ASTM A804 A804M-2004(2009)e1 Standard Test Methods for Alternating-Current Magnetic Properties of Materials at Power Frequencies Using Sheet-Type Test Specimens《在电力频率下用薄钢板型试样对材料交流磁.pdf
《ASTM A804 A804M-2004(2009)e1 Standard Test Methods for Alternating-Current Magnetic Properties of Materials at Power Frequencies Using Sheet-Type Test Specimens《在电力频率下用薄钢板型试样对材料交流磁.pdf》由会员分享,可在线阅读,更多相关《ASTM A804 A804M-2004(2009)e1 Standard Test Methods for Alternating-Current Magnetic Properties of Materials at Power Frequencies Using Sheet-Type Test Specimens《在电力频率下用薄钢板型试样对材料交流磁.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: A804/A804M 04 (Reapproved 2009)1Standard Test Methods forAlternating-Current Magnetic Properties of Materials atPower Frequencies Using Sheet-Type Test Specimens1This standard is issued under the fixed designation A804/A804M; the number immediately following the designation indicates th
2、e yearof original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEEditorial changes were made throughout in May 2009.1. Sco
3、pe1.1 These test methods cover the determination of specificcore loss and peak permeability of single layers of sheet-typespecimens tested with normal excitation at a frequency of 50 or60 Hz.NOTE 1These test methods have been applied only at the commercialpower frequencies, 50 and 60 Hz, but with pr
4、oper instrumentation andapplication of the principles of testing and calibration embodied in the testmethods, they are believed to be adaptable to testing at frequenciesranging from 25 to 400 Hz.1.2 These test methods use calibration procedures thatprovide correlation with the 25-cm 250-mm Epstein t
5、est.1.3 The range of test magnetic flux densities is governed bythe properties of the test specimen and by the availableinstruments and other equipment components. Normally, non-oriented electrical steels can be tested over a range from 8 to 16kG 0.8 to 1.6 T for core loss. For oriented electrical s
6、teels, thenormal range extends to 18 kG 1.8 T. Maximum magneticflux densities in peak permeability testing are limited princi-pally by heating of the magnetizing winding and tests arelimited normally to a maximum ac magnetic field strength ofabout 150 Oe 12 000 A/m.1.4 These test methods cover two a
7、lternative procedures asfollows:Test Method 1Sections 6-12Test Method 2Sections 13-191.4.1 Test Method 1 uses a test fixture having (1) twowindings that encircle the test specimen, and (2) a ferromag-netic yoke structure that serves as the flux return path and haslow core loss and low magnetic reluc
8、tance.1.4.2 Test Method 2 uses a test fixture having (1) twowindings that encircle the test specimen, (2) a third windinglocated inside the other two windings and immediately adja-cent to one surface of the test specimen, and (3) a ferromag-netic yoke structure which serves as the flux-return path a
9、ndhas low magnetic reluctance.1.5 The values and equations stated in customary (cgs-emuand inch-pound) units or SI units are to be regarded separatelyas standard. Within this standard, SI units are shown inbrackets except for the sections concerning calculations wherethere are separate sections for
10、the respective unit systems. Thevalues stated in each system may not be exact equivalents;therefore, each system shall be used independently of the other.Combining values from the two systems may result in noncon-formance with this standard.1.6 This standard does not purport to address all of thesaf
11、ety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2A34/A34M Practice for Sampling
12、and Procurement Testingof Magnetic MaterialsA340 Terminology of Symbols and Definitions Relating toMagnetic TestingA343/A343M Test Method for Alternating-Current Mag-netic Properties of Materials at Power Frequencies UsingWattmeter-Ammeter-Voltmeter Method and 25-cm EpsteinTest FrameA677 Specificati
13、on for Nonoriented Electrical Steel FullyProcessed TypesA683 Specification for Nonoriented Electrical Steel, Semi-processed TypesA876 Specification for Flat-Rolled, Grain-Oriented,Silicon-Iron, Electrical Steel, Fully Processed Types3. Terminology3.1 Definitions:1These test methods are under the jur
14、isdiction of ASTM Committee A06 onMagnetic Properties and are the direct responsibility of Subcommittee A06.01 onTest Methods.Current edition approved May 1, 2009. Published January 2010. Originallyapproved in 1982. Last previous edition approved in 2004 as A804/A804M04.DOI: 10.1520/A0804_A0804M-04R
15、09E01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, P
16、O Box C700, West Conshohocken, PA 19428-2959, United States.3.1.1 GeneralThe definitions of terms, symbols, and con-version factors relating to magnetic testing found in Terminol-ogy A340 are used in these test methods.3.2 Definitions of Terms Specific to This Standard:3.2.1 sheet specimena rectangu
17、lar specimen comprised ofa single piece of material or paralleled multiple strips ofmaterial arranged in a single layer.4. Significance and Use4.1 Materials EvaluationThese test methods were devel-oped to supplement the testing of Epstein specimens forapplications involving the use of flat, sheared
18、laminationswhere the testing of Epstein specimens in either the as-shearedor stress-relief-annealed condition fails to provide the mostsatisfactory method of predicting magnetic performance in theapplication.As a principal example, the test methods have beenfound particularly applicable to the contr
19、ol and evaluation ofthe magnetic properties of thermally flattened, grain-orientedelectrical steel (Condition F5, Specification A876) used aslamination stock for cores of power transformers. Inasmuch asthe test methods can only be reliably used to determineunidirectional magnetic properties, the tes
20、t methods havelimited applicability to the testing of fully processed nonori-ented electrical steels as normally practiced (SpecificationA677).4.2 Specification AcceptanceThe reproducibility of testresults and the accuracy relative to the 25-cm 250-mmEpstein method of test are considered such as to
21、render the testmethods suitable for materials specification testing.4.3 Interpretation of Test ResultsBecause of specimensize, considerable variation in magnetic properties may bepresent within a single specimen or between specimens thatmay be combined for testing purposes. Also, variations mayexist
22、 in test values that are combined to represent a test lot ofmaterial. Test results reported will therefore, in general, repre-sent averages of magnetic quality and in certain applications,particularly those involving narrow widths of laminations,deviations in magnetic performance from those expected
23、 fromreported data may occur at times. Additionally, application oftest data to the design or evaluation of a particular magneticdevice must recognize the influence of magnetic circuitry uponperformance and the possible deterioration in magnetic prop-erties arising from construction of the device.4.
24、4 Recommended Standard TestsThese test methodshave been principally applied to the magnetic testing ofthermally flattened, grain-oriented electrical steels at 50 and 60Hz. Specific core loss at 15 or 17 kG 1.5 or 1.7 T and peakpermeability (if required) at 10 Oe 796 A/m are the recom-mended paramete
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMA804A804M20042009E1STANDARDTESTMETHODSFORALTERNATINGCURRENTMAGNETICPROPERTIESOFMATERIALSATPOWERFREQUENCIESUSINGSHEETTYPETESTSPECIMENS

链接地址:http://www.mydoc123.com/p-459618.html