ASTM C1119-1990(2004)e1 Standard Test Method for Vacuum Drainage of Asbestos-Cement Mixes《石棉水泥混合料真空排放的标准试验方法》.pdf
《ASTM C1119-1990(2004)e1 Standard Test Method for Vacuum Drainage of Asbestos-Cement Mixes《石棉水泥混合料真空排放的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1119-1990(2004)e1 Standard Test Method for Vacuum Drainage of Asbestos-Cement Mixes《石棉水泥混合料真空排放的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1119 90 (Reapproved 2004)e1Standard Test Method forVacuum Drainage of Asbestos-Cement Mixes1This standard is issued under the fixed designation C 1119; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、 revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTEAsbestos warning was moved from 8.1 to 1.3 in September 2004.1. Scope1.1 This test method describes a laboratory procedure fort
3、he evaluation of asbestos fiber by measuring the rate ofdrainage under suction, of an asbestos-cement mixture.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3 WarningBreathing of asbestos dust is hazardous.Asbestos and a
4、sbestos products present demonstrated healthrisks for users and for those with whom they come into contact.In addition to other precautions, when working with asbestos-cement products, minimize the dust that results. For informa-tion on the safe use of chrysoltile asbestos, refer to “Safe Useof Chry
5、sotile Asbestos: A Manual on Preventive and ControlMeasures.”21.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica
6、-bility of regulatory limitations prior to use. See Note 1 and 1.3for specific hazard warnings.2. Referenced Documents2.1 ASTM Standards:3C 150 Specification for Portland CementC 430 Test Method for Fineness of Hydraulic Cement bythe 45-m (No. 325) SieveC 1124 Test Method for Kerosene Retention of A
7、sbestosD 2590 Test Method for Sampling Chrysotile AsbestosD 2946 Terminology for Asbestos and Asbestos-CementProductsD 3752 Test Method for Strength Imparted by Asbestos to aCement MatrixD 3879 Test Method for Sampling Amphibole AsbestosD 3880 Test Method for Asbestos-Fiber Strength UnitE 177 Practi
8、ce for Use of the Terms Precision and Bias inASTM Test Methods2.2 ACS Document:Specifications of the Committee on Analytical Reagents ofthe American Chemical Society43. Terminology3.1 For definitions, refer to Terminology D 2946.4. Summary of Test Method4.1 The fiber to be evaluated is fiberized to
9、simulate thespecific surface area at which it is used in the industrialprocess, and it is added to the same mix using representativeingredients and process water. If the latter is not available,saturated water may be substituted (see 7.7). The slurry isdewatered on a 177-m (No. 80) screen cloth (or
10、in accordancewith the Apparatus Section of Test Method D 3752) under avacuum of 90 kPa (70 cm Hg). The end point is determined asthe point when air begins to pass through the filter cake, andthe suction drops abruptly. The time taken to reach the endpoint is recorded and this is a function of the dr
11、ainage rate ofthe mix.5. Significance and Use5.1 This test method can be used to estimate the speed ofdrainage and the rate of production of products from the fiberevaluated, in industrial applications. It may be applied to singlegrades of fiber, or to fiber blends, together with the same bindersyst
12、em and process water used in the process under evaluation.6. Apparatus6.1 Drainage Apparatus, as described in Fig. 1 and Fig. 2.The funnel shown in Fig. 1 shall be cemented to the bottom ofPart 3 of Fig. 2 to give an air-tight seal. Alternatively, the1This test method is under the jurisdiction of AS
13、TM Committee C-17 onFiber-Reinforced Cement Products and is the direct responsibility of SubcommitteeC17.03 on AsbestosCement Sheet Products and Accessories.Current edition approved June 1, 2004. Published July 2004. Originally approvedin 1989. Last previous edition approved in 1999 as C 1119 90 (19
14、99).2Available from The Asbestos Institute, http:/ referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Available from
15、 American Chemical Society, 1155 16th St. NW, Washington,DC 20036.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.apparatus described in Test Method C 1124 or in Test MethodD 3752, may be used.6.2 Vacuum-Actuated SwitchSet to activat
16、e an electrictimer when the pressure is between 50 kPa (40 cm Hg vacuum)and 8 kPa (70 cm Hg vacuum). This switch shall be located atthe discharge of the drainage funnel, together with a manom-eter of from 0 to 50 kPa absolute (0 to 76 cm Hg vacuum)capacity, and a water trap with a capacity of 500 cm
17、.6.3 Wet Mixer, as shown in Fig. 3, Fig. 4, and Fig. 5, capableof maintaining a speed of 62.8 6 2.6 rad/s (600 6 25 r/min)under load. Alternatively, the mixing apparatus, as described inTest Method D 3880, may be used.6.3.1 The impeller shall rotate clockwise when lookingfrom above, and the vanes sh
18、all be pitched so as to impel theslurry downward.6.3.2 Maximum clearance between the impeller and theconical wall of the wet mixer shall be set at 6.3 mm.6.3.3 The distance between the bottom of the impeller andthe top of the stopper shall be set at 1 6 0.1 cm.6.4 Source of Vacuum,at906 0.2 kPa (70
19、6 0.2 cm Hg).6.5 Fiberizer, such as described in Test Method D 3752.This is needed only if the fiber to be evaluated is not availableat the required degree of fiberization.7. Reagents and Materials7.1 Reagents and Materials(See Note 1 and Note 2.)7.2 Calcium Hydroxide Ca(OH)2, conforming to the ACSS
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC111919902004E1STANDARDTESTMETHODFORVACUUMDRAINAGEOFASBESTOSCEMENTMIXES 石棉 水泥 混合 真空 排放 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-463435.html