1、Designation: C1157/C1157M 11C1157/C1157M 17Standard Performance Specification forHydraulic Cement1This standard is issued under the fixed designation C1157/C1157M; the number immediately following the designation indicates the yearof original adoption or, in the case of revision, the year of last re
2、vision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This performance specification covers hydraulic cements for both general and special applications. There are no restrictions
3、on the composition of the cement or its constituents (See Note 1).NOTE 1There are two related hydraulic cement standards, Specification C150 for portland cement and Specifications C595 for blended cements, bothof which contain prescriptive and performance requirements1.2 This performance specificati
4、on classifies cements based on specific requirements for general use, high early strength,resistance to attack by sulfates, and heat of hydration. Optional requirements are provided for the property of low reactivity withalkali-silica-reactive aggregates and for air-entraining cements.1.3 The values
5、 stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in eachsystem may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from thetwo systems may result in non-conformance with the standar
6、d. Values in SI units or inch-pound units shall be obtained bymeasurement in SI units or inch-pound units or by appropriate conversion, using the Rules for Conversion and Rounding givenin IEEE/ASTM SI 10, of measurements made in other units or SI units. Values are stated in only SI units when inch-p
7、ound unitsare not used in practice.1.4 The text of this standard refers to notes and footnotes that provide explanatory material. These notes and footnotes(excluding those in tables and figures) are not requirements of the standard.1.5 This standard does not purport to address all of the safety conc
8、erns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.1.6 This international standard was developed in accordance with internationally reco
9、gnized principles on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2C109/C109M Test Method
10、 for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or 50-mm Cube Specimens)C114 Test Methods for Chemical Analysis of Hydraulic CementC150 Specification for Portland CementC151 Test Method for Autoclave Expansion of Hydraulic CementC183 Practice for Sampling and the Amount of Testing
11、 of Hydraulic CementC185 Test Method for Air Content of Hydraulic Cement MortarC186 Test Method for Heat of Hydration of Hydraulic CementC188 Test Method for Density of Hydraulic CementC191 Test Methods for Time of Setting of Hydraulic Cement by Vicat NeedleC204 Test Methods for Fineness of Hydrauli
12、c Cement by Air-Permeability ApparatusC219 Terminology Relating to Hydraulic CementC227 Test Method for Potential Alkali Reactivity of Cement-Aggregate Combinations (Mortar-Bar Method)1 This performance specification is under the jurisdiction of ASTM Committee C01 on Cement and is the direct respons
13、ibility of Subcommittee C01.10 on HydraulicCements for General Concrete Construction.Current edition approved Oct. 1, 2011June 15, 2017. Published October 2011August 2017. Originally approved in 1992. Last previous edition approved in 20102011 asC1157C1157 11.10. DOI: 10.1520/C1157_C1157M-11.10.1520
14、/C1157_C1157M-17.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is
15、 intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the
16、current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1C359 Test Method for Early
17、Stiffening of Hydraulic Cement (Mortar Method)C430 Test Method for Fineness of Hydraulic Cement by the 45-m (No. 325) SieveC441 Test Method for Effectiveness of Pozzolans or Ground Blast-Furnace Slag in Preventing Excessive Expansion of ConcreteDue to the Alkali-Silica ReactionC451 Test Method for E
18、arly Stiffening of Hydraulic Cement (Paste Method)C595 Specification for Blended Hydraulic CementsC596 Test Method for Drying Shrinkage of Mortar Containing Hydraulic CementC1012 Test Method for Length Change of Hydraulic-Cement Mortars Exposed to a Sulfate SolutionC1038 Test Method for Expansion of
19、 Hydraulic Cement Mortar Bars Stored in WaterIEEE/ASTM SI 10 Standard for Use of the International System of Units (SI): the Modern Metric System3. Terminology3.1 Definitions:3.1.1 Terms used in this specification are defined in Terminology C219.4. Classification and Use4.1 The types of hydraulic ce
20、ment covered by this specification are given in 4.2.1 4.2.6 and are classified in accordance withspecific properties defined in Table 1 (See Note 2).NOTE 2This specification is based on hydraulic cement attributes related to concrete performance, including strength development, sulfate resistance,he
21、at of hydration, and resistance to alkali-silica reactivity. Concrete performance is dependent on many factors such as characteristics of other concretematerials, mix design, production, handling, and environmental conditions. For performance properties of concrete, including permeability, resistanc
22、e tofreeze-thaw cycles and deicer salt scaling, additional information may be obtained through the use of comparative testing of concretes.4.2 Cements conforming to this specification shall be designated in accordance with the nomenclature with specialcharacteristics indicated by type in accordance
23、with the types in 4.2.1 4.2.6. When the type is not specified, the requirements oftype GU shall apply.4.2.1 Type GUHydraulic cement for general construction. Use when one or more of the special types are not required.4.2.2 Type HEHigh Early-Strength.4.2.3 Type MSModerate Sulfate Resistance.4.2.4 Typ
24、e HSHigh Sulfate Resistance.4.2.5 Type MHModerate Heat of Hydration.4.2.6 Type LHLow Heat of Hydration.4.3 Additional OptionsThe following additional purchase options apply for any of the principal types listed. When one or bothof these options is invoked, its letter designation and title shall foll
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1157C1157M2017STANDARDPERFORMANCESPECIFICATIONFORHYDRAULICCEMENT 硬性 水泥 标准 性能 规格 PDF

链接地址:http://www.mydoc123.com/p-463564.html