ASTM B754-2017 Standard Test Method for Measuring and Recording the Deviations from Flatness in Copper and Copper Alloy Strip《铜及铜合金带材平面偏差的测量和记录标准试验方法》.pdf
《ASTM B754-2017 Standard Test Method for Measuring and Recording the Deviations from Flatness in Copper and Copper Alloy Strip《铜及铜合金带材平面偏差的测量和记录标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM B754-2017 Standard Test Method for Measuring and Recording the Deviations from Flatness in Copper and Copper Alloy Strip《铜及铜合金带材平面偏差的测量和记录标准试验方法》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B754 10 (Reapproved 2015)1B754 17Standard Test Method forMeasuring and Recording the Deviations from Flatness inCopper and Copper Alloy Strip1This standard is issued under the fixed designation B754; the number immediately following the designation indicates the year oforiginal adoption
2、 or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1 NOTEEditorial changes were made in 1.1, 1.5 and 2.1 in May 2015.1. Scope*1.1 This test
3、 method establishes a procedure for the measurement of distortions in thin metal strip and the application of thesemeasurements to an equation that will indicate the deviation from flatness.1.2 The distortions to be measured in this test method are dish, wavy edges, buckle, longitudinal corrugation,
4、 coil set, andherringbone.1.3 This test method is not intended to include the measurement of coil set or longitudinal curl, camber, or edgewise curvature,or twist.1.4 This test method is limited to metal strip 0.003 to 0.020 in. 0.020 in. (0.08 to 0.50 mm) thick and not more than 6.0 in. (150.0mm) (
5、150.0 mm) wide.1.5 UnitsThe values stated in inch-pound units are to be regarded as standard. The values given in parentheses aremathematical conversions to SI units which are provided for information only and are not considered standard.1.6 The following safety hazard caveat pertains only to the te
6、st method(s) described in this test method. This standard does notpurport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard toestablish appropriate safety safety, health, and healthenvironmental practices and determine the a
7、pplicability of regulatorylimitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby th
8、e World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:Standard:2B846 Terminology for Copper and Copper AlloysB950 Guide for Editorial Procedures and Form of Product Specifications for Copper and Copper Alloys3. Terminology3.1 For determinati
9、on of terms relating to copper and copper alloys, refer to Terminology B846.3.2 Definitions of Terms Specific to This Standard:3.2.1 edge wave (see wavy edge), coil setna continuous pattern of waves or wrinkles along the edges of the strip, with arelatively flat center portion.as applied to strip, t
10、he natural curvature remaining in a strip after it has been unwound from a coil.4. Summary of Test Method4.1 A prepared test specimen of a specific wrought copper or copper alloy sheet or strip of a predetermined thickness is placedon a surface plate. The relative flatness of the sample is determine
11、d by measuring the length and height of the irregularity andcalculating the percent of deviation.1 This test method is under the jurisdiction of ASTM Committee B05 on Copper and Copper Alloys and is the direct responsibility of Subcommittee B05.06 on Methodsof Test.Current edition approved May 1, 20
12、15Oct. 1, 2017. Published May 2015November 2017. Originally approved in 1986. Last previous edition approved 20102015 asB754 10.B754 10(2015)1. DOI: 10.1520/B0754-10R15E01.10.1520/B0754-17.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at service
13、astm.org. For Annual Book of ASTM Standardsvolume information, refer to the standardsstandards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous ver
14、sion. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes sec
15、tion appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.2 In the case of coil set, it is measured by hanging the strip against a vertical wall or post and measuring the distance of theunrestrained han
16、ging strip end from the wall or post. That measured distance is an indication of the amount of coil set that existsin the strip as a result of processing.5. Significance and Use5.1 This test method is intended for measuring distortion in strip used for making close tolerance parts. Since distortion
17、in thisstrip would influence the shape of the part being produced and cause difficulties in feeding through close-fitting dies and othermanufacturing equipment, it is important that this material be flat.5.2 This test method provides a universal procedure for measuring the irregularities that cause
18、the deviation from flatness.5.3 This test method allows the purchaser and manufacturer to inspect strip with a standard technique to a mutually agreed uponand acceptable percentage deviation from flatness, and in the case of coil set, acceptable distance deviation from flatness.6. Apparatus6.1 Surfa
19、ce Plate, to be used as a reference flat. It must have a large enough surface area to accommodate the maximum sizetest specimen. It shall be flat within 0.0002 in. (0.005 mm) per 1 in. (25 mm).6.2 Micrometer, for measuring metal thickness. It shall be graduated in 0.0001-in. (0.0025-mm) increments.6
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB7542017STANDARDTESTMETHODFORMEASURINGANDRECORDINGTHEDEVIATIONSFROMFLATNESSINCOPPERANDCOPPERALLOYSTRIP

链接地址:http://www.mydoc123.com/p-462159.html