ASTM A630-2016a Standard Test Methods for Determination of Tin Coating Weights for Electrolytic Tin Plate《测定热浸电解镀锡板镀锡层重量的标准试验方法》.pdf
《ASTM A630-2016a Standard Test Methods for Determination of Tin Coating Weights for Electrolytic Tin Plate《测定热浸电解镀锡板镀锡层重量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM A630-2016a Standard Test Methods for Determination of Tin Coating Weights for Electrolytic Tin Plate《测定热浸电解镀锡板镀锡层重量的标准试验方法》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: A630 16A630 16aStandard Test Methods forDetermination of Tin Coating Weights for Electrolytic TinPlate1This standard is issued under the fixed designation A630; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year
2、of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.INTRODUCTIONFour test methods for determi
3、nation of tin coating weights are described. These are typical methodsand represent those most commonly used in the tin plate industry. Publication of these test methodsis not intended to preclude the use of any other methods such as X-ray fluorescence measurementsystems for control purposes by the
4、consumer or supplier. However, in case of dispute, the refereemethod is to be used to determine conformance to Specification A624/A624M and SpecificationA626/A626M.Sampling procedures for tin coating-weight testing and applicable standards for the specific classdesignation are outlined in Specificat
5、ion A624/A624M and Specification A626/A626M.1. Scope1.1 These test methods include four methods for the determination of tin coating weights for electrolytic tin plate as follows:Test Method SectionsABendix Test Method 3 to 9BConstant-Current, Electrolytic Test Method (Referee Method) 10 to 18BConst
6、ant-Current, Electrolytic Test Method (Referee Method) 10 to 17CSellars Test Method 19 to 28CSellars Test Method 18 to 27DTitration Test Method 29 to 37DTitration Test Method 28 to 361.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathema
7、ticalconversions to SI units that are provided for information only and are not considered standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and heal
8、th practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2A624/A624M Specification for Tin Mill Products, Electrolytic Tin Plate, Single ReducedA626/A626M Specification for Tin Mill Products, Electrolytic Tin Plate, Double ReducedD1
9、125 Test Methods for Electrical Conductivity and Resistivity of WaterMETHOD ADETERMINATION OF THE TIN COATING WEIGHTS BY THE BENDIX TEST METHOD3. Scope3.1 This test method covers the determination of tin coating weights on steel plate.1 These test methods are under the jurisdiction of ASTM Committee
10、 A01 on Steel, Stainless Steel and Related Alloys and are the direct responsibility of SubcommitteeA01.20 on Tin Mill Products.Current edition approved May 1, 2016Dec. 1, 2016. Published September 2016December 2016. Originally approved in 1968. Last previous edition approved in 20142016as A630 - 03A
11、630 - 16.(2014). DOI: 10.1520/A0630-16.10.1520/A0630-16A.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This
12、 document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior edition
13、s as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. U
14、nited States14. Summary of Test Method4.1 The procedure involves dissolution of tin from a tin plate anode in a dilute hydrochloric acid solution containing a measuredexcess of standard potassium iodate-potassium iodide solution. Excess iodine from the iodate-iodide solution is back titrated withsta
15、ndard sodium thiosulfate using a starch indicator.5. Apparatus35.1 The detinning cell consists essentially of two cathodes of carbon rod, the sample that serves as an anode, and a beaker ofdilute hydrochloric acid electrolyte. The carbon rods (6 by 0.25 in. or 152 by 6.35 mm, encased in porous porce
16、lain thimbles) aresuspended from a suitable frame about 1 in. (25 mm) apart. A small glass-enclosed magnet is attached to the frame in such amanner that it will hold the sample suspended midway between the two cathodes. A movable platform permits the beaker ofelectrolyte to be brought up around the
17、assembly so that the sample will be completely immersed.5.2 A source of direct current that can be regulated to supply up to 3 A at 3 to 5 V through the deplater is required.5.3 Although regular laboratory glassware can be used, it is advisable to use automatic dispensing pipets or burets, amotor-dr
18、iven stirrer for titrations, and a timing switch when large numbers of determinations are to be made.5.4 PrecautionsThe apparatus must be kept in continuous operation to prevent iron in the solution adhering to the porous cellsfrom oxidizing and subsequently liberating iodine from the potassium ioda
19、te-potassium iodide solution. If the instrument has beenidle for some time, it is necessary to remove the ferric iron by running a disk of tinplate through the regular procedure before testsamples are run.6. Reagents6.1 Purity of ReagentsReagent grade chemicals shall be used in all tests. Unless oth
20、erwise indicated, it is intended that allreagents shall conform to the specifications of the Committee on Analytical Reagents of the American Chemical Society wheresuch specifications are available.4 Other grades may be used, provided it is first ascertained that the reagent is of sufficiently highp
21、urity to permit its use without lessening the accuracy of the determination.6.2 WaterDeionized or distilled water having a volume resistivity greater than 1 Mcm at 25C as determined by NonrefereeMethod of Test Methods D1125.6.3 Hydrochloric Acid (1.7 to 2.0 N)Add 1 part of concentrated hydrochloric
22、acid (HCl, sp gr 1.19, 36.5 to 38.0%) to 5 partsof water and mix well.6.4 Potassium Iodate-Potassium Iodide, Standard Solution (0.0975 N)Dissolve 3.48 g of KIO3, 21.74 g of KI, and 1.21 g ofNaOH in 1 L of distilled water. Standardize as follows: Transfer 0.2700 g of National Bureau of Standards tin
23、to a 500-mLErlenmeyer flask. Add 200 mL of HCl (1+1). Connect the flask to a carbon dioxide (CO2) system and displace the air in the flaskwith CO2. While continuing the flow of CO2, heat the flask but do not boil violently. After the tin has dissolved add 0.5 g ofantimony and 2 g of high-purity alum
24、inum. Heat until the aluminum is completely dissolved and digest for an additional 10 min.Cool the flask to room temperature in running water while maintaining an atmosphere of CO2. Disconnect from the CO2 systemand titrate with the KIO3-KI solution using starch as an indicator. Calculate the tin ti
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMA6302016ASTANDARDTESTMETHODSFORDETERMINATIONOFTINCOATINGWEIGHTSFORELECTROLYTICTINPLATE 测定 电解 镀锡 重量

链接地址:http://www.mydoc123.com/p-458996.html