ASTM C10 C10M-2014 Standard Specification for Natural Cement《天然水泥标准规格》.pdf
《ASTM C10 C10M-2014 Standard Specification for Natural Cement《天然水泥标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM C10 C10M-2014 Standard Specification for Natural Cement《天然水泥标准规格》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C10/C10M 14Standard Specification forNatural Cement1This standard is issued under the fixed designation C10/C10M; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indic
2、ates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers natural cement and quick-setting natural cement.NOTE 1Examples of typical past uses of natural cement include unitmasonry mortar, cemen
3、t plaster, grout, whitewash, and concrete.1.2 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two
4、systems may result in non-conformancewith the standard. Values in SI units or inch-pound units shallbe obtained by measurement in SI units or inch-pound unitsor by appropriate conversion, using the Rules for Conversionand Rounding given in IEEE/ASTM SI 10, of measurementsmade in other units or SI un
5、its. Values are stated in only SIunits when inch-pound units are not used in practice.1.3 The text of this standard references notes and footnoteswhich provide explanatory material. These notes and footnotes(excluding those in tables and figures) shall not be consideredas requirements of the standar
6、d.2. Referenced Documents2.1 ASTM Standards:2C109/C109M Test Method for Compressive Strength ofHydraulic Cement Mortars (Using 2-in. or 50-mm CubeSpecimens)C114 Test Methods for Chemical Analysis of HydraulicCementC150 Specification for Portland CementC151 Test Method for Autoclave Expansion of Hydr
7、aulicCementC183 Practice for Sampling and the Amount of Testing ofHydraulic CementC185 Test Method for Air Content of Hydraulic CementMortarC187 Test Method for Amount of Water Required for Nor-mal Consistency of Hydraulic Cement PasteC188 Test Method for Density of Hydraulic CementC191 Test Methods
8、 for Time of Setting of Hydraulic Cementby Vicat NeedleC204 Test Methods for Fineness of Hydraulic Cement byAir-Permeability ApparatusC219 Terminology Relating to Hydraulic CementC305 Practice for Mechanical Mixing of Hydraulic CementPastes and Mortars of Plastic ConsistencyC465 Specification for Pr
9、ocessing Additions for Use in theManufacture of Hydraulic CementsC688 Specification for Functional Additions for Use inHydraulic CementsC778 Specification for SandC786 Test Method for Fineness of Hydraulic Cement andRaw Materials by the 300-m (No. 50), 150-m (No.100), and 75-m (No. 200) Sieves by We
10、t MethodsIEEE/ASTM SI 10 Standard for Use of the InternationalSystem of Units (SI): The Modern Metric System3. Terminology3.1 For definitions of terms related to this specification, seeTerminology C219.4. Ordering Information4.1 Orders for material under this specification shall includethe following
11、:4.1.1 This specification number and date, and4.1.2 Optional physical requirements as given in 7.2.5. Additions5.1 The cement covered by this specification shall containno addition except as follows:5.1.1 Water, or calcium sulfate, or both.5.1.2 Processing additions used in the manufacture of thecem
12、ent shall have been shown to meet the requirements ofSpecification C465 in the amounts used or greater.5.1.3 Functional additions shall have been shown to meetthe requirements of Specification C688 when tested with thecement to be used in the amounts used or greater.1This test method is under the ju
13、risdiction of ASTM Committee C01 on Cementand is the direct responsibility of Subcommittee C01.10 on Hydraulic Cements forGeneral Concrete Construction.Current edition approved Jan. 1, 2014. Published March 2014. Originallyapproved in 1904. Last previous edition approved in 2013 as C10/C10M13. DOI:1
14、0.1520/C0010_C0010M-14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears
15、at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16. Chemical Requirements6.1 Natural cements shall conform to the standard chemicalrequirements in Table 1.7. Physical Requirements7.1 Natural cements and quick
16、-setting natural cements shallconform to the respective standard physical requirementsprescribed in Table 1.NOTE 2Time of setting requirements for natural cements havechanged over time. Requirements of previous editions of this standard areas follows:1904-1937: Minimum 10 min initial setting, minimu
17、m 30 min finalsetting1937-1954: Minimum 10 min initial setting (Vicat) or 20 min(Gillmore) and maximum 10 h final setting1954-1962: Minimum 10 min and maximum 6 h initial setting (TestMethod C191)1962-1970: Minimum 60 min initial setting and maximum 12 h finalsetting (Gillmore)1970-1976 and 2006-200
18、8: Minimum 30 min initial setting (Vicat)2009: Minimum 30 min initial settingNatural Cement; Minimum10 min initial setting, maximum 30 min initial setting, and minimum 30min final settingQuick Setting Natural Cement7.2 In order to match historic cements, at the option of thepurchaser, the required v
19、alues for % retention on the 300-m(N0. 50), 150-m (No. 100), and 75-m (No. 200) sieves, or ofair permeability fineness shall be agreed at time of placing theorder.NOTE 3If no data on historic cement fineness are available, thepurchaser may wish to consider that previous editions of this specificatio
20、nfrom 1904 to 1976 required minimum values as follows:1954-1976: Minimum 550 m2/kg fineness (air-permeability method)1937-1954: Maximum 15% retained on a 75-m (No. 200) sieve1904-1937: Maximum 10% retained on a 150-m (No. 100) sieve,maximum 30 % retained on a 75-m (No. 200) sieve8. Acceptance and Re
21、jection8.1 Natural cement meets the strength requirements of thisstandard if the 7-day strength exceeds the minimum in Table 1.The cement also meets the strength requirements of thisstandard if the cement fails the 7-day strength minimum, butexceeds the 28-day strength minimum in Table 1.8.2 If the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC10C10M2014STANDARDSPECIFICATIONFORNATURALCEMENT 天然 水泥 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-463018.html