1、Designation: C1086 09 (Reapproved 2016)Standard Specification forGlass Fiber Mechanically Bonded Felt Thermal Insulation1This standard is issued under the fixed designation C1086; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、 year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers glass fiber unsupportedneedled felt (mechanically bonded) binder-free insulation fo
3、rthermal insulation. This material is used as the thermalinsulation component in the fabrication of insulation systemsfor use on machinery and equipment, such as steam turbines,boilers, boiler feed pumps, and piping at temperatures fromambient up to 1200F (650C).1.2 This standard does not purport to
4、 address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1.3 The values stated in inch-pound units are to be
5、regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.4 See Supplementary Requirements for modifications toparagraphs in this standard when using Specification C1086 inlieu of the United St
6、ates Department of Defense, Departmentof Navy, Naval Sea Systems Command, in Washington, DC.Military Specifications No.(s) MIL-I-16411F.2. Referenced Documents2.1 ASTM Standards:2C167 Test Methods for Thickness and Density of Blanket orBatt Thermal InsulationsC168 Terminology Relating to Thermal Ins
7、ulationC177 Test Method for Steady-State Heat Flux Measure-ments and Thermal Transmission Properties by Means ofthe Guarded-Hot-Plate ApparatusC335 Test Method for Steady-State Heat Transfer Propertiesof Pipe InsulationC390 Practice for Sampling and Acceptance of ThermalInsulation LotsC411 Test Meth
8、od for Hot-Surface Performance of High-Temperature Thermal InsulationC518 Test Method for Steady-State Thermal TransmissionProperties by Means of the Heat Flow Meter ApparatusC1045 Practice for Calculating Thermal Transmission Prop-erties Under Steady-State ConditionsC1058 Practice for Selecting Tem
9、peratures for Evaluatingand Reporting Thermal Properties of Thermal InsulationD123 Terminology Relating to TextilesD578 Specification for Glass Fiber Strands2.2 U.S. Federal Standard:FED-STD-191 Textile Test Methods32.3 U.S. Military Standards:MIL-I-16411F Insulation Felt, Thermal, Glass Fiber3MIL-S
10、TD-1623 Fire Performance Requirements and Ap-proved Specifications for Interior Finish Materials andFurnishings (Naval Shipboard Use)33. Terminology3.1 Definitions:3.1.1 Terminology C168 and D123 shall be considered asapplying to the terms used in this specification.3.1.2 Definitions in Specificatio
11、n D578 shall be consideredas applying to the terms used in defining glass fiber composi-tion code, process, and fiber diameter.4. Classification4.1 Thermal insulation shall be glass fiber, unsupportedneedled felt insulation, for use on surfaces with temperaturesup to 1200F (650C).5. Ordering Informa
12、tion5.1 The purchase order or contract shall specify the follow-ing:5.1.1 Quantity of each thickness (10.1).5.1.2 Any special requirements for nonstandard sizes ordimensions (10.2 and 10.3).5.1.3 Any requirements for certification (19.1).1This specification is under the jurisdiction of ASTM Committe
13、e C16 onThermal Insulation and is the direct responsibility of Subcommittee C16.23 onBlanket and Loose Fill Insulation.Current edition approved Nov. 15, 2016. Published December 2016. Originallyapproved in 1987. Last previous edition approved in 2009 as C1086 09. DOI:10.1520/C1086-09R16.2For referen
14、ced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Standardization Documents Order Desk, DODSSP, Bldg. 4,Sec
15、tion D, 700 Robbins Ave., Philadelphia, PA 19111-5098, http:/www.dodssp.daps.mil.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on stan
16、dardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.15.1.4 Any special requirements for supplementary testingrequirements (9.1). and5.1.5 Any
17、 special packaging information.6. Materials and Manufacture6.1 The material shall consist of 100 % glass fiber needledinto insulation felts without the use of binders. No organicfibers and no glass or mineral shot shall be included in theproduct. It is acceptable for the insulation felt to be compos
18、edof laminates formed without the use of binders.The glass fibersshall meet the designation C, Continuous Filament Yarns, inaccordance with Specification D578 (see Note 1).6.2 The fiber diameter of the glass fiber used in the finalproduct, when determined in accordance with the FilamentDiameter sect
19、ion of Specification D578 shall conform to therequirements of Table 1. The certification of the diameter of thefiber is to be provided in one of two ways: either by the feltmanufacturer or by certification of the glass fiber supplier anddocumentation by the manufacturer as to sources of supply.6.3 A
20、ll materials used shall be asbestos and ceramic (refrac-tory) fiber-free.NOTE 1The fibers from glass composition designated as “E” glass(electrical glass) in the range from D through G meet the requirements ofTables 1 and 2.7. Physical Properties7.1 When tested in accordance with Section 16, the ins
21、ula-tion shall conform to the physical requirements listed in Table2.8. Performance Characteristics8.1 Any of the following conditions can result in damage tothe needled glass fiber insulation:8.1.1 Direct exposure to hydrofluoric acid.8.1.2 Prolonged direct exposure to strong caustics.8.1.3 Prolong
22、ed exposure to boiling water.8.2 Conditions outlined in 8.1 are mentioned only to makethe user aware of such applications that require specialconsideration. Contact the insulation manufacturer for recom-mendations when the above conditions are anticipated.9. Other Requirements9.1 Supplementary requi
23、rements include qualification testsand acceptance tests to special standards. These supplementaryrequirements are made by agreement to the supplier and thepurchaser only when specified in the purchase order orcontract.10. Standard Sizes and Dimensions10.1 ThicknessThe insulation shall be furnished i
24、n thethicknesses shown in Table 3.10.2 Insulation LengthUnless otherwise specified, theinsulation shall be furnished in rolls of the lengths given inTable 3.10.3 Insulation WidthUnless otherwise specified (5.1.2),the width of the insulation shall be 60 in. (1.52 m).10.4 Nominal Mass per AreaThe insu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC108620092016STANDARDSPECIFICATIONFORGLASSFIBERMECHANICALLYBONDEDFELTTHERMALINSULATION 玻璃纤维 机械 粘合

链接地址:http://www.mydoc123.com/p-463302.html