ASTM C1058-2003(2008) Standard Practice for Selecting Temperatures for Evaluating and Reporting Thermal Properties of Thermal Insulation《为评价和报告绝热材料热性能选择温度的标准方法》.pdf
《ASTM C1058-2003(2008) Standard Practice for Selecting Temperatures for Evaluating and Reporting Thermal Properties of Thermal Insulation《为评价和报告绝热材料热性能选择温度的标准方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1058-2003(2008) Standard Practice for Selecting Temperatures for Evaluating and Reporting Thermal Properties of Thermal Insulation《为评价和报告绝热材料热性能选择温度的标准方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1058 03 (Reapproved 2008)Standard Practice forSelecting Temperatures for Evaluating and ReportingThermal Properties of Thermal Insulation1This standard is issued under the fixed designation C 1058; the number immediately following the designation indicates the year oforiginal adoption
2、 or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers standard mean temperatures forreporting thermal propert
3、ies of thermal insulations, products,and materials, and of related systems and components, bothinsulated and uninsulated.1.2 Thermal properties shall be determined as a function oftemperature by standard test methods. (Test Methods C 177,C 201, C 236, C 335, C 518, C 745, C 976, C 1114, GuideC 653,
4、and Practice C 687, all in combination with PracticeC 1045.)NOTE 1Standard referenced materials are needed to span the tem-perature range of the tests.1.3 This practice recommends standard conditions for use intesting and evaluating thermal properties as a function oftemperature by standard test met
5、hods.1.4 General applications of thermal insulations include:1.4.1 Building envelopes,1.4.2 Mechanical systems or processes, and1.4.3 Building and industrial insulations.1.5 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly. Appr
6、oximate inch-pound units are provided in the tables.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of
7、 regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 168 Terminology Relating to Thermal InsulationC 177 Test Method for Steady-State Heat Flux Measure-ments and Thermal Transmission Properties by Means ofthe Guarded-Hot-Plate ApparatusC 201 Test Method for Thermal Condu
8、ctivity of Refracto-riesC 335 Test Method for Steady-State Heat Transfer Proper-ties of Pipe InsulationC 518 Test Method for Steady-State Thermal TransmissionProperties by Means of the Heat Flow Meter ApparatusC 653 Guide for Determination of the Thermal Resistanceof Low-Density Blanket-Type Mineral
9、 Fiber InsulationC 687 Practice for Determination of Thermal Resistance ofLoose-Fill Building InsulationC 745 Test Method for Heat Flux Through Evacuated Insu-lations Using a Guarded Flat Plate Boiloff CalorimeterC 1045 Practice for Calculating Thermal TransmissionProperties Under Steady-State Condi
10、tionsC 1114 Test Method for Steady-State Thermal TransmissionProperties by Means of the Thin-Heater ApparatusC 1363 Test Method for Thermal Performance of BuildingMaterials and Envelope Assemblies by Means of a HotBox Apparatus3. Terminology3.1 Definitions For definitions of terms and symbols usedin
11、 this practice, refer to Terminology C 168.4. Significance and Use4.1 The various methods for measuring and calculatingthermal properties provide data and information for manufac-turers published information, for comparison of related prod-ucts, and for designers and users to evaluate insulation pro
12、d-ucts for particular applications. For these purposes it isadvisable to provide basic data and information producedunder standard temperature conditions.4.2 Thermal properties of a specimen may change withmean temperature, with temperature difference across thespecimens, and with high temperature e
13、xposure. Data andinformation at standard temperatures are necessary for validcomparison of thermal properties.4.3 The mean test temperatures to measure thermal proper-ties shall be selected from those listed in Table 1.Itisrecommended that thermal properties of insulation materials beevaluated over
14、a mean temperature range that represents theintended end use. For this situation, the lowest and greatest1This practice is under the jurisdiction of ASTM Committee C16 on ThermalInsulation and is the direct responsibility of Subcommittee C16.30 on ThermalMeasurement.Current edition approved Aug. 1,
15、2008. Published August 2008. Originallyapproved in 1986. Last previous edition approved 2003 as C 1058 03.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standa
16、rds Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.mean temperatures should be within 10C of the maximum andminimum mean temperature of interest. The temperature dif-ferences for any chosen m
17、ean temperature will depend uponboth the thermal insulation application (see appropriate mate-rials specification), the method of evaluation, and the limita-tions of the apparatus. Temperature differences or relevanttemperatue conditions required by ASTM material specifica-tions shall take precedenc
18、e over those recommended in thispractice.4.3.1 Standard conditions are presented where both surfacesare exposed to fixed ambient temperatures that are typical fortesting building constructions, both insulated and uninsulated(Table 2).4.3.2 Standard conditions are presented where the tempera-tures of
19、 the two surfaces are fixed and surface coefficients arenot considered (Table 3).4.3.3 For conditions where the temperature of only onesurface is fixed with the other exposed to fixed ambienttemperature, use the mean temperatures of Table 1.4.4 These conditions must be stated to describe accuratelyt
20、hermal properties such as thermal conductivity versus meantemperature for thermal insulating materials. Thermal insula-tions exhibiting inflection points due to the change of state ofinsulating gases (see Note 2), must be tested at sufficientlysmall temperature differences between (1) the hot and co
21、ldsides and (2) between mean temperatures. The test temperaturedifferences used depend on the vapor pressure versus tempera-ture relationship of the gases involved and the ability of the testapparatus to provide accurate measurements of low tempera-ture differences.NOTE 2Certain closed-cell cellular
22、 plastic insulations are of this type.5. Procedure5.1 Since there are distinctly different needs or uses forthermal performance information, the test conditions selectedmust be appropriate to the need or use.5.2 Determine the use classification described in 5.3 andchoose the appropriate temperature
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC105820032008STANDARDPRACTICEFORSELECTINGTEMPERATURESFOREVALUATINGANDREPORTINGTHERMALPROPERTIESOFTHERMALINSULATION

链接地址:http://www.mydoc123.com/p-463174.html