《ASTM A1038-2005 Standard Practice for Portable Hardness Testing by the Ultrasonic Contact Impedance Method《使用超声接触阻抗法的便携式硬度试验的标准规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM A1038-2005 Standard Practice for Portable Hardness Testing by the Ultrasonic Contact Impedance Method《使用超声接触阻抗法的便携式硬度试验的标准规程》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: A 1038 05Standard Practice forPortable Hardness Testing by the Ultrasonic ContactImpedance Method1This standard is issued under the fixed designation A 1038; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of
2、last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the determination of comparativehardness values by applying the Ultrasonic Contact ImpedanceMeth
3、od (UCI Method).1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use
4、.2. Referenced Documents2.1 ASTM Standards:2A 370 Test Methods and Definitions for Mechanical Testingof Steel ProductsE10 Test Method for Brinell Hardness of Metallic Materi-alsE18 Test Methods for Rockwell Hardness and RockwellSuperficial Hardness of Metallic MaterialsE92 Test Method for Vickers Ha
5、rdness of Metallic Mate-rialsE 140 Test Method for Hardness Conversion Tables forMetalsE 384 Test Method for Microindentation Hardness of Ma-terials3. Terminology3.1 Definitions:3.1.1 UCI methodUltrasonic Contact Impedance, a hard-ness testing method developed by Dr. Claus Kleesattel in 1961based on
6、 the measurement of the frequency shift of a resonat-ing rod caused by the essentially elastic nature of the finite areaof contact between the indenter and the test piece during thepenetration.3.1.2 UCI hardness testa hardness testing practice using acalibrated instrument by pressing a resonating ro
7、d with adefined indenter, for example, a Vickers diamond, with a fixedforce against the surface of the part to be tested.3.1.3 calibrationdetermination of the specific values ofthe significant operating parameters of the UCI instrument bycomparison with values indicated by a standardized workbenchha
8、rdness tester or by a set of certified reference test pieces.3.1.4 verificationchecking or testing the UCI instrumentto ensure conformance with this practice.3.1.5 surface finishall references to surface finish in thispractice are defined as surface roughness (that is, Ra = averageroughness value).4
9、. Significance and Use4.1 The hardness of a material is a defined quantity havingmany scales and being dependent on the way the test isperformed. In order to avoid the creation of a new practiceinvolving a new hardness scale, the UCI method converts intocommon hardness values, for example, HV, HRC,
10、etc.4.2 The UCI hardness test is a superficial determination,only measuring the hardness condition of the surface con-tacted. The results generated at a specific location do notrepresent the part at any other surface location and yield noinformation about the material at subsurface locations.4.3 The
11、 UCI hardness test may be used on large or smallcomponents at various locations. It can be used to makehardness measurements on positions difficult to access, such astooth flanks or roots of gears.A. GENERAL DESCRIPTION OF INSTRUMENTSAND TEST PROCEDURE FOR UCI HARDNESSTESTING5. Apparatus5.1 Instrume
12、nts used for UCI hardness testing generallyconsist of (1) a probe containing a rod with a defined indenter,for example, a Vickers diamond, attached to the contacting endper Test Method E92and Test Method E 384, (2) vibrationgenerating means, (3) vibration detecting means, (4) electronicmeans for the
13、 numerical evaluation, and (5) a digital display,indicating the measured hardness number.5.2 UCI ProbesThere are different probes available forUCI hardness testing. They typically cover static loads rangingfrom 1 N to 98 N. See also Appendix X1. They come also in1This practice is under the jurisdict
14、ion of ASTM Committee A01 on Steel,Stainless Steel and Related Alloys and is the direct responsibility of SubcommitteeA01.06 on Steel Forgings and Billets.Current edition approved Jan. 1, 2005. Published February 2005.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact AS
15、TM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.different sizes with longer
16、and shorter sensor rods for specialsapplications. And they are developed in two versions, that is,manually operated or equipped with a servo-motor for auto-matic testing.5.3 Summary of PracticeIn conventional workbenchhardness testing like Brinell or Vickers testing according toTest Methods E10, E92
17、 and E 384, the hardness value isdetermined optically by the size of the indentation in thematerial generated by a certain test load, after the indenter hasbeen removed. In the mobile hardness test under applied loadaccording to the UCI method, however, the size of theproduced indents are not determ
18、ined optically. Instead thecontact area is derived from the electronically measured shiftof an ultrasonic resonance frequency. To carry out the UCI test,a probe containing the rod with the indenter is excited into alongitudinal ultrasonic oscillation of about 70 kHz by piezo-electric ceramicsthe so-
19、called zero frequency, which occurswhen the indenter is vibrating in air.A spring inside the probe applies the specified test load, thevibrating tip penetrates into the material creating an elasticcontact, which results in a positive frequency shift of theresonating rod. This shift is related to the
20、 size of the indent area(contact area of the indenter with the material). The size, inturn, is a measure for the hardness of the test material at a givenmodulus of elasticity, for example, HV(UCI) according to Eq1.Therefore, the frequency shift is relatively small for hardmaterials, because the inde
21、nter penetrates not very deep intothe test material leaving only a small indent.The frequency shift becomes larger if the indenter penetratesdeeper into the material, indicating medium hardness, inaccordance with the larger test indentations. Analogously, thefrequency shift becomes largest when soft
22、 materials are tested(see Fig. 2).The instrument constantly monitors the resonance frequency,calculates the frequency shift when the specified test load hasbeen reached either after the internal switch has triggered thecorresponding measurement frequency in the case of handheldprobes or after a spec
23、ific dwell time has been elapsed in thecase of motor driven probes. The instrument carries out theevaluation and calculations, and displays instantaneously thehardness value, for example, HV(UCI).UCI Vickers (1)Df 5 fEeff A! and HV 5FA_The frequency shift is a function of the indentation size of ade
24、fined indenter, for example, a Vickers diamond, at a givenmodulus of elasticity of the measurement system.Eq 1 describes the basic relation in comparison to thedefinition of the Vickers hardness value: Df = Frequency shift,A = indentation area, Eeff= effective elastic modulus (containsthe elastic co
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMA10382005STANDARDPRACTICEFORPORTABLEHARDNESSTESTINGBYTHEULTRASONICCONTACTIMPEDANCEMETHOD 使用 超声 接触

链接地址:http://www.mydoc123.com/p-457307.html