1、Designation: C 1126 04Standard Specification forFaced or Unfaced Rigid Cellular Phenolic ThermalInsulation1This standard is issued under the fixed designation C 1126; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、 revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers faced or unfaced, rigid cellularphenolic thermal insulation. Boards shall be faced or unfaced.T
3、ubular forms covered by this standard shall be unfaced. Itdoes not apply to field expanded cellular phenolic materials.NOTE 1If a facer or vapor retarder is to be used for the tubular form,then refer to Practice C 9211.2 Materials covered by this specification are used as roofinsulation; sheathing o
4、r rigid board for non-load bearing,building material applications; and pipe insulation for usebetween 40 and 257F (40 and 125C). Type II Grade 1 andType III Grade 1 materials with an appropriate vapor retardercovering on the warm surface can be used to a lowertemperature limit of 290F (180C). (See 7
5、.2.)1.3 The values stated in inch-pound units are to be regardedas standard. International Standard Units (SI) are given inparentheses.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to est
6、ablish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specificprecautionary statements, see Section 16.2. Referenced Documents2.1 ASTM Standards:2C 168 Terminology Relating to Thermal InsulationC 177 Test Method for Steady-State
7、Heat Flux Measure-ments and Thermal Transmission Properties by Means ofthe Guarded Hot-Plate ApparatusC 209 Test Methods for Cellulosic Fiber Insulating BoardC 335 Test Method for Steady-State Heat Transfer Proper-ties of Horizontal Pipe InsulationC 390 Practice for Sampling and Acceptance of Therma
8、lInsulation LotsC 518 Test Method for Steady-State Heat Flux Measure-ments and Thermal Transmission Properties by Means ofthe Heat Flow Meter ApparatusC 550 Practice for Measuring Trueness and Squareness ofRigid Block and Board Thermal InsulationC 585 Practice for Inner and Outer Diameters of RigidT
9、hermal Insulation for Nominal Sizes of Pipe and Tubing(NPS System)C 921 Practice for Determining the Properties of JacketingMaterials for Thermal InsulationC 1045 Practice for Calculating Thermal TransmissionProperties Under Steady-State ConditionsC 1058 Practice for Selecting Temperatures for Evalu
10、atingand Reporting Thermal Properties of Thermal InsulationC 1303 Test Method for Estimating Long-Term Change inthe Thermal Resistance of Unfaced Rigid Closed CellPlastic Foams by Slicing and Scaling Under ControlledLaboratory Conditions.C 1363 Test Method for the Thermal Performance of Build-ing As
11、semblies by Means of a Hot Box ApparatusD 1621 Test Method for Compressive Properties of RigidCellular Plastics.D 1622 Test Method for Apparent Density of Rigid CellularPlastics.D 1623 Test Method for Tensile and Tensile AdhesionProperties of Rigid Cellular PlasticsD 2126 Test Method for Response of
12、 Rigid Cellular Plasticsto Thermal and Humid AgingE 84 Test Method for Surface Burning Characteristics ofBuilding MaterialsE 96 Test Methods for Water Vapor Transmission of Mate-rials3. Terminology3.1 The definitions and terms in Terminology C 168 shallapply to this specification.3.2 Definitions of
13、Terms Specific to this Standard1This specification is under the jurisdiction of ASTM Committee C16 onThermal Insulation and is the direct responsibility of Subcommittee C16.22 onOrganic and Nonhomogeneous Inorganic Thermal Insulations.Current edition approved May 1, 2004. Published June 2004. Origin
14、allyapproved in 1989. Last previous edition approved in 2003 as C 1126 03.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe
15、ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.3 Foam Corerigid cellular thermal installation withoutany facers or barriers on the surface of the installation.3.4 Closed Cell Materialfoam where more than 90 % ofthe ce
16、lls are totally enclosed by cell walls, and not intercon-nected with other cells.3.5 Open Cell Materialfoam whose cells are not totallyenclosed by its walls and therefore exhibits a predominance ofinterconnecting cells.4. Classification4.1 The thermal insulation shall be of the following typesand gr
17、ades:4.1.1 Type IFor use as roof insulation board. Producedwithout integral vapor retarder facers.4.1.2 Type IIFor use as sheathing or rigid panel fornon-load bearing applications. Produced with integral vaporretarder facers.4.1.3 Type IIIFor use as pipe insulation. Produced withoutintegral vapor re
18、tarder facers.4.1.4 Grade 1Closed cell material. Foam for Type I ofthis grade will have an apparent thermal conductivity of 0.16Btuin./hft2F (0.023 W/mK) or less and foam for Types IIand III of this grade will have an apparent thermal conductivityof 0.13 Btuin./hft2F (0.019 W/mK) or less at a meante
19、mperature of 75F (24C) when aged in accordance with13.6.1.4.1.5 Grade 2Open cell material. Foam of this grade willhave an apparent thermal conductivity of 0.23 Btuin./hft2F(0.033 W/mK) or less at a mean temperature of 75F (24C).NOTE 2The average thermal conductivities shown in this section arefor cl
20、assification only, not for qualification purposes as indicated bySection 10.1.5. Ordering Information5.1 Orders for materials purchased under this specificationshall include the following information:5.1.1 Designation of this specification.5.1.2 Product name, type, and/or grade.5.1.3 Size and dimens
21、ions.5.1.4 Quantity of material.5.1.5 Special requirements for inspection and/or testing.5.1.6 Pipe insulation jacketing (optional).6. Materials and Manufacture6.1 Foam Core Chemical CompositionThe foam shall beproduced by a chemical reaction of a phenolic resin, surfactant,blowing agent, and other
22、additives as needed.6.2 Facings Facing on Type II material shall be adheredto the core stock and suitable for the service intended. Theyshall be supplied as agreed upon between manufacturer andpurchaser.7. Physical Properties7.1 The material shall conform to the requirements asshown in Table 1.7.2 N
23、ot all physical properties at temperatures below 40F(40C) have been fully tested, and the user should consult themanufacturer for properties and performance at these lowertemperatures.8. Dimensions and Tolerances8.1 DimensionsThe dimensions shall be as agreed uponbetween the purchaser and the suppli
24、er, but commonly shall beas follows:8.1.1 Type IWidth, 24 in., 36 in., or 48 in. (610 mm, 915mm, or 1220 mm). Length, 48 in. or larger (1220 mm orlarger).8.1.2 Type IIWidth, 48 in. (1220 mm). Length, 96 in. orlarger (2440 mm or larger).8.1.3 Type IIIPipe insulation with dimensions that are inaccorda
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC11262004STANDARDSPECIFICATIONFORFACEDORUNFACEDRIGIDCELLULARPHENOLICTHERMALINSULATION 光面 硬质 多孔 酚醛

链接地址:http://www.mydoc123.com/p-463453.html