《ASTM C109 C109M-2016a Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in or [50-mm] Cube Specimens)《液压水泥砂浆抗压强度的标准试验方法 (使用2-in 或者[50-mm]立方体试件)》.pdf》由会员分享,可在线阅读,更多相关《ASTM C109 C109M-2016a Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in or [50-mm] Cube Specimens)《液压水泥砂浆抗压强度的标准试验方法 (使用2-in 或者[50-mm]立方体试件)》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C109/C109M 16aStandard Test Method forCompressive Strength of Hydraulic Cement Mortars (Using2-in. or 50-mm Cube Specimens)1This standard is issued under the fixed designation C109/C109M; the number immediately following the designation indicates the yearof original adoption or, in the
2、case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope*1.1 T
3、his test method covers determination of the compres-sive strength of hydraulic cement mortars, using 2-in. or50-mm cube specimens.NOTE 1Test Method C349 provides an alternative procedure for thisdetermination (not to be used for acceptance tests).1.2 This test method covers the application of the te
4、st usingeither inch-pound or SI units. The values stated in either SIunits or inch-pound units are to be regarded separately asstandard. Within the text, the SI units are shown in brackets.The values stated in each system may not be exact equivalents;therefore, each system shall be used independentl
5、y of the other.Combining values from the two systems may result in noncon-formance with the standard.1.3 Values in SI units shall be obtained by measurement inSI units or by appropriate conversion, using the Rules forConversion and Rounding given in IEEE/ASTM SI-10, ofmeasurements made in other unit
6、s.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. (WarningFres
7、hhydraulic cementitious mixtures are caustic and may causechemical burns to skin and tissue upon prolonged exposure.2)2. Referenced Documents2.1 ASTM Standards:3C91 Specification for Masonry CementC114 Test Methods for Chemical Analysis of HydraulicCementC150 Specification for Portland CementC230/C2
8、30M Specification for Flow Table for Use in Testsof Hydraulic CementC305 Practice for Mechanical Mixing of Hydraulic CementPastes and Mortars of Plastic ConsistencyC349 Test Method for Compressive Strength of Hydraulic-Cement Mortars (Using Portions of Prisms Broken inFlexure)C511 Specification for
9、Mixing Rooms, Moist Cabinets,Moist Rooms, and Water Storage Tanks Used in theTesting of Hydraulic Cements and ConcretesC595 Specification for Blended Hydraulic CementsC618 Specification for Coal Fly Ash and Raw or CalcinedNatural Pozzolan for Use in ConcreteC670 Practice for Preparing Precision and
10、Bias Statementsfor Test Methods for Construction MaterialsC778 Specification for Standard SandC989 Specification for Slag Cement for Use in Concrete andMortarsC1005 Specification for Reference Masses and Devices forDetermining Mass and Volume for Use in the PhysicalTesting of Hydraulic CementsC1157
11、Performance Specification for Hydraulic CementC1328 Specification for Plastic (Stucco) CementC1329 Specification for Mortar CementC1437 Test Method for Flow of Hydraulic Cement MortarE4 Practices for Force Verification of Testing Machines2.2 IEEE/ASTM Standard:3IEEE/ASTM SI-10 Standard for Use of th
12、e InternationalSystem of Units (SI): The Modern Metric System3. Summary of Test Method3.1 The mortar used consists of 1 part cement and 2.75 partsof sand proportioned by mass. Portland or air-entrainingportland cements are mixed at specified water/cement ratios.Water content for other cements is tha
13、t sufficient to obtain aflow of 110 6 5 in 25 drops of the flow table. Two-inch or50-mm test cubes are compacted by tamping in two layers.1This test method is under the jurisdiction ofASTM Committee C01 on Cementand is the direct responsibility of Subcommittee C01.27 on Strength.Current edition appr
14、oved March 1, 2016. Published April 2016. Originallyapproved in 1934. Last previous edition approved in 2016 as C109/C109M 16.DOI: 10.1520/C0109_C0109M-16A.2See the section on Safety, Manual of Cement Testing, Annual Book of ASTMStandards, Vol 04.01.3For referenced ASTM standards, visit the ASTM web
15、site, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor
16、Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1The cubes are cured one day in the molds and stripped andimmersed in lime water until tested.4. Significance and Use4.1 This test method provides a means of determining thecompressive strength of hydraulic cement and other mortarsan
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC109C109M2016ASTANDARDTESTMETHODFORCOMPRESSIVESTRENGTHOFHYDRAULICCEMENTMORTARSUSING2INOR50MMCUBESPECIMENS

链接地址:http://www.mydoc123.com/p-463329.html