ASTM A561-2008 Standard Practice for Macroetch Testing of Tool Steel Bars《工具钢棒的宏观刻蚀试验标准实施规程》.pdf
《ASTM A561-2008 Standard Practice for Macroetch Testing of Tool Steel Bars《工具钢棒的宏观刻蚀试验标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM A561-2008 Standard Practice for Macroetch Testing of Tool Steel Bars《工具钢棒的宏观刻蚀试验标准实施规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: A 561 08Standard Practice forMacroetch Testing of Tool Steel Bars1This standard is issued under the fixed designation A 561; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parent
2、heses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This practice for macroetch testing has been found to bea useful and r
3、eliable method for evaluating the quality of toolsteel bars. It is used as a quality control and inspection test toreveal by deep acid etching the macrostructure in specimenscut from bars and to show the presence of such conditions aspipe, cracks, porosity, segregation, or foreign material. Theetche
4、d surface is generally examined visually, but magnifica-tion up to about 103 is occasionally employed.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not con
5、sidered standard.2. Referenced Documents2.1 ASTM Adjuncts:Twelve Photomacrographs23. Apparatus3.1 Etching ContainersMacroetching may be performedin a vessel of borosilicate glass, porcelain, corrosion-resistantmetals, or some other acid-resisting material.4. Reagent4.1 Etching ReagentA solution of e
6、qual volumes of con-centrated hydrochloric acid (HCl, sp gr 1.19) and water iscommonly used for macroetching tool steels. This solutionmust be used under a ventilating hood because HCl is volatileand the fumes are corrosive and irritating, although nontoxic.The solution may be reused within limits.
7、With use, theconcentration of dissolved iron and other metals increases andthe acidity of the solution decreases retarding the etchingaction. Spent solution shall be replaced with fresh solution, notreplenished with concentrated acid.5. Sampling5.1 The selection of specimens for macroetch testing mu
8、stbe done with care for interpretations to be of value.5.1.1 Specimens are usually cut from hot-rolled annealedbars, but may be cut from machined or ground bars if the barsare to be finish machined or ground.5.1.2 The specimen should be located at a sufficient distancefrom the end of the bar to avoi
9、d end effects.5.1.3 For ease in handling, use specimens14 to12 in. (6.35to 12.7 mm) thick.5.1.4 Cut specimens to expose a transverse section of thebar; however, the test is occasionally performed on a longitu-dinal section.5.1.5 Specimens may be taken from one or both ends of abar. Each bar may be s
10、ampled, or a few typical specimens maybe tested as representative of a large number of bars.6. Specimen Preparation6.1 In all cutting and grinding operations on the specimen,care must be excercised to avoid heating the surface to anexcessively high temperature. Specimens are cut from bars bysawing,
11、machining, abrasive wheel cutting, or other means.Cutting should be controlled to prevent smearing the cut faceand masking the structure.6.1.1 The “as-cut” surface of a specimen may be sufficientlysmooth to reveal the defects for which the examination isconducted. No additional surface preparation m
12、ay then benecessary.6.1.2 Additional surface preparation may be required toremove cutting marks and to allow details to be revealed byetching. In such circumstances, machining, grinding, or pol-ishing may be necessary. Generally, the degree of surface1This practice is under the jurisdiction of ASTM
13、Committee A01 on Steel,Stainless Steel and Related Alloys and is the direct responsibility of SubcommitteeA01.29 on Tool Steels.Current edition approved Oct. 1, 2008. Published October 2008. Originallyapproved in 1966. Last previous edition approved in 2004 as A 561 71 (2004).2Available from ASTM In
14、ternational Headquarters. Order Adjunct No.ADJA0561. Original adjunct produced in 1984.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.smoothness required is greater the finer the detail that must beresolved. When the action of the e
15、tchant is drastic, a coarsersurface finish may be used.6.1.3 The surface must be free of adhering grease and oil.There should be no scale or oxide on the surface which will beexamined after etching.7. Procedure7.1 Temperature for MacroetchingEtching characteristicsare influenced markedly by the temp
16、erature of the etchant.Thus, the reagent temperature should be controlled for macro-etching if comparative results are desired. Tool steels aregenerally macroetched at about 160F (71C). At this tempera-ture, the etching reaction is vigorous and solution lossesthrough evaporation are not excessive. T
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMA5612008STANDARDPRACTICEFORMACROETCHTESTINGOFTOOLSTEELBARS 工具钢 宏观 刻蚀 试验 标准 实施 规程 PDF

链接地址:http://www.mydoc123.com/p-458768.html