ASTM A795 A795M-2013 Standard Specification for Black and Hot-Dipped Zinc-Coated (Galvanized) Welded and Seamless Steel Pipe for Fire Protection Use《消防用黑色和热浸镀锌(电镀)焊接钢管及无缝钢管标准规格》.pdf
《ASTM A795 A795M-2013 Standard Specification for Black and Hot-Dipped Zinc-Coated (Galvanized) Welded and Seamless Steel Pipe for Fire Protection Use《消防用黑色和热浸镀锌(电镀)焊接钢管及无缝钢管标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM A795 A795M-2013 Standard Specification for Black and Hot-Dipped Zinc-Coated (Galvanized) Welded and Seamless Steel Pipe for Fire Protection Use《消防用黑色和热浸镀锌(电镀)焊接钢管及无缝钢管标准规格》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: A795/A795M 08 (Reapproved 2012)A795/A795M 13Standard Specification forBlack and Hot-Dipped Zinc-Coated (Galvanized) Welded andSeamless Steel Pipe for Fire Protection Use1This standard is issued under the fixed designation A795/A795M; the number immediately following the designation indi
2、cates the yearof original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers black and hot-d
3、ipped galvanized welded and seamless steel pipe in NPS 1/2 to NPS 10, inclusiveDN 15 to DN 250, inclusive (Note 1), with wall thicknesses as given in Table 1 and Table 2. Pipe having other wall thicknessesmay be furnished provided such pipe complies with all other requirements of this specification
4、and the outside diameter is as givenin Table 2. Pipe ordered under this specification is intended for use in fire protection systems. The pipe may be bent, but it is notintended for bending made at ambient temperature wherein the inside diameter of the bend is less than twelve times the outsidediame
5、ter of the pipe being bent (Note 2).NOTE 1The dimensionless designators NPS (nominal pipe size) and DN (nominal diameter) have been substituted in this standard for such traditionalterms as “nominal diameter,” “size,” and “nominal size.”NOTE 2Successful bending of pipe is a function of equipment and
6、 technique as well as pipe properties.1.2 This pipe is suitable for joining by the following methods:1.2.1 Light-Weight Fire Protection Pipe Rolled groove, welding, and fittings for plain end pipe. See Table 1 for dimensions.1.2.2 Standard-Weight Fire Protection PipeCut or rolled groove, threading,
7、welding, and fittings for plain end pipe. See Table2 for dimensions.1.2.3 For pipe having dimensions other than those of Table 1 and Table 2, the joining method must be compatible with the pipedimensions. A complete listing of standard light weight dimensions appears in ASME B36.10 and B36.19.1.3 Th
8、e following safety hazards caveat pertains only to the test method portion, Sections 8, 9, and 10, of this specification:Thisstandard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the userof this standard to establish appropriate
9、 safety and health practices and determine the applicability of regulatory limitations priorto use.1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. Within the text, the SI unitsare shown in brackets. The values stated in each system may not be e
10、xact equivalents; therefore, each system shall be usedindependently of the other. Combining values from the two systems may result in non-conformance with the standard.2. Referenced Documents2.1 ASTM Standards:2A90/A90M Test Method for Weight Mass of Coating on Iron and Steel Articles with Zinc or Z
11、inc-Alloy CoatingsA700 Practices for Packaging, Marking, and Loading Methods for Steel Products for ShipmentA751 Test Methods, Practices, and Terminology for Chemical Analysis of Steel ProductsA865 Specification forThreaded Couplings, Steel, Black or Zinc-Coated (Galvanized)Welded or Seamless, for U
12、se in Steel PipeJointsB6 Specification for ZincE213 Practice for Ultrasonic Testing of Metal Pipe and TubingE309 Practice for Eddy-Current Examination of Steel Tubular Products Using Magnetic SaturationE570 Practice for Flux Leakage Examination of Ferromagnetic Steel Tubular Products1 This specifica
13、tion is under the jurisdiction ofASTM Committee A01 on Steel, Stainless Steel and RelatedAlloys and is the direct responsibility of Subcommittee A01.09on Carbon Steel Tubular Products.Current edition approved Sept. 1, 2012May 1, 2013. Published November 2012June 2013. Originally approved in 1982. La
14、st previous edition approved in 20082012 asA795/A795M08. 08 (2012). DOI: 10.1520/A0795_A0795M-08R12.10.1520/A0795_A0795M-13.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, re
15、fer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all c
16、hanges accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100
17、Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States12.2 ASME Standards:B1.20.1 Pipe Threads, General Purpose, Inch3B36.10 Welded and Seamless Wrought Steel Pipe3B36.19 Stainless Steel Pipe32.3 Federal Standard:Fed. Std. No. 123 Marking for Shipments (Civil Agencies)42.4 M
18、ilitary Standards:MIL-STD-129 Marking for Shipment and Storage4MIL-STD-163 Steel Mill Products, Preparation for Shipment and Storage43. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 defectan imperfection of sufficient size or magnitude to be cause for rejection.3 Available from
19、 American Society of Mechanical Engineers (ASME), ASME International Headquarters, Three Park Ave., New York, NY 10016-5990, http:/www.asme.org.4 Available from Standardization Documents Order Desk, Bldg. 4 Section D, 700 Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.TABLE 1 Dimensions, Wei
20、ghts, and Test Pressure For Light-Weight Fire Protection PipeSchedule 10ANPSDesignatorDNDesignatorOutside Diameter Nominal Wall Thickness Weight Plain EndTest PressureFurnace-WeldedSeamless andElectric-Resistance-Weldedin. mm in. mm lb/ft kg/m psi kPa psi kPa34 20 1.050 26.7 0.083 2.11 0.86 1.28 500
21、 3400 700 48001 25 1.315 33.4 0.109 2.77 1.41 2.09 500 3400 700 4800114 32 1.660 42.2 0.109 2.77 1.81 2.69 500 3400 1000 6900112 40 1.900 48.3 0.109 2.77 2.09 3.11 500 3400 1000 69002 50 2.375 60.3 0.109 2.77 2.64 3.93 500 3400 1000 6900212 65 2.875 73.0 0.120 3.05 3.53 5.26 500 3400 1000 69003 80 3
22、.500 88.9 0.120 3.05 4.34 6.46 500 3400 1000 6900312 90 4.000 101.6 0.120 3.05 4.98 7.41 500 3400 1200 83004 100 4.500 114.3 0.120 3.05 5.62 8.37 500 3400 1200 83005 125 5.563 141.3 0.134 3.40 7.78 11.58 B B 1200 83006 150 6.625 168.3 0.134 3.40 9.30 13.85 B B 1000 69008 200 8.625 219.1 0.188C 4.78
23、16.96 25.26 B B 800 550010 250 10.750 273.1 0.188C 4.78 21.23 31.62 B B 700 4800A Schedule 10 corresponds to Schedule 10S as listed in ANSI B36.19 for NPS 34 through 6 DN 20 through 150 only.B Furnace-welded pipe is not made in sizes larger than NPS 4 DN 100.C Not Schedule 10.TABLE 2 Dimensions, Wei
24、ghts, Test Pressures For Standard-Weight Fire Protection PipeSchedule 30 and Schedule 40NPSDesignatorDNDesignatorSpecified OutsideDiameterNominal WallThicknessA Weight Plain EndWeight Threadedand CoupledBTest PressureFurnace-WeldedSeamless andElectric-Resistance-Weldedin. mm in. mm lb/ft kg/m lb/ft
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMA795A795M2013STANDARDSPECIFICATIONFORBLACKANDHOTDIPPEDZINCCOATEDGALVANIZEDWELDEDANDSEAMLESSSTEELPIPEFORFIREPROTECTIONUSE

链接地址:http://www.mydoc123.com/p-459584.html