ASTM B354-2012 Standard Terminology Relating to Uninsulated Metallic Electrical Conductors《未绝缘金属导电体的相关标准术语》.pdf
《ASTM B354-2012 Standard Terminology Relating to Uninsulated Metallic Electrical Conductors《未绝缘金属导电体的相关标准术语》.pdf》由会员分享,可在线阅读,更多相关《ASTM B354-2012 Standard Terminology Relating to Uninsulated Metallic Electrical Conductors《未绝缘金属导电体的相关标准术语》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B354 05 B354 12Standard Terminology Relating toUninsulated Metallic Electrical Conductors1This standard is issued under the fixed designation B354; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revis
2、ion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONThese terminologies relate only to interpretations as applied to uninsulated metallic electricalconductors in specifications und
3、er the jurisdiction of ASTM Committee B01 on Electrical Conductors,and do not necessarily correspond to the definitions used in other fields.1. Scope1.1 This terminology standard defines abbreviations and terms specific to uninsulated electrical conductors. For terms relatingto superconductors, see
4、Terminology B713.2. Referenced Documents2.1 ASTM Standards:2B193 Test Method for Resistivity of Electrical Conductor MaterialsB713 Terminology Relating to Superconductors (Withdrawn 2001)33. AbbreviationsAAACall aluminum alloy conductorAACaluminum conductor.AACSRaluminum alloy conductor, steel reinf
5、orced.ACARaluminum conductor, aluminum alloy reinforced.ACSRaluminum conductor, steel reinforced.AWACSSaluminum cladconductor steel wire.supported.AZAMCaluminum coated (aluminized) steel wire.matrix composite.AWold designation for what is now termed AW2.AW2aluminum-clad steel core wire, normal stren
6、gth.AW3aluminum-clad steel core wire, high strength.AZold designation (aluminized).CCAcopper-clad aluminumCCScopper-clad steelCOMPcompact construction.EHSextra high strength.GAold designation for what is now termed GA2.GAGA2zinc coated (galvanized) steel wire, coating class A.GBGA3zinc coated (galva
7、nized) high strength steel wire, coating class B.A.GA4zinc coated (galvanized) extra high strength steel wire, coating class A.GA5zinc coated (galvanized) ultra high strength steel wire, coating class A.GBobsolete designation, class B galvanizing is no longer offered.1 This terminology is under the
8、jurisdiction of ASTM Committee B01 on Electrical Conductors and is the direct responsibility of Subcommittee B01.01 on Editorial andRecords.Current edition approved March 1, 2005Dec. 1, 2012. Published March 2005January 2013. Originally approved in 1960. Last previous edition approved in 19982005 as
9、B354 98.B354 05. DOI: 10.1520/B0354-05.10.1520/B0354-12.2 For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3
10、The last approved version of this historical standard is referenced on www.astm.org.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to ad
11、equately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshoh
12、ocken, PA 19428-2959. United States1GCold designation for what is now termed GC2.GCGC2zinc coated (galvanized) steel wire, coating class C.HSzinc coated (galvanized) high strength steel wire.high strength.IACSinternational annealed copper standard, which is 1/58 Ohm-mm2/m at 20C for 100 % conductivi
13、ty.MAold designation for what is now termed MA2.MAMA2zinc-5 % zinc-5 % aluminum-mischmetal alloy coated steel wire, coating class A.MBMA3zinc-5 % zinc-5 % aluminum-mischmetal alloy coated high strength steel wire, coating class B.A.MA4zinc-5 % aluminum-mischmetal alloy coated extra high steel wire,
14、coating class A.MA5zinc-5 % aluminum-mischmetal alloy coated ultra high steel wire, coating class A.MBobsolete designation, class B galvanizing is no longer offered.MCold designation for what is now termed MC2.MCMC2zinc-5 % zinc-5 % aluminum-mischmetal alloy coated steel wire, coating class C.MS zin
15、c-5 % aluminum-mischmetal alloy coated high strength steel wire.old designation for what is now termed MA3.MMmischmetal.NSnon-specular.SDself dampening construction.SIWsingle input wire construction.TPtwisted pair.TWtrapezoidal shaped wire.UHSultra high strength.Zn-5Al-MMzinc-5 % aluminum-mischmetal
16、 alloy coating.4. Terminology4.1 Definitions:aeolian vibrationresonant vibration of a conductor caused by the alternate shedding of wind-induced vortices from oppositesides of the conductor. (Frequency is usually less than 200 Hz and amplitude rarely exceeds one conductor diameter.)annealed wiresee
17、soft wire.area densitymass per unit area.bare conductora conductor having no nonmetallic covering.brazingthe joining of ends of two wires, rods, or groups of wires with a nonferrous filler metal at temperatures above 800F427C.breaking strengththe maximum load that a conductor attains when tested in
18、tension to rupture.bunch-stranded conductora conductor composed of wires twisted together with a given length and direction of lay in suchmanner that the respective wires at successive cross sections along the length of the conductor do not necessarily form asymmetrical geometric pattern, nor necess
19、arily occupy the same positions relative to each other.circular mil (cmil)a unit of area equal to the area of a circle one mil (0.001 in., 0.0254 mm) in diameter. The area of a circlein circular mils is equal to the square of the diameter in mils area(cmils) = diameter(mils)2, 1 cmil = 7.854 107 in.
20、2 5.067 1010 m2.clad wirewire comprised of a given metal covered with a relatively thick application of a different metal. The bonding processis normally a combination of heat and pressure and results in a metallurgical bond.coated wirewire comprised of a given metal covered with a relatively thin a
21、pplication of a different metal. The coating processis normally electroplating or dip coating.cold-drawingreducing the cross section by pulling through a die or dies, at a temperature lower than the bination stranded conductora conductor constructed with wires of different diameters with such differ
22、ences occurringeither within a single layer or from layer to pact stranded conductora unidirectional or unilay or conventional concentric conductor, constructed with a central coresurrounded by one or more layers of helically laid wires and formed into final shape by rolling, drawing, or other means
23、; andmanufactured to a specified nominal diameter, approximately 8 to 10 % below the nominal diameter of a conventionalnon-compact conductor of the same cross-sectional area.B354 122compressed stranded conductora unidirectional or unilay or conventional concentric conductor manufactured to a specifi
24、ednominal diameter 3 % less than the calculated diameter of non-compressed conductor of the same construction andcross-sectional posite conductora conductor consisting of two or more types of wire, each type of wire being plain, clad, or coated;stranded together to operate mechanically and electrica
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB3542012STANDARDTERMINOLOGYRELATINGTOUNINSULATEDMETALLICELECTRICALCONDUCTORS 绝缘 金属 导电 相关 标准 术语 PDF

链接地址:http://www.mydoc123.com/p-461016.html