ASTM B135-2010 Standard Specification for Seamless Brass Tube《无缝黄铜管的标准规格》.pdf
《ASTM B135-2010 Standard Specification for Seamless Brass Tube《无缝黄铜管的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM B135-2010 Standard Specification for Seamless Brass Tube《无缝黄铜管的标准规格》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B135 10Standard Specification forSeamless Brass Tube1This standard is issued under the fixed designation B135; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicate
2、s the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers seamless round and rectangu-lar including square copper alloy tube in straight lengths. Tenalloys are specified having the following nomin
3、al composi-tions:Copper Previously Nominal Composition, %Alloy UsedUNS Designa-No.2tionACopper Zinc Lead TinC22000 7 90.0 10.0 . .C23000 1 85.0 15.0 . .C26000 2 70.0 30.0 . .C27000 9 65.0 35.0 . .C27200 8 63.0 37.0 . .C27400 . 62.5 37.5 . .C28000 5 60.0 40.0 . .C33000 3 66.0 33.5 0.5 .C33200 4 66.0
4、32.4 1.6 .C37000 6 60.0 39.0 1.0 .C44300 . 71.5 27.5 . 1.00AAlloy Designations of Specification B135 63, which was published in the1966 Book of ASTM Standards, Part 5.1.2 This specification is the inch-pound companion toSpecification B135M; therefore, no SI equivalents are pre-sented in the specific
5、ation.1.3 WarningMercury has been designated by EPA andmany state agencies as a hazardous material that can causecentral nervous system, kidney, and liver damage. Mercury, orits vapor, may be hazardous to health and corrosive tomaterials. Caution should be taken when handling mercury andmercury-cont
6、aining products. See the applicable product Ma-terial Safety Data Sheet (MSDS) for details and EPAs website(http:/www.epa.gov/mercury/faq.htm) for additional informa-tion. Users should be aware that selling mercury or mercury-containing products, or both, in your state may be prohibited bystate law.
7、 (See 10.1.)21.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.
8、 Referenced Documents2.1 ASTM Standards:3B153 Test Method for Expansion (Pin Test) of Copper andCopper-Alloy Pipe and TubingB154 Test Method for Mercurous Nitrate Test for CopperAlloysB251 Specification for General Requirements for WroughtSeamless Copper and Copper-Alloy TubeB601 Classification for
9、Temper Designations for Copperand Copper AlloysWrought and CastE243 Practice for Electromagnetic (Eddy-Current) Exami-nation of Copper and Copper-Alloy TubesE527 Practice for Numbering Metals and Alloys in theUnified Numbering System (UNS)3. Terminology3.1 Definitions of Terms Specific to This Stand
10、ard:3.1.1 capable ofthe test need not be performed by theproducer of the material. However, if subsequent testing by thepurchaser establishes that the material does not meet theserequirements, the material shall be subject to rejection.4. Ordering Information4.1 Orders for material under the specifi
11、cation shall includethe following information:4.1.1 Alloy (Section 1),4.1.2 Temper (Section 7),4.1.3 Whether tension tests are required (for drawn tempersonly (see 8.1),4.1.4 Dimensions: diameter or distance between parallelsurfaces and wall thickness (see 11.2 and 11.3),4.1.5 Length (see 12.4),4.1.
12、6 Mercurous nitrate test, if required (Section 10),4.1.7 Total length of each size,4.1.8 Hydrostatic pressure test, when specified, and4.1.9 Pneumatic test, when specified.1This specification is under the jurisdiction ofASTM Committee B05 on Copperand Copper Alloys and is the direct responsibility o
13、f Subcommittee B05.04 on Pipeand Tube.Current edition approved Oct. 1, 2010. Published November 2010. Originallyapproved in 1940. Last previous edition approved in 2008 as B135 08a. DOI:10.1520/B0135-10.2The UNS system for copper and copper alloys (see Practice E527) is a simpleexpansion of the form
14、er standard designation system accomplished by the additionof a prefix “C” and a suffix “00.” The suffix can be used to accommodatecomposition variations of the base alloy.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For An
15、nual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5. Gener
16、al Requirements5.1 Material furnished under this specification shall con-form to the applicable requirements of the current edition ofSpecification B251.6. Chemical Composition6.1 The material shall conform to the chemical requirementsspecified in Table 1.6.2 These specification limits do not preclu
17、de the presenceof other elements. Limits for unnamed elements are to beestablished by agreement between manufacturer or supplierand purchaser.6.2.1 For copper alloys in which zinc is specified as theremainder, either copper or zinc shall be taken as the differencebetween the sum of all the elements
18、analyzed and 100 %.6.2.1.1 When all the elements in Table 1 are analyzed, theirsum shall be as shown in the following table.Copper Alloy UNS No.Copper Plus NamedElements, % minC22000 99.8C23000 99.8C26000 99.7C27000 99.7C27200 99.7C27400 99.7C28000 99.7C33000 99.6C33200 99.6C37000 99.6C44300 99.67.
19、Temper7.1 Drawn Tempers, HThe tempers of drawn tube shall bedesignated as light-drawn (H55), drawn (H58), and hard-drawn(H80) (see Table 2). Light-drawn (bending) temper is used onlywhen a tube of some stiffness but yet capable of being bent isneeded. Drawn temper is for general purposes and is most
20、commonly used where there is no specific requirement for highstrength on the one hand or for bending qualities on the other.Hard-drawn temper is used only where there is need for a tubeas strong as is commercially feasible for the sizes indicated.For any combination of diameter and wall thickness no
21、tcovered under hard-drawn temper, the values given for drawntemper shall be used. Rectangular including square tubes shallnormally be supplied only in drawn (general-purpose) temper.When there is a need for light-drawn or hard-drawn tempersthese are to be supplied as agreed upon between the manufac-
22、turer and the purchaser.7.2 Annealed Tempers, OThe tempers of annealed tubeshall be designated as light anneal (O50) and soft anneal (O60)(Table 3).NOTE 1Tube of Copper Alloy UNS No. C23000, when specified tomeet the requirements of the ASME Boiler and Pressure Vessel Code, shallhave in the annealed
23、 condition a minimum tensile strength of 40 ksi anda minimum yield strength of 12 ksi at 0.5 % extension under load, inwhich case the provisions for grain size and Rockwell hardness in 8.2 donot apply.8. Mechanical Properties8.1 Drawn TemperTube shall conform to the mechanicalproperties prescribed i
24、n Table 2. Tension tests are required fortubes with a wall thickness under 0.020 in. and for round tubeshaving an inside diameter under516 in. and for rectangularincluding square tubes having a major distance between insideparallel surfaces under316 in. The tension test for other sizes oftubes need
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB1352010STANDARDSPECIFICATIONFORSEAMLESSBRASSTUBE 无缝 铜管 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-460427.html