ASTM C1087-2000(2006) Standard Test Method for Determining Compatibility of Liquid-Applied Sealants with Accessories Used in Structural Glazing Systems《测定门窗玻璃结构装置中与附件一同使用的液态密封料相容性的.pdf
《ASTM C1087-2000(2006) Standard Test Method for Determining Compatibility of Liquid-Applied Sealants with Accessories Used in Structural Glazing Systems《测定门窗玻璃结构装置中与附件一同使用的液态密封料相容性的.pdf》由会员分享,可在线阅读,更多相关《ASTM C1087-2000(2006) Standard Test Method for Determining Compatibility of Liquid-Applied Sealants with Accessories Used in Structural Glazing Systems《测定门窗玻璃结构装置中与附件一同使用的液态密封料相容性的.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1087 00 (Reapproved 2006)Standard Test Method forDetermining Compatibility of Liquid-Applied Sealants withAccessories Used in Structural Glazing Systems1This standard is issued under the fixed designation C 1087; the number immediately following the designation indicates the year ofor
2、iginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers a laboratory screening proce-dure fo
3、r determining the compatibility of liquid-applied struc-tural sealant glazing sealants when in contact with accessoriessuch as dry glazing gaskets, spacers, shims, and setting blocksafter exposure to heat and ultraviolet light.1.2 This test method includes the observation of threeparameters as follo
4、ws:1.2.1 Changes in the color of the sealant,1.2.2 Changes in the adhesion of the sealant to glass, and1.2.3 Changes in the adhesion of the sealant to the accessorybeing tested.1.3 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonl
5、y.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1At this
6、 time, no comparable ISO standard exists.2. Referenced Documents2.1 ASTM Standards:2C 717 Terminology of Building Seals and Sealants3. Terminology3.1 DefinitionsDefinitions of the following terms used inthis test method are listed in Terminology C 717: adhesivefailure (adhesion loss), bead, bond bre
7、aker, cohesive failure,compatibility, gasket, glazing, sealant, setting blocks, shim,spacer, structural sealant, and structural sealant glazing.4. Summary of Test Method4.1 The test specimens are placed beneath ultraviolet lampsso that the radiation will hit the sealant directly on onespecimen, and
8、through the glass, on the other specimen (seeFig. 1).4.2 The control specimens for this test method are preparedand tested identically to the test specimens except that theaccessory is eliminated.4.3 After the specimens are exposed, the test specimens arecompared to the control specimens.4.4 In the
9、testing of the specimens, any color change in thesealant between the test specimen and the control is noted asare any changes in the adhesion of the sealant to either the glassor to the accessory. This test method requires the preparation ofeight test specimens (four controls and four test specimens
10、 foreach accessory being evaluated).5. Significance and Use5.1 In structural sealant glazing systems, the sealant func-tions as the structural adhesive and may also function as theprimary weather seal. As the structural adhesive, the integrityof the adhesive bond is critical.5.2 Changes in color and
11、 adhesion after exposure are two ofthe criteria that can be used to determine the compatibility ofthe system. Experience has shown that accessories that causeloss of adhesion or discoloration in this test method may alsocause these occurrences in actual use.6. Apparatus and Materials6.1 Glass Panels
12、, clear float glass, approximately 76.2 by50.8 by 6.4 mm (3 by 2 by14 in.). Eight panels are required foreach material being tested.6.2 Bond Breaker Tape, 25.4 by 76.2-mm (1 by 3-in.) piecefor each panel. The bond breaker tape must be compatible withthe sealants being tested.6.3 Thermometer, for exa
13、mple, 28.9 to 100C (20 to 212F).6.4 Ultraviolet (UV) lamps, UVA-340 lamps.1This test method is under the jurisdiction ofASTM Committee C24 on BuildingSeals and Sealants and is the direct responsibility of Subcommittee C24.20 onGeneral Test Methods.Current edition approved May 1, 2006. Published Augu
14、st 2006. Originallyapproved in 1987. Last previous edition approved in 2000 as C 1087 00.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summ
15、ary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.5 UV Exposure ApparatusA suitable UV exposure ap-paratus will consist of four UVA-340 lamps in a symmetricalarray situated 254 mm (12 in.) from the surface
16、 of the testspecimens (see Fig. 2). The apparatus shall be capable ofmaintaining a temperature at the test specimens of 48 6 2C(118 6 3.6F). Infrared lamps or other sources of heat may beused to maintain the required temperature.6.6 Cleaning SolventAny solvent capable of cleaning theglass is accepta
17、ble (for example, 50/50 mix of isopropylalcohol and distilled water).6.7 Test Sealant, an appropriate amount of the sealant to beused in the system.6.8 Reference SealantA light or translucent sealant of thesame composition as the test sealant. If none is available,contact the sealant supplier for re
18、commendations on a suitablealternative.7. Preparation of Test Specimens7.1 Standard conditions of temperature and relative humid-ity used during the preparation are defined as 23 6 2C (73.463.6F) and 50 6 10 % relative humidity.7.2 Prior to use, clean the glass thoroughly with the cleaningsolvent an
19、d dry with a clean rag before the solvent is allowedto evaporate.7.3 Place a piece of compatible bond breaker tape to cover1 in. of the top surface of the glass at one end (see Fig. 3).7.4 Prepare a total of eight samples (four controls withoutaccessory and four test specimens with accessory).3Cut a
20、 pieceof accessory material approximately 6.4 by 51 by 6.4 mm (14by2by14 in.) and place it on the center of the piece of glassas shown in Fig. 3. Both the reference sealant and the testsealant are tested in contact with the accessory.7.5 Apply a bead of the test sealant on one side of theaccessory a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC108720002006STANDARDTESTMETHODFORDETERMININGCOMPATIBILITYOFLIQUIDAPPLIEDSEALANTSWITHACCESSORIESUSEDINSTRUCTURALGLAZINGSYSTEMS

链接地址:http://www.mydoc123.com/p-463303.html