1、Designation: C1157/C1157M 11Standard Performance Specification forHydraulic Cement1This standard is issued under the fixed designation C1157/C1157M; the number immediately following the designation indicates the yearof original adoption or, in the case of revision, the year of last revision. A numbe
2、r in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This performance specification covers hydraulic ce-ments for both general and special applications. There are norestrictions on the composi
3、tion of the cement or its constituents(See Note 1).NOTE 1There are two related hydraulic cement standards, Specifica-tion C150 for portland cement and Specifications C595 for blendedcements, both of which contain prescriptive and performance require-ments1.2 This performance specification classifies
4、 cements basedon specific requirements for general use, high early strength,resistance to attack by sulfates, and heat of hydration. Optionalrequirements are provided for the property of low reactivitywith alkali-silica-reactive aggregates and for air-entrainingcements.1.3 The values stated in eithe
5、r SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard. Values in SI uni
6、ts or inch-pound units shallbe obtained by measurement in SI units or inch-pound unitsor by appropriate conversion, using the Rules for Conversionand Rounding given in IEEE/ASTM SI 10, of measurementsmade in other units or SI units. Values are stated in only SIunits when inch-pound units are not use
7、d in practice.1.4 The text of this standard refers to notes and footnotesthat provide explanatory material. These notes and footnotes(excluding those in tables and figures) are not requirements ofthe standard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated
8、 with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C109/C109M Test Method for Compressive Strength ofHydraulic Cem
9、ent Mortars (Using 2-in. or 50-mm CubeSpecimens)C114 Test Methods for Chemical Analysis of HydraulicCementC150 Specification for Portland CementC151 Test Method for Autoclave Expansion of HydraulicCementC183 Practice for Sampling and the Amount of Testing ofHydraulic CementC185 Test Method for Air C
10、ontent of Hydraulic CementMortarC186 Test Method for Heat of Hydration of HydraulicCementC188 Test Method for Density of Hydraulic CementC191 Test Methods for Time of Setting of HydraulicCement by Vicat NeedleC204 Test Methods for Fineness of Hydraulic Cement byAir-Permeability ApparatusC219 Termino
11、logy Relating to Hydraulic CementC227 Test Method for Potential Alkali Reactivity ofCement-Aggregate Combinations (Mortar-Bar Method)C359 Test Method for Early Stiffening of Hydraulic Cement(Mortar Method)C430 Test Method for Fineness of Hydraulic Cement by the45-m (No. 325) SieveC441 Test Method fo
12、r Effectiveness of Pozzolans orGround Blast-Furnace Slag in Preventing Excessive Ex-pansion of Concrete Due to the Alkali-Silica ReactionC451 Test Method for Early Stiffening of Hydraulic Cement(Paste Method)C595 Specification for Blended Hydraulic CementsC596 Test Method for Drying Shrinkage of Mor
13、tar Contain-ing Hydraulic CementC1012 Test Method for Length Change of Hydraulic-Cement Mortars Exposed to a Sulfate Solution1This performance specification is under the jurisdiction of ASTM CommitteeC01 on Cement and is the direct responsibility of Subcommittee C01.10 onHydraulic Cements for Genera
14、l Concrete Construction.Current edition approved Oct. 1, 2011. Published October 2011. Originallyapproved in 1992. Last previous edition approved in 2010 as C115710. DOI:10.1520/C1157_C1157M-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at s
15、erviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,
16、United States.C1038 Test Method for Expansion of Hydraulic CementMortar Bars Stored in WaterIEEE/ASTM SI 10 Standard for Use of the InternationalSystem of Units (SI): the Modern Metric System3. Terminology3.1 Definitions:3.1.1 Terms used in this specification are defined in Termi-nology C219.4. Clas
17、sification and Use4.1 The types of hydraulic cement covered by this specifi-cation are given in 4.2.1-4.2.6 and are classified in accordancewith specific properties defined in Table 1 (See Note 2).NOTE 2This specification is based on hydraulic cement attributesrelated to concrete performance, includ
18、ing strength development, sulfateresistance, heat of hydration, and resistance to alkali-silica reactivity.Concrete performance is dependent on many factors such as characteris-tics of other concrete materials, mix design, production, handling, andenvironmental conditions. For performance properties
19、 of concrete, includ-ing permeability, resistance to freeze-thaw cycles and deicer salt scaling,additional information may be obtained through the use of comparativetesting of concretes.4.2 Cements conforming to this specification shall be des-ignated in accordance with the nomenclature with special
20、characteristics indicated by type in accordance with the typesin 4.2.1-4.2.6. When the type is not specified, the requirementsof type GU shall apply.4.2.1 Type GUHydraulic cement for general construction.Use when one or more of the special types are not required.4.2.2 Type HEHigh Early-Strength.TABL
21、E 1 Standard Physical RequirementsCement TypeApplicableTest MethodGU HE MS HS MH LHFineness C204,C430AAAAAAAutoclave length change, max, % C151 0.80 0.80 0.80 0.80 0.80 0.80Time of setting, vicat testBC191Initial, not less than, minutes 45 45 45 45 45 45Initial, not more than, minutes 420 420 420 42
22、0 420 420Air content of mortar volume, max, %CC185 12 12 12 12 12 12Compressive strengthminimum, MPa psiDC109/C109M1 day . 12.0 1740 . . . .3 days 13.0 1890 24.0 3480 11.0 1600 11.0 1600 5.0 725 .7 days 20.0 2900 . 18.0 2610 18.0 2610 11.0 1600 11.0 160028 days 28.0 4060 . . 25.0 3620 . 21.0 3050Hea
23、t of hydration C1867 days, max, kJ/kg kcal/kg28 days, max, kJ/kg kcal/kg.290 70.250 60290 70Mortar bar expansion C103814 days, % max 0.020 0.020 0.020 0.020 0.020 0.020Sulfate expansion(sulfate resistance)EC10126 months, max, %1 year, max, %.0.10.0.050.10.Optional Physical RequirementsOption AAir en
24、trainingC,FC185Air content ofmortar, vol %max 22 22 22 22 22 22min 16 16 16 16 16 16Option RLow reactivity withalkali-silica-reactive aggregatesGC227Expansion at14 days, max, %56 days, max, %0.0200.0600.0200.0600.0200.0600.0200.0600.0200.0600.0200.060Early stiffening, finalpenetration, min,%C451 50
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1157C1157M2011STANDARDPERFORMANCESPECIFICATIONFORHYDRAULICCEMENT 水泥 标准 性能 规范 PDF

链接地址:http://www.mydoc123.com/p-463563.html