《ASTM A966 A966M-2008 Standard Practice for Magnetic Particle Examination of Steel Forgings Using Alternating Current《用交流电检验锻钢磁性微粒的标准实验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM A966 A966M-2008 Standard Practice for Magnetic Particle Examination of Steel Forgings Using Alternating Current《用交流电检验锻钢磁性微粒的标准实验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: A 966/A 966M 08Standard Practice forMagnetic Particle Examination of Steel Forgings UsingAlternating Current1This standard is issued under the fixed designation A 966/A 966M; the number immediately following the designation indicates the yearof original adoption or, in the case of revis
2、ion, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This practice covers a procedure for the magneticparticle examination of steel forgings using alter
3、nating currentas the power source. The procedure will produce consistentresults upon which acceptance standards can be based. Thispractice does not contain acceptance limits or recommendedquality levels.1.2 Only alternating 5060 cycle current shall be used as theelectric power source for any of the
4、magnetizing methods.1.3 When subsurface indications are sought in forgings,then dc magnetization in accordance with Practice A 275/A 275M should be used.1.4 The values stated in either inch-pound units or SI unitsare to be regarded separately as standard. Within the text, theSI units are shown in br
5、ackets. The values stated in eachsystem are not exact equivalents; therefore each system shallbe used independently of the other. Combining values from thetwo systems may result in nonconformance with the specifi-cation. Unless the order specifies the applicable “M” specifi-cation designation SI uni
6、ts, the inch-pound units shall beused.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory li
7、mitations prior to use.2. Referenced Documents2.1 ASTM Standards:2A 275/A 275M Practice for Magnetic Particle Examinationof Steel ForgingsA 508/A 508M Specification for Quenched and TemperedVacuum-Treated Carbon and Alloy Steel Forgings forPressure VesselsA 963/A 963M Specification for Deep Drawing
8、Steel(DDS), Sheet, Carbon, Cold-Rolled32.2 Other Document:Practice No. SNT-TC-1A, Supplement BMagnetic Par-ticle Method43. Terminology3.1 Definitions:3.1.1 (ac) magnetic particle method of examination, namethod for detecting discontinuities on the surface in suitablymagnetized materials, which emplo
9、ys finely divided magneticparticles that tend to congregate in regions of leakage fields.3.1.2 indication, nthe visual magnetic particle buildupresulting from leakage fields in the magnetic field.3.1.3 linear indication, nan indication in which the lengthis at least three times the width. The minimu
10、m length ofindications to be considered linear shall be116 in. 1.5 mm.3.1.4 magnetic flux, nthe product of the magnetic induc-tion and the area of a surface (or cross section) when themagnetic induction is uniformly distributed and normal to theplane of the surface.3.1.4.1 DiscussionThe concept that
11、 the magnetic field isflowing along the lines of force suggests that these lines aretherefore “flux” lines, and they are called magnetic flux.3.1.5 nonrelevant indications, nindications produced byleakage fields where the conditions causing them are present byaccident or part design, or other featur
12、es of the part having norelation to the damaging flaws being sought.3.1.5.1 DiscussionThis term signifies that such an indica-tion has no relation to the discontinuities that might constitutedefects.4. Basis of Application4.1 When in accordance with the requirements of theinquiry, contract, order, o
13、r specifications, forgings are to beexamined by the magnetic particle method using alternating1This practice is under the jurisdiction of ASTM Committee A01 on Steel,Stainless Steel and Related Alloys and is the direct responsibility of SubcommitteeA01.06 on Steel Forgings and Billets.Current editio
14、n approved March 1, 2008. Published March 2008. Originallyapproved in 1996. Last previous edition approved in 2007 as A 966/A 966M 07.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume info
15、rmation, refer to the standards Document Summary page onthe ASTM website.3Withdrawn.4Available from American Society for NonDestructive Testing, 1711 ArlingateLane, P.O. Box 28518, Columbus, OH 43228-0518.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International
16、, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.current; the manufacturer and the supplier shall be in agree-ment concerning the following:4.1.1 The locations on the forging that are to be subjected tomagnetic particle examination.4.1.2 The type, size, number, l
17、ocation, and orientation ofindications that are to be considered injurious.4.1.3 The method of application and type of magneticparticles, demagnetization requirements, and magnetic fieldstrengths.4.1.4 Acceptance standards.5. Significance and Use5.1 For ferromagnetic materials, magnetic particle exa
18、mina-tion is widely specified for the detection of surface andnear-surface flaws such as cracks, laps, seams, and linearlyoriented nonmetallic inclusions. Such examinations are in-cluded as mandatory requirements in some forging standardssuch as Specifications A 508/A 508M and A 963/A 963M.5.2 Use o
19、f alternating current as the power source formagnetic particle examination imposes a significant restrictionon the detection of subsurface indications, so that the proce-dure is essentially limited to the finding of flaws that are opento the surface. Attention therefore is drawn to the need to havet
20、he component in the finish-machined condition before con-ducting the magnetic particle examination.5.3 The presence of residual magnetic fields in a componentmay be undesirable, and an advantage of the use of an ACpower source for magnetic particle examination is that anacceptable level of demagneti
21、zation can be readily achieved.6. Personnel Requirements6.1 Personnel performing the magnetic particle examinationin this practice shall be qualified and certified in accordancewith a written procedure conforming to Practice No. SNT-TC-1A or another national standard that is acceptable to boththe pu
22、rchaser and supplier.7. Stage of Examination7.1 Unless otherwise specified by the purchaser, acceptanceexamination shall be performed on a forging in the finalmachined surface condition.8. Magnetizing Apparatus8.1 A 50 or 60 cycle alternating current shall be used. Whencurrent is passed through the
23、forging itself, the equipment shallconsist of contacting or clamping elements with sufficientsurface area and clamping pressure to allow the requiredcurrent to flow without damaging (burning) the part beingexamined.8.2 Portable electromagnetic alternating current yokes maybe used as a magnetizing ap
24、paratus.9. Magnetic Particles9.1 The inspection medium shall consist of finely dividedferromagnetic particles (which may be coated with a fluores-cent material) suspended in a suitable liquid medium or used indry powder form.10. Surface Preparation10.1 The sensitivity of the magnetic particle examin
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMA966A966M2008STANDARDPRACTICEFORMAGNETICPARTICLEEXAMINATIONOFSTEELFORGINGSUSINGALTERNATINGCURRENT

链接地址:http://www.mydoc123.com/p-460170.html