ASTM A1045-2010(2014) Standard Specification for Flexible Poly &40 Vinyl Chloride&41 &40 PVC&41 Gaskets used in Connection of Vitreous China Plumbing Fixtures to Sanitary Drainage .pdf
《ASTM A1045-2010(2014) Standard Specification for Flexible Poly &40 Vinyl Chloride&41 &40 PVC&41 Gaskets used in Connection of Vitreous China Plumbing Fixtures to Sanitary Drainage .pdf》由会员分享,可在线阅读,更多相关《ASTM A1045-2010(2014) Standard Specification for Flexible Poly &40 Vinyl Chloride&41 &40 PVC&41 Gaskets used in Connection of Vitreous China Plumbing Fixtures to Sanitary Drainage .pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: A1045 10 (Reapproved 2014)Standard Specification forFlexible Poly (Vinyl Chloride) (PVC) Gaskets used inConnection of Vitreous China Plumbing Fixtures to SanitaryDrainage Systems1This standard is issued under the fixed designation A1045; the number immediately following the designation
2、indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers material and
3、 performancerequirements for plasticized PVC compression gaskets used inthe connection of residential and commercial vitreous chinaplumbing fixtures to 2, 3 and 4-in. sanitary drain lines. Thesetype gaskets are inserted into and compress against the insidediameter of the sewer pipe, closet or urinal
4、 flange whileattaching to the vitreous china plumbing fixture with a flexibleadhesive. The result is a gas- and water-tight seal.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for info
5、rmation onlyand are not considered standard.1.3 This standard does not purport to address all of thesafety concerns, is any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and to determine theapplicability of regula
6、tory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2A644 Terminology Relating to Iron CastingsD5926 Specification for Poly (Vinyl Chloride) (PVC) Gas-kets for Drain, Waste, and Vent (DWV), Sewer, Sanitary,and Storm Plumbing Systems2.2 ASME Standards:3ASME A112.19.2M Vitreous Chi
7、na Plumbing Fixtures3. Terminology3.1 DefinitionsFor definitions of terms in this specifica-tion refer to Terminology A644.3.2 Definitions of Terms Specific to This Standard:3.2.1 closet flange, na pipe fitting that secures the watercloset to the floor and the sanitary drain line.3.2.2 urinal, na pl
8、umbing fixture that receives only liquidbody waste and, on demand, conveys the waste through a trapseal into a gravity drainage system.3.2.3 urinal flange, na pipe fitting that secures a rearoutlet wall mounted urinal to the sanitary drain line.3.2.4 vitreous china plumbing fixture, nurinal and or w
9、atercloset.3.2.5 water closet, na plumbing fixture having a watercontaining receptor which receives liquid and solid body wasteand upon actuation conveys the waste through an exposedintegral trap seal into a gravity drainage system.4. Materials and Manufacture4.1 These type gaskets are manufactured
10、principally fromvirgin injection grade plasticized PVC compounds. Recycledmaterials may be used in this product in accordance withSection 5.4.2 Adhesives used in the attachment of vitreous chinaplumbing fixture gaskets shall be compatible with the compo-nent gasket material and the sanitary drain sy
11、stem. Butylrubber-based adhesives are known to have such characteristics.5. Gasket Requirements5.1 Physical and mechanical properties of plasticized PVCgaskets for the connection of vitreous china plumbing fixturesto the sanitary drainage system shall comply with SpecificationD5926.5.2 Gaskets shall
12、 be tested in accordance with Section 9 onpipe samples complying with applicable industry standards ofmaximum and minimum dimensions. It shall be permissible tomachine pipe samples to attain maximum or minimumdimensions, or both.1This specification is under the jurisdiction of ASTM Committee A04 on
13、IronCastings and is the direct responsibility of Subcommittee A04.75 on Gaskets andCoupling for Plumbing and Sewer Piping.Current edition approved Oct. 1, 2014. Published October 2014. Originallyapproved in 2005. Last previous edition approved in 2010 as A1045 10. DOI:10.1520/A1045-10R14.2For refere
14、nced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American Society of Mechanical Engineers (ASME), ASMEInt
15、ernational Headquarters, Two Park Ave., New York, NY 10016-5990, http:/www.asme.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.3 The gasket assembly when tested in accordance withSection 9 shall not leak.5.4 The gasket shall ac
16、commodate vitreous china plumbingfixtures and flanges conforming to applicable industry stan-dards.6. Dimensions, Mass, and Permissible Variations6.1 Gaskets shall conform to the dimensions and dimen-sional tolerances as agreed upon between the supplier andpurchaser. All dimensions shall be compatib
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMA104520102014STANDARDSPECIFICATIONFORFLEXIBLEPOLY40VINYLCHLORIDE4140PVC41GASKETSUSEDINCONNECTIONOFVITREOUSCHINAPLUMBINGFIXTURESTOSANITARYDRAINAGEPDF

链接地址:http://www.mydoc123.com/p-457339.html