ASTM C1063-2008 Standard Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-Based Plaster《内外侧置放硅酸盐水泥基灰泥的板条和衬条的安装标准规范》.pdf
《ASTM C1063-2008 Standard Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-Based Plaster《内外侧置放硅酸盐水泥基灰泥的板条和衬条的安装标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1063-2008 Standard Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-Based Plaster《内外侧置放硅酸盐水泥基灰泥的板条和衬条的安装标准规范》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1063 08Standard Specification forInstallation of Lathing and Furring to Receive Interior andExterior Portland Cement-Based Plaster1This standard is issued under the fixed designation C 1063; the number immediately following the designation indicates the year oforiginal adoption or, in
2、 the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 T
3、his specification covers the minimum requirements forlathing and furring for the application of exterior and interiorportland cement-based plaster as in Specification C 926 orSpecification C 841.1.2 Where a fire resistance rating is required for plasteredassemblies and constructions, details of cons
4、truction shall be inaccordance with reports of fire tests of assemblies that havemet the requirements of the fire rating imposed.1.3 Where a specific degree of sound control is required forplastered assemblies and constructions, details of constructionshall be in accordance with official reports of
5、tests conducted inrecognized testing laboratories in accordance with the appli-cable requirements of Test Method E90.1.4 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information only
6、and are not considered standard.2. Referenced Documents2.1 ASTM Standards:2A 641/A 641M Specification for ZincCoated (Galvanized)Carbon Steel WireA 653/A 653M Specification for Steel Sheet, Zinc-Coated(Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed)by the Hot-Dip ProcessB69 Specification for Ro
7、lled ZincB 221 Specification for Aluminum and Aluminum-AlloyExtruded Bars, Rods, Wire, Profiles, and TubesC11 Terminology Relating to Gypsum and Related Build-ing Materials and SystemsC 841 Specification for Installation of Interior Lathing andFurringC 847 Specification for Metal LathC 926 Specifica
8、tion for Application of Portland Cement-Based PlasterC 933 Specification for Welded Wire LathC 954 Specification for Steel Drill Screws for the Applica-tion of Gypsum Panel Products or Metal Plaster Bases toSteel Studs from 0.033 in. (0.84 mm) to 0.112 in. (2.84mm) in ThicknessC 1002 Specification f
9、or Steel Self-Piercing TappingScrews for the Application of Gypsum Panel Products orMetal Plaster Bases to Wood Studs or Steel StudsC 1032 Specification for Woven Wire Plaster BaseD 1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)Compounds and Chlorinated Poly(Vinyl Chloride)(CPVC) CompoundsD
10、 4216 Specification for Rigid Poly(Vinyl Chloride) (PVC)and Related PVC and Chlorinated Poly(Vinyl Chloride)(CPVC) Building Products CompoundsE90 Test Method for Laboratory Measurement of AirborneSound Transmission Loss of Building Partitions and Ele-ments3. Terminology3.1 DefinitionsFor definitions
11、 relating to Ceilings andWalls, see Terminology C11.3.2 Definitions of Terms Specific to This Standard:3.2.1 control joint, na joint that accommodates movementof plaster shrinkage and curing along predetermined, usuallystraight, lines.3.2.2 expansion joint, na joint that accommodates move-ment beyon
12、d plaster shrinkage and curing.1This specification is under the jurisdiction of ASTM Committee C11 onGypsum and Related Building Materials and Systems and is the direct responsibilityof Subcommittee C11.03 on Specifications for theApplication of Gypsum and OtherProducts in Assemblies.Current edition
13、 approved May 15, 2008. Published June 2008. Originallyapproved in 1986. Last previous edition approved in 2007 as C 1063 07.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information,
14、refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.NOTE 1For design consideration of control and expansion
15、 joints, seeAnnex A2.3.1.2 of Specification C 926.3.2.3 hangers, nwires or steel rods or straps used tosupport main runners for suspended ceilings beneath floor orroof constructions.3.2.4 inserts, ndevices embedded in concrete structuralmembers to provide a loop or opening for attachment ofhangers.3
16、.2.5 saddle tie, nsee Figs. 1 and 2.3.2.6 self-furring, adja metal plaster base manufacturedwith evenly-spaced indentations that hold the body of the lathapproximately14 in. (6.4 mm) away from solid surfaces towhich it is applied.3.2.7 framing member, nstuds, joist, runners (track),bridging, bracing
17、, and related accessories manufactured orsupplied in wood or light gauge steel.4. Delivery of Materials4.1 All materials shall be delivered in the original packages,containers, or bundles bearing the brand-name and manufac-turers (or suppliers) identification.5. Storage of Materials5.1 All materials
18、 shall be kept dry. Materials shall bestacked off the ground, supported on a level platform, andprotected from the weather and surface contamination.5.2 Materials shall be neatly stacked with care taken toavoid damage to edges, ends, or surfaces.5.3 Paper backed metal plaster bases shall be handledc
19、arefully in delivery, storage, and erection to prevent punctur-ing or removal of paper.6. Materials6.1 Metal Plaster Bases:6.1.1 Expanded Metal LathSpecification C 847, galva-nized.6.1.2 Wire Laths:6.1.2.1 Welded Wire LathSpecification C 933.6.1.2.2 Woven Wire LathSpecification C 1032.6.1.2.3 Paper
20、Backed Plaster BasesSpecification C 847.6.2 Accessories:6.2.1 GeneralAll accessories shall have perforated orexpanded flanges or clips shaped to permit complete embed-ment in the plaster, to provide means for accurate alignment,and to secure attachment of the accessory to the underlyingsurface.Acces
21、sories shall be designed to receive application ofthe specified plaster thickness.6.2.2 Accessories shall be fabricated from ZincAlloy (99 %pure zinc), galvanized (zinc coated) steel, rigid PVC or CPVCplastic, or anodized aluminum alloy. See Specification B 221.(See Table 1 for minimum allowable thi
22、cknesses).NOTE 2The selection of an appropriate type of material for accesso-ries shall be determined by applicable surrounding climatic and environ-mental conditions specific to the project location, such as salt air,industrial pollution, high moisture, or humidity.6.2.3 SteelSpecification A 653/A
23、653M and shall have aG60 coating.6.2.4 PVC PlasticSpecification D 1784 or D 4216.6.2.5 Zinc AlloySpecification B69, 99 % pure zinc.6.2.6 Thickness of base material shall be as shown in Table1.6.2.7 Cornerite1.75 lb/yd2(0.059 kg/m2), galvanized ex-panded metal lath, galvanized, 1.7 lb/yd2(0.057 kg/m2
24、) galva-nized woven or welded wire fabric of 0.0410 in. (1.04 mm)wire. When shaped for angle reinforcing, it shall have out-standing flanges (legs) of not less than 2 in. (51 mm).6.3 ChannelsShall be cold-formed from steel with mini-mum 33 000 psi (228 MPa) yield strength and 0.0538 in. (1.37mm) min
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC10632008STANDARDSPECIFICATIONFORINSTALLATIONOFLATHINGANDFURRINGTORECEIVEINTERIORANDEXTERIORPORTLANDCEMENTBASEDPLASTER

链接地址:http://www.mydoc123.com/p-463187.html