ASTM C1116 C1116M-2008 Standard Specification for Fiber-Reinforced Concrete.pdf
《ASTM C1116 C1116M-2008 Standard Specification for Fiber-Reinforced Concrete.pdf》由会员分享,可在线阅读,更多相关《ASTM C1116 C1116M-2008 Standard Specification for Fiber-Reinforced Concrete.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1116/C 1116M 08Standard Specification forFiber-Reinforced Concrete1This standard is issued under the fixed designation C 1116/C 1116M; the number immediately following the designation indicates theyear of original adoption or, in the case of revision, the year of last revision. A numb
2、er in parentheses indicates the year of lastreapproval. A superscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This specification covers all forms of fiber-reinforcedc
3、oncrete that are delivered to a purchaser with the ingredientsuniformly mixed, and that can be sampled and tested at thepoint of delivery. It does not cover the placement, consolida-tion, curing, or protection of the fiber-reinforced concrete afterdelivery to the purchaser.1.2 Certain sections of th
4、is specification are also applicableto fiber-reinforced concrete intended for shotcreting by thedry-mix process when sampling and testing of concrete ispossible only at the point of placement. In this case, thesections dealing with batching plant, mixing equipment, mix-ing and delivery, and measurem
5、ent of workability and aircontent, are not applicable.1.3 This specification does not cover thin-section glassfiber-reinforced concrete manufactured by the spray-up processthat is under the jurisdiction of ASTM Subcommittee C27.40.1.4 The values stated in either SI units or inch-pound unitsare to be
6、 regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.5 The following precautionary statement pertains only
7、tothe test method portion, Sections 15 and 18, of this specifica-tion: This standard does not purport to address all of the safetyconcerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety andhealth practices and determine the appl
8、icability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2A 820/A 820M Specification for Steel Fibers for Fiber-Reinforced ConcreteC 31/C 31M Practice for Making and Curing Concrete TestSpecimens in the FieldC 39/C 39M Test Method for Compressive Strength of Cy-lindr
9、ical Concrete SpecimensC 42/C 42M Test Method for Obtaining and Testing DrilledCores and Sawed Beams of ConcreteC 94/C 94M Specification for Ready-Mixed ConcreteC 125 Terminology Relating to Concrete and ConcreteAggregatesC 138/C 138M Test Method for Density (Unit Weight),Yield, and Air Content (Gra
10、vimetric) of ConcreteC 143/C 143M Test Method for Slump of Hydraulic-Cement ConcreteC 150 Specification for Portland CementC 172 Practice for Sampling Freshly Mixed ConcreteC 173/C 173M Test Method for Air Content of FreshlyMixed Concrete by the Volumetric MethodC 192/C 192M Practice for Making and
11、Curing ConcreteTest Specimens in the LaboratoryC 231 Test Method for Air Content of Freshly MixedConcrete by the Pressure MethodC 387 Specification for Packaged, Dry, Combined Materialsfor Mortar and ConcreteC 567 Test Method for Determining Density of StructuralLightweight ConcreteC 666/C 666M Test
12、 Method for Resistance of Concrete toRapid Freezing and ThawingC 684 Test Method for Making, Accelerated Curing, andTesting Concrete Compression Test SpecimensC 685/C 685M Specification for Concrete Made by Volu-metric Batching and Continuous MixingC 887 Specification for Packaged, Dry, Combined Mat
13、erialsfor Surface Bonding MortarC 995 Test Method for Time of Flow of Fiber-ReinforcedConcrete Through Inverted Slump ConeC 1077 Practice for Laboratories Testing Concrete and Con-crete Aggregates for Use in Construction and Criteria forLaboratory EvaluationC 1140 Practice for Preparing and Testing
14、Specimens fromShotcrete Test Panels1This specification is under the jurisdiction of ASTM Committee C09 onConcrete and Concrete Aggregates and is the direct responsibility of SubcommitteeC09.42 on Fiber-Reinforced Concrete.Current edition approved Jan. 1, 2008. Published February 2008. Originallyappr
15、oved in 1989. Last previous edition approved in 2006 as C 1116/C 1116M 06.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe
16、ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Copyright by ASTM Intl (all rights reserved); Thu Feb 28 01:27:59 EST 2008Downloaded/printed byGuo Dehua (
17、CNIS) pursuant to License Agreement. No further reproductions authorized.C 1385/C 1385M Practice for Sampling Materials for Shot-creteC 1399 Test Method for Obtaining Average Residual-Strength of Fiber-Reinforced ConcreteC 1436 Specification for Materials for ShotcreteC 1480 Specification for Packag
18、ed, Pre-Blended, Dry,Combined Materials for Use in Wet or Dry ShotcreteApplicationC 1550 Test Method for Flexural Toughness of Fiber Rein-forced Concrete (Using Centrally Loaded Round Panel)C 1602/C 1602M Specification for Mixing Water Used inthe Production of Hydraulic Cement ConcreteC 1604/C 1604M
19、 Test Method for Obtaining and TestingDrilled Cores of ShotcreteC 1609/C 1609M Test Method for Flexural Performance ofFiber-Reinforced Concrete (Using Beam With Third-PointLoading)C 1666/C 1666M Specification for Alkali Resistant (AR)Glass Fiber for GFRC and Fiber-Reinforced Concrete andCementD 6942
20、 Test Method for Stability of Cellulose Fibers inAlkaline EnvironmentsD 7357 Specification for Cellulose Fibers for Fiber-Reinforced Concrete2.2 ACI Standards and Reports:211.1 Standard Practice for Selecting Proportions for Nor-mal, Heavyweight, and Mass Concrete3211.2 Standard Practice for Selecti
21、ng Proportions for Struc-tural Lightweight Concrete3506.2 Specification for Materials, Proportioning and Appli-cation of Shotcrete33. Terminology3.1 Definitions3.1.1 For definitions of terms used in this specification, referto Terminology C 125.3.2 Definitions of Terms Specific to This Standard:3.2.
22、1 manufacturer, nthe producer who furnishes thefiber-reinforced concrete.3.2.2 purchaser, nthe owner, or representative thereof,who buys the fiber-reinforced concrete.4. Classification4.1 This specification classifies fiber-reinforced concrete bythe material type of the fiber incorporated.NOTE 1The
23、performance of a fiber-reinforced concrete dependsstrongly upon the susceptibility of the fibers to physical damage during themixing or shotcreting process, their chemical compatibility with thenormally alkaline environment within cement paste, and their resistance toservice conditions encountered w
24、ithin uncracked concrete or as a conse-quence of cracking, involving, for example, carbon dioxide, chlorides, orsulfates in solution with water and oxygen or ultraviolet light in theatmosphere. Improper methods of fiber addition to a concrete mix can leadto balling of some types of fiber; consult ma
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1116C1116M2008STANDARDSPECIFICATIONFORFIBERREINFORCEDCONCRETEPDF

链接地址:http://www.mydoc123.com/p-463427.html