC 1038 Test Method for Expansion of Portland CementMortar Bars Stored in Water1This specification is under the jur
14、isdiction of ASTM Committee C01 onCement and is the direct responsibility of Subcommittee C01.10 on HydraulicCements for General Concrete Construction.Current edition approved Nov. 1, 2003. Published December 2003. Originallyapproved in 1992. Last previous edition approved in 2002 as C 1157 02.2For
15、referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700,
16、 West Conshohocken, PA 19428-2959, United States.IEEE/ASTM SI 10 Standard for Use of the InternationalSystem of Units (SI): the Modern Metric System3. Terminology3.1 Definitions:3.1.1 Terms used in this specification are defined in Termi-nology C 219, except for the following terms.3.1.2 blended hyd
17、raulic cementa hydraulic cement con-sisting of two or more inorganic ingredients which contributeto the strength-gaining properties of the cement, with orwithout other ingredients, processing additions, and functionaladditions.3.1.2.1 Blended hydraulic cements are made by intergrind-ing or other ble
18、nding processes.4. Nomenclature4.1 As selected by the producer, designate cements underthis specification in accordance with the following names. Thenomenclature does not establish or require any limits on thecomposition or properties of a cement. Its only purpose is toprovide a uniform means for de
19、signating the cement after itsingredients and proportions have been selected by the manu-facturer, thereby providing general information about thecement when the manufacturer so chooses.4.2 Hydraulic CementAny cement meeting the require-ments of this specification is a hydraulic cement. At the optio
20、nof the producer, use this designation in addition to, or in lieu of,any other proper designation.4.3 Portland Cement, consisting of portland-cement clinkerto which, at the option of the manufacturer, one or more of thefollowing additions, and no others, shall have been madeduring manufacture.4.3.1
21、Calcium sulfate set-control addition.4.3.2 Water, including that present in clinker and otheradditions, in amounts such that loss-on-ignition does notexceed 3.0 % by mass of the cement.4.3.3 Processing additions up to the maximum amountdemonstrating conformance to the applicable specification.4.3.4
22、Air-Entraining Portland Cement shall contain an in-terground air-entraining addition.4.4 Blended Hydraulic Cements:4.4.1 Modified Portland Cements contain up to 15 % of amineral ingredient besides portland-cement clinker, and, asselected by the producer, are designated “ingredient-modifiedportland c
23、ement” in accordance with the identity of the mineralingredient used.4.4.2 Other Blended Hydraulic Cements contain more than15 % of two or more mineral ingredients and, as selected by theproducer, are named in accordance with the two or, if moreappropriate, three constituents present in greatest amo
24、unt,listed in decreasing order of abundance by mass.5. Additions5.1 Processing AdditionsIf processing additions are usedin the manufacture of cement, they shall conform to therequirements of Specification C 465.5.2 Functional AdditionsIf functional additions of thetypes defined in Specification C 22
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC11572003STANDARDPERFORMANCESPECIFICATIONFORHYDRAULICCEMENT 水泥 标准 性能 规范 PDF

链接地址:http://www.mydoc123.com/p-463565.html