1、Designation: B 452 02Standard Specification forCopper-Clad Steel Wire for Electronic Application1This standard is issued under the fixed designation B 452; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specification covers bare round copper-clad st
3、eelwire for electronic application.1.2 Four classes of copper-clad steel wire are covered asfollows:1.2.1 Class 30HSNominal 30 % conductivity hard-drawn,1.2.2 Class 30ANominal 30 % conductivity annealed,1.2.3 Class 40HSNominal 40 % conductivity hard-drawn, and1.2.4 Class 40ANominal 40 % conductivity
4、 annealed.1.3 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are in SI units.2. Referenced Documents2.1 The following documents of the issue in effect on thedate of material purchase form a part of this specification to theextent referenced h
5、erein:2.2 ASTM Standards:B 193 Test Method for Resistivity of Electrical ConductorMaterials2B 258 Specification for Standard Nominal Diameters andCross-Sectional Areas of AWG Sizes of Solid Round WiresUsed as Electrical Conductors22.3 National Institute of Standards and Technology:NBS Handbook 100Co
6、pper Wire Tables33. Ordering Information3.1 Orders for material under this specification shall includethe following information:3.1.1 Quantity of each size and class,3.1.2 Wire size, diameter in inches (see 5.3 and Table 1),3.1.3 Class of wire (see 1.2 and Table 1),3.1.4 Packaging and shipping (Sect
7、ion 10),3.1.5 If inspection is required (see 6.3.3), and3.1.6 Place of inspection (see 6.1).4. Material4.1 The wire shall consist of a core of homogeneousopen-hearth, electric-furnace, or basic-oxygen steel with acontinuous outer cladding of copper thoroughly bonded to thecore throughout and shall b
8、e of such quality as to meet therequirements of this specification (Note 1).NOTE 1The copper-clad steel wire provides a high-strength conductorfor use in wire and cable where greater strength is required and a lowerconductivity can be tolerated. At high frequencies the reduced conductiv-ity is less
9、pronounced due to concentration of the current in the outerperiphery of the wire. Minimum thickness of 6 % and 10 % of the radiusfor 30 and 40 % conductivity material, respectively, has been establishedto facilitate the inspection of thickness on fine wires.5. General Requirements5.1 Tensile Strengt
10、h and ElongationThe copper-clad steelwire shall conform to the tensile strength and elongationrequirements of Table 1. For intermediate sizes not listed inTable 1, the elongation requirements of the next smaller sizeshall apply; in the case of tensile strength, the requirements ofthe next larger siz
11、e shall apply.5.2 ResistivityThe electrical resistivity at a temperature of20C shall not exceed the values prescribed in Table 2. SeeNote 2 for calculating electrical resistance.NOTE 2Relationships which may be useful in connection with thevalues of electrical resistivity prescribed in this specific
12、ation are shown inTable 3. Resistivity units are based on the International Annealed CopperStandard (IACS) adopted by IEC in 1913, which is158 Vmm2/m at 20Cfor 100 % conductivity. The value of 0.017241 Vmm2/m and the value of0.15328 Vg/m2at 20C are respectively the international equivalent ofvolume
13、and weight resistivity of annealed copper equal to 100 %conductivity. The latter term means that a copper wire 1 in. in length andweighing 1 g would have a resistance of 0.15328 V. This is equivalent toa resistivity value of 875.20V lb/mile2, which signifies the resistance ofa copper wire 1 mile in
14、length weighing 1 lb. It is also equivalent, forexample, to 1.7241 V/cm of length of a copper bar 1 cm2in cross section.A complete discussion of this subject is contained in NBS Handbook 100.The use of five significant figures in expressing resistivity does not implythe need for greater accuracy of
15、measurement than that specified in TestMethod B 193. The use of five significant figures is required for completereversible conversion from one set of resistivity units to another.5.3 Dimensions and Permissible VariationsThe wire sizes1This specification is under the jurisdiction of ASTM Committee B
16、01 onElectrical Conductors and is the direct responsibility of Subcommittee B01.06 onComposite Conductors.Current edition approved April 10, 2002. Published April 2002. Originallypublished as B 452 67. Last previous edition B 452 93(1998)e1.2Annual Book of ASTM Standards, Vol 02.03.3Available from t
17、he National Institute of Standards and Technology (NIST),Gaithersburg, MD 20899.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.shall be expressed as the diameter of the wire in decimalfractions of an inch to the nearest 0.0001 in. (
18、0.003 mm) (Note3). For diameters under 0.0100 in. (0.254 mm), the wire shallnot vary from the specified diameter by more than 60.0001 in.(0.003 mm) and for diameters of 0.0100 in. (0.254 mm) andover, the wire shall not vary from the specified diameter bymore than 61 %, expressed to the nearest 0.000
19、1 in. (0.003mm).NOTE 3The values of the wire diameters in Table 1 are given to thenearest 0.0001 in. (0.003 mm) and correspond to the standard sizes givenin Specification B 258. The use of gage numbers to specify wire sizes isnot recognized in this specification because of the possibility of confusi
20、on.An excellent discussion of wire gages and related subjects is contained inNBS Handbook 100.5.4 Adhesion and Other DefectsThe copper-clad steelwire, when tested in accordance with 7.4, shall not reveal anyseams, pits, slivers, or other imperfection of sufficient magni-tude to indicate inherent def
21、ects or imperfections. Examinationof the wire at the break with the unaided eye (normal spectaclesexcepted) shall show no separation of copper from the steel.5.5 JointsNecessary joints in the wire and rods prior tofinal drawing shall be made in accordance with good commer-cial practice. The finished
22、 wire shall contain no joints or splicesmade at finished size.5.6 FinishThe wire shall be free from copper discontinui-ties and all imperfections not consistent with good commercialpractice (see 7.5).5.7 Copper ThicknessThe minimum copper thickness dueto eccentricity shall be not less than the follo
23、wing:5.7.1 The 30 % conductivity wire shall have a minimumthickness of not less than 6 % of the wire radius.5.7.2 The 40 % conductivity wire shall have a minimumthickness of not less than 10 % of the wire radius (see 7.6 andNote 3).6. Inspection6.1 GeneralAll tests and inspections shall be made at t
24、heplace of manufacture unless otherwise agreed upon betweenthe manufacturer and the purchaser at the time of the purchase.The manufacturer shall afford the inspector representing thepurchaser all reasonable facilities to satisfy him that theTABLE 1 Tensile and Elongation RequirementsDiameter Cross-S
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB4522002STANDARDSPECIFICATIONFORCOPPERCLADSTEELWIREFORELECTRONICAPPLICATION 电子 备用 包铜钢 导线 标准规范 PDF

链接地址:http://www.mydoc123.com/p-461266.html