ASTM C1080-1998(2003)e1 Standard Specification for Asbestos-Cement Products Other Than Fill For Cooling Towers《冷却塔用除填料以外的石棉水泥制品》.pdf
《ASTM C1080-1998(2003)e1 Standard Specification for Asbestos-Cement Products Other Than Fill For Cooling Towers《冷却塔用除填料以外的石棉水泥制品》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1080-1998(2003)e1 Standard Specification for Asbestos-Cement Products Other Than Fill For Cooling Towers《冷却塔用除填料以外的石棉水泥制品》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1080 98 (Reapproved 2003)e1Standard Specification forAsbestos-Cement Products Other Than Fill For CoolingTowers1This standard is issued under the fixed designation C 1080; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisi
2、on, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTEAsbestos warning statement was added to 1.4 in September 2004.1. Scope1.1 This specification covers drift e
3、liminators or demisters,louvers, partitioning and casing panels.NOTE 1Asbestos-cement pipes are covered in Specifications C 296and C 428; and asbestos-cement heat exchange fill products are covered inSpecification C 1082 for flat fill and Specification C 1081 for corrugatedfill.1.2 The following cla
4、sses of products are covered:Paragraph ClassificationsDrift eliminators or demisters 4.1 Classes 1, 2 and 3Louvers 4.2 Classes 1 and 2Casing panels 4.3 Classes 1 and 2Asbestos-cement pressurepipes4.4 Classes 100, 150, and 200Asbestos-cement nonpressureor gravity drainage pipes4.5 Classes 1500, 2400,
5、 3300,4000, and 50001.2.1 Products cured at atmospheric pressure or by auto-claving are covered.1.3 The values stated in the SI system are to be regarded asthe standard. The inch-pound units in parentheses are providedfor information only.1.4 WarningBreathing of asbestos dust is hazardous.Asbestos a
6、nd asbestos products present demonstrated healthrisks for users and for those with whom they come into contact.In addition to other precautions, when working with asbestos-cement products, minimize the dust that results. For informa-tion on the safe use of chrysoltile asbestos, refer to “Safe Useof
7、Chrysotile Asbestos: A Manual on Preventive and ControlMeasures.”21.5 The following safety hazards caveat pertains only to thetest method portion of this specification (Section 5): Thisstandard does not purport to address all of the safety concerns,if any, associated with its use. It is the responsi
8、bility of the userof this standard to establish appropriate safety and healthpractices and to determine the applicability of regulatorylimitations prior to use. For a specific safety hazard, see 1.4.2. Referenced Documents2.1 ASTM Standards:3C 150 Specification for Portland CementC 220 Specification
9、 for Flat Asbestos-Cement SheetsC 221 Specification for Corrugated Asbestos-CementSheetsC 223 Specification for Asbestos-Cement SidingC 296 Specification for Asbestos-Cement Pressure PipeC 428 Specification for Asbestos-Cement NonpressureSewer PipeC 458 Test Method for Organic Fiber Content of Asbes
10、tos-Cement ProductsC 459 Test Methods for Asbestos-Cement Flat Products.C 1081 Specification for Asbestos-Cement Corrugated Fillfor Use in Cooling TowersC 1082 Specification for Asbestos-Cement Flat Sheet forCooling Tower FillD 2946 Terminology for Asbestos and Asbestos-CementProducts2.2 DIN Standar
11、d:DIN 274 Asbestzement-Weilplatten43. Terminology3.1 DefinitionsThe definitions covered in TerminologyD 2946 are applicable to this specification.3.2 Definitions of Terms Specific to This Standard:3.2.1 autoclaved productsthose that have been treated in asaturated steam atmosphere at between 689 and
12、 1517 kPa (100and 220 psi) for at least 8 h, and that contain portland cementType I as defined in Specification C 150 together with silica inthe ratio of 3:2 that can react to form calcium silicate reactionproducts.1This specification is under the jurisdiction of ASTM Committee C17 onFiber-Cement Pr
13、oducts and is the direct responsibility of Subcommittee C17.03 onAsbestos-Cement Sheet Products and Accessories.Current edition approved Jan. 10, 2003. Published July 2003. Originallyapproved in 1987. Last previous edition approved in 1998 as C 1080 98.2Available from The Asbestos Institute, http:/
14、referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Available from Deutsches Institut fr Normunge, Beuth Verlag GmbH,
15、 Aus-lieferung, Post Fach 1107, D-1000 Berlin 30, Germany.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.3 pressed productsinclude those that are pressed singlyor in stacks interlayered with templates, at a minimum pressureof 12 M
16、Pa (1740 psi).4. Classifications4.1 Drift Eliminators or Demisters:4.1.1 Class A drift eliminator materials consist of corrugatedpanels that conform to the following requirements:Nominal thickness 6.5 mm (14 in.)Pitch 177 mm (7 in.)Minimum deflection (in accordance withTest Methods C 459)2.2 mm (0.1
17、 in.)Minimum average bendingMoment calculated as in DIN 274: 1650 Nm/m (370 ft-lbf/ft)Minimum individual specimen bendingMoment 1400 Nm/m (315 ft-lbf/ft)4.1.2 Class B drift eliminator materials consist of corru-gated panels that conform to the following requirements:Nominal thickness 5 mm ( 3/16 in.
18、)Pitch 155 mm (7 in.)Deflection, minimum (in accordancewith Test Methods C 459)3.3 mm (0.13 in.)Minimum average bendingMoment calculated as in DIN 274 1400 Nm/m (315 ft-lbf/ft)Minimum individual specimen bendingMoment 1190 Nm/m (266 ft-lbf/ft)4.1.3 Class C drift eliminator materials consist of flat
19、sheetsor clapboards that conform to Specifications C 220 (Type F), orC 223, in addition to requirements in 4.1.4.4.1.4 Additional Requirements:Minimum thickness 7 mm (0.272 in.)Minimum apparent density 1.5 g/cm3(94 lb/ft3).4.2 Louvers:4.2.1 Class ALouver materials consisting of corrugatedsheets that
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC108019982003E1STANDARDSPECIFICATIONFORASBESTOSCEMENTPRODUCTSOTHERTHANFILLFORCOOLINGTOWERS 冷却塔 填料

链接地址:http://www.mydoc123.com/p-463285.html