ASTM A1073 A1073M-2012 Standard Practice for Using Hand Micrometers to Measure the Thickness of Nonmetallic and Metallic-Coated Steel Sheet《用手动千分尺测定非金属物质和金属物质镀层钢板的标准实施规程》.pdf
《ASTM A1073 A1073M-2012 Standard Practice for Using Hand Micrometers to Measure the Thickness of Nonmetallic and Metallic-Coated Steel Sheet《用手动千分尺测定非金属物质和金属物质镀层钢板的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM A1073 A1073M-2012 Standard Practice for Using Hand Micrometers to Measure the Thickness of Nonmetallic and Metallic-Coated Steel Sheet《用手动千分尺测定非金属物质和金属物质镀层钢板的标准实施规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: A1073/A1073M 12Standard Practice forUsing Hand Micrometers to Measure the Thickness ofNonmetallic and Metallic-Coated Steel Sheet1This standard is issued under the fixed designation A1073/A1073M; the number immediately following the designation indicates theyear of original adoption or,
2、 in the case of revision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice defines procedures for measuring thethickness of nonmetallic and m
3、etallic-coated steel sheet.Thickness is a significant quality characteristic of steel sheetproducts. The ability to accurately measure thickness usinghand micrometers is critical in determining product confor-mance to specifications. The methods described are designedand intended for use in both lab
4、oratory and plant situations andtheir environments.1.2 The flat steel product shall conform to all the require-ments of the appropriate specifications as follows: Specifica-tions A924/A924M and A917.1.3 Quantitative limits are not addressed and are establishedin the general requirements, or individu
5、al product specifica-tions, or both; or when applicable, as agreed to betweensupplier and user.1.4 This specification is applicable to orders in eitherinch-pound units or SI units. Values in inch-pound and SI unitsare not necessarily equivalent. Within the text, SI units areshown in brackets. Each s
6、ystem shall be used independently ofthe other.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regul
7、atory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2A902 Terminology Relating to Metallic Coated Steel Prod-uctsA917 Specification for Steel Sheet, Coated by the Electro-lytic Process forApplications Requiring Designation of theCoating Mass on Each Surface (General Requirements
8、)A924/A924M Specification for General Requirements forSteel Sheet, Metallic-Coated by the Hot-Dip Process3. Terminology3.1 DefinitionsSee Terminology A902 for definitions ofgeneral terminology relating to metallic-coated hot-dip prod-ucts.3.2 The definitions and procedures for measuring thicknesscha
9、racteristics of steel sheet products are provided so thatpurchasers and suppliers have common definitions and mea-suring procedures for thickness measurements. The intentionof these definitions and measuring methods is not to providedimensional specifications for thickness characteristics, butrather
10、 common procedures for quantifying thickness values.For determining compliance with thickness specifications,references are provided to appropriate ASTM standards.4. Apparatus4.1 Micrometers used for thickness measurement shall beconstructed with anvils and spindles having minimum diam-eters of 0.18
11、8 in. 4.80 mm. The tip of the anvil shall be flator rounded with a minimum radius of curvature of 0.10 in.2.55 mm and the tip of the spindle shall be flat. Micrometerswith conical tips, rounded anvil with rounded spindle, pointedtips or any surface that may penetrate the surface of the itembeing mea
12、sured shall not be used for thickness measurementsof sheet steels. Micrometers can be electronic digital, mechani-cal digital, or analog with vernier scale, as shown in Fig. 1(a),(b), and (c).4.2 Unlock the micrometer and if electronic digital, turn iton.4.3 Typical ways to hold/secure the micromete
13、r are:4.3.1 Grasp the micrometer as shown in Fig. 2, with thesmall finger placed in the frame of the micrometer for support.This allows the other hand to insert the sample for measuringafter cleaning (see 4.4).4.3.2 Support the micrometer with a micrometer mount.This allows the other hand to insert
14、the sample after cleaning(see 4.4). Inserting the sample with one hand while lightlyclamping with the other hand, as shown in Fig. 3.4.4 Clean the micrometer tips at regular intervals. Placecleaning material, such as clean dry paper, lint free cloth,cardboard or fabric (not abrasive such as sandpape
15、r) in1This practice is under the jurisdiction of ASTM Committee A05 on Metallic-Coated Iron and Steel Products and is the direct responsibility of SubcommitteeA05.07 on Methods of Testing.Current edition approved May 1, 2012. Published May 2012. DOI:10.1520/A1073_A1073M-12.2For referenced ASTM stand
16、ards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, P
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMA1073A1073M2012STANDARDPRACTICEFORUSINGHANDMICROMETERSTOMEASURETHETHICKNESSOFNONMETALLICANDMETALLICCOATEDSTEELSHEET

链接地址:http://www.mydoc123.com/p-457452.html