ASTM A270-2003a Standard Specification for Seamless and Welded Austenitic Stainless Steel Sanitary Tubing《卫生设施用无缝和焊接奥氏体不锈钢管的标准规范》.pdf
《ASTM A270-2003a Standard Specification for Seamless and Welded Austenitic Stainless Steel Sanitary Tubing《卫生设施用无缝和焊接奥氏体不锈钢管的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM A270-2003a Standard Specification for Seamless and Welded Austenitic Stainless Steel Sanitary Tubing《卫生设施用无缝和焊接奥氏体不锈钢管的标准规范》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: A 270 03aStandard Specification forSeamless and Welded Austenitic and Ferritic/AusteniticStainless Steel Sanitary Tubing1This standard is issued under the fixed designation A 270; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This specific
3、ation covers grades of seamless, welded,and heavily cold worked welded austenitic and ferritic/austenitic stainless steel sanitary tubing intended for use in thedairy and food industry and having special surface finishes.Pharmaceutical quality may be requested, as a supplementaryrequirement.1.2 This
4、 specification covers tubes in sizes up to andincluding 12 in. (304.8 mm) in outside diameter.1.3 The values stated in inch-pound units are to be regardedas the standard.1.4 Optional supplementary requirements are provided, andwhen one or more of these are desired, each shall be so statedin the orde
5、r.2. Referenced Documents2.1 ASTM Standards:2A 262 Practices for Detecting Susceptibility to Intergranu-lar Attack in Austenitic Stainless SteelsA 480/A 480M Specification for General Requirements forFlat-Rolled Stainless and Heat-Resisting Steel Plate,Sheet, and StripA 923 Test Methods for Detectin
6、g Detrimental IntermetallicPhase in Wrought Duplex Austenitic/Ferritic StainlessSteelsA 967 Specification for Chemical Passivation Treatmentsfor Stainless Steel PartsA 1016/A 1016M Specification for General Requirementsfor Ferritic Alloy Steel, Austenitic Alloy Steel, and Stain-less Steel TubesE 527
7、 Practice for Numbering Metals and Alloys (UNS)2.2 ASME Standard:B46.1 Surface Texture (Surface Roughness, Waviness, andLay)32.3 ASME Boiler and Pressure Vessel Code:Section VIII Pressure Vessels32.4 Other Standard:SAE J1086 Practice for Numbering Metals and Alloys(UNS)43. Terminology3.1 Definition:
8、3.1.1 roughness average, Ra, narithmetic average surfaceroughness normally reported in microinches or microns; ameasurement of surface roughness usually performed by mov-ing a stylus in a straight line along the surface, although othermethods may be used.4. Ordering Information4.1 It is the responsi
9、bility of the purchaser to specify allrequirements that are necessary for material ordered under thisspecification. Such requirements may include, but are notlimited to, the following:4.1.1 Quantity (feet, metres, or number of lengths),4.1.2 Name of material (austenitic steel tube),4.1.3 Process sea
10、mless (SML), welded (WLD), or heavilycold worked (HCW),4.1.4 Size (outside diameter and average wall thickness),4.1.5 Length (specific or random),4.1.6 Surface finish (Section 13),4.1.7 Optional requirements (product analysis, see Section9; hydrostatic or nondestructive electric test, see Section11)
11、.4.1.8 Test report required (Certification Section of Specifi-cation A 1016/A 1016M),4.1.9 Specification designation,4.1.10 Special requirements, and1This specification is under the jurisdiction of ASTM Committee A01 on Steel,Stainless Steel and Related Alloys, and is the direct responsibility of Su
12、bcommitteeA01.10 on Stainless and Alloy Steel Tubular Products.Current edition approved Dec. 1, 2003. Published January 2004. Originallyapproved in 1944. Last previous edition approved in 2003 as A 27003.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Se
13、rvice at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from ASME International, Three Park Avenue, New York, NY100165990.4Available from Society of Automotive Engineers (SAE), 400 CommonwealthDr., Warr
14、endale, PA 15096-0001.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.2 Any supplementary requirements.5. General Requirements5.1 Material furnished under this speci
15、fication shall con-form to the applicable requirements of the current edition ofSpecification A 1016/A 1016M, unless otherwise providedherein.6. Manufacture6.1 The tubes shall be manufactured by one of the followingprocesses:6.1.1 Seamless (SML) tubes shall be made by a process thatdoes not involve
16、welding at any stage.6.1.2 Welded (WLD) tubes shall be made using an auto-mated welding process with no addition of filler metal duringthe welding process.6.1.3 Heavily cold worked (HCW) tubes shall be made byapplying cold working of not less than 35 % reduction ofthickness of both wall and weld to
17、a welded tube prior to thefinal anneal. No filler shall be used in making the weld. Priorto cold working, the weld shall be 100 % radiographicallyinspected in accordance with the requirements ofASME Boilerand Pressure Vessel Code Section VIII, Division 1, latestrevision, Paragraph UW 51.6.2 At the m
18、anufacturers option, tubing may be furnishedeither hot finished or cold finished.7. Heat Treatment7.1 All material shall be furnished in the heat-treatedcondition. The heat treatment procedure, except for S31803,S32003, S32205, S32750, N08926 and N08367, shall consistof heating the material to a min
19、imum temperature of 1900F(1040C) and quenching in water or rapid cooling by othermeans.7.2 N08926 shall be heat-treated to a minimum temperatureof 2010F 1100C followed by quenching in water or rapidlycooling by other means. UNS N08367 should be solutionannealed from 2025F 1107C minimum followed by r
20、apidquenching.7.3 S31803 and S32205 shall be heat-treated in a tempera-ture range of 1870F 1020C to 2010F 1100C followedby quenching in water or rapidly cooling by other means.7.4 S32750 shall be heat-treated in a temperature range of1880F 1025C to 2060F 1125C followed by quenchingin water or rapidl
21、y cooling by other means.7.5 S32003 shall be heat-treated in a temperature range of1850F (1010C) to 2010F (1100C).8. Chemical Composition8.1 An analysis of either one length of flat-rolled stock orone tube shall be made for each heat. The chemical composi-tion thus determined shall conform to the re
22、quirements given inTable 1.9. Product Analysis9.1 When requested by the purchaser, product analysistolerance in Specification A 480/A 480M shall apply. Theproduct analysis tolerance is not applicable to the carboncontent for material with a specified maximum carbon of0.04 % or less.9.2 If the origin
23、al test for product analysis fails, retests oftwo additional lengths of flat-rolled stock or tubes shall bemade. Both retests for the elements in question shall meet therequirements of the specification; otherwise all remainingmaterial in the heat or lot (Note 1) shall be rejected or, at theoption o
24、f the producer, each length of flat-rolled stock or tubemay be individually tested for acceptance. Lengths of flatrolled stock or tubes that do not meet the requirements of thespecification shall be rejected.10. Mechanical Tests Required10.1 Reverse Flattening TestFor welded tubes, one re-verse flat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMA2702003ASTANDARDSPECIFICATIONFORSEAMLESSANDWELDEDAUSTENITICSTAINLESSSTEELSANITARYTUBING 卫生 施用 无缝

链接地址:http://www.mydoc123.com/p-457878.html