1、Designation: A 900/A 900M 01 (Reapproved 2006)Standard Test Method forLamination Factor of Amorphous Magnetic Strip1This standard is issued under the fixed designationA 900/A 900M; the number immediately following the designation indicates the yearof original adoption or, in the case of revision, th
2、e year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers measurements of laminationfactor (Note 1) of a specimen composed of strips cut from
3、amorphous magnetic material. It is suitable for the determina-tion of lamination factor for thin, flat case, metallic stripranging in width from 0.25 to 8.00 in. 6.35 mm to 203 mmand in thickness from 0.0005 to 0.005 in. 12.7 to 127 m.NOTE 1Lamination factor is also termed space factor or stackingfa
4、ctor.1.2 The values and equations stated in customary (egs-emuand inch-pound) or SI units are to be regarded separately asstandard. Within this standard, SI units are shown in brackets.The values stated in each system may not be exact equivalents;therefore, each system shall be used independently of
5、 the other.Combining values from the two systems may result in noncon-formance with this standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health
6、 practices and determine the applica-bility of regulatory limitations prior to use.2. Summary of Test Method2.1 The laminated test specimen is oriented and aligned,then subjected to pressure in a compression device. Theresulting volume is then determined from the measured speci-men height, width, an
7、d length. An equivalent solid volume iscalculated from the specimen mass and the true density of thespecimen material. The ratio of the calculated (equivalentsolid) volume to the measured volume is the lamination factor.3. Significance and Use3.1 Lamination factor S indicates the deficiency of effec
8、tivematerial volume which is due to the presence of oxides,roughness, insulating coatings, and other conditions affectingthe strip surface.3.2 This test method is used to predict the fraction of metalthat is included in the volume of the firm coil wound from thespecimen tape.4. Interferences4.1 This
9、 test method is predicated on correctly aligned teststrips and uniform compression during test. Both of theseconditions are difficult to meet whenever the test specimenshave one or more elevated ridges running lengthwise along thesurface of the strip.4.2 This test method also presupposes that the te
10、st speci-mens are free from other defects, such as camber and waviness,that may affect the lamination factor.5. Apparatus5.1 MicrometersTwo types of micrometers are includedfor use in this test method as follows:5.1.1 Motor-Operated, Deadweight (Not Spring) ActuatedMicrometer, conforming to the foll
11、owing requirements:5.1.1.1 The micrometer shall be a deadweight digital- ordial-type micrometer, having two ground and lapped circularsurfaces with a capacity of not less than 0.030 in. 0.75 mm.The movable face or presser foot shall have an area of 0.25 to0.33 in.2160 to 215 mm2 and corresponding to
12、 a diameter ofapproximately 0.56 to 0.65 in. 14.2 to 16.5 mm. The fixedface or anvil shall be of such size that the whole area of thepresser foot is in contact with the anvil in the zero position.5.1.1.2 The surface shall be parallel to within 0.000 05 in.0.0012 mm and the presser foot shall move on
13、 an axisperpendicular to the anvil.5.1.1.3 The presser foot shall exert a steady pressure on thespecimen of 7.0 to 8.0 psi 48 to 55 kPa.5.1.1.4 A digital readout is preferred. If an analog gauge isused, the dial shall be at least 2 in. 51 mm in diameter. It shallbe continuously graduated to read dir
14、ectly to 0.0001 in.0.0025 mm and shall be required with a telltale hand, ifnecessary, recording the number of complete revolutions of thelarge hand.5.1.1.5 The micrometer shall be capable of repeating itsreadings to 0.000 05 in. 0.0012 mm at zero setting or on asteel gauge block.1This test method is
15、 under the jurisdiction of ASTM Committee A06 onMagnetic Properties and is the direct responsibility of SubcommitteeA06.01 on TestMethods.Current edition approved May 1, 2006. Published May 2006. Originallyapproved in 1991. Last previous edition approved in 2001 as A 900/A 900M 01.1Copyright ASTM In
16、ternational, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.1.1.6 The deviations for the parts of the scale correspond-ing to the specimen thickness measured shall be applied ascorrections to the thickness reading.5.1.1.7 The frame of the micrometer shall be of
17、 such rigiditythat a load of 3 lb 1.5 kg applied to the dial housing, out ofcontact with either the weight or the presser foot spindle, willproduce a deflection of the frame not greater than 0.0001 in.0.0025 mm, as indicated on the micrometer dial.5.2 Manually Operated Deadweight (Not Spring) Actuat
18、edDial-Type Micrometer, conforming to the general requirementsof 5.1.1 to 5.1.1.7.5.3 Holding Fixture, to facilitate the aligning of the teststrips and to hold them aligned during the test, is included foruse on this test method. A sample design is given in AppendixX1.6. Sampling and Test Specimens6
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMA900A900M20012006STANDARDTESTMETHODFORLAMINATIONFACTOROFAMORPHOUSMAGNETICSTRIP 无定形 磁条 分层 系数 标准 试验

链接地址:http://www.mydoc123.com/p-459898.html