ASSE 1024-2004 Performance Requirements for Dual Check Backflow Preventers《双核对回路抑制器执行要求》.pdf
《ASSE 1024-2004 Performance Requirements for Dual Check Backflow Preventers《双核对回路抑制器执行要求》.pdf》由会员分享,可在线阅读,更多相关《ASSE 1024-2004 Performance Requirements for Dual Check Backflow Preventers《双核对回路抑制器执行要求》.pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、ASSE Standard #1024 - 2004ASSE Board Approved: February 2004Performance Requirements for Dual Check Backflow PreventersASSE InternationalDual Check Backflow Preventers iASSE #1024 - 2004General InformationNeither this standard, nor any portion thereof, may be reproduced without the written consent o
2、f ASSE International.No product may be said to be ASSE approved unless the manufacturer has applied to the ASSE has had his product tested according to the applicable ASSE Standards, and when the product has passed the test, displays the ASSE Seal on the product.Instructions for receiving the author
3、ization to display the Seal are available from ASSEs International Office. Organizations wishing to adopt or list any ASSE Standard should print the ASSE Standard number on the cover page first and in equal or larger type to that of the adopting or listing organization.ASSE InternationalMokena, Illi
4、noisCopyright 2004, 1994, 1988, 1979All rights reserved.ii Dual Check Backflow PreventersASSE #1024 - 2004Dual Check Backflow Preventers iiiASSE #1024 - 2004ForewordThis foreword shall not be considered a part of the standard, however, it is offered to provide background information.ASSE Internation
5、al is dedicated to the preservation of public health and safety through “Prevention Rather than Cure.”Prevention of contamination or pollution of potable water in plumbing systems is one of the major objectives of the Societys Standards Program, which is addressed to the development and promulgation
6、 of Standards embracing performance criteria for manufactured plumbing components designed to safeguard public health and safety.The recognition of probable sources or causes of contamination or pollution of a potable water system whereby it becomes unfit or undesirable for human consumption, is vit
7、al to the maintenance of its continued potability.There are two basic and practiced methods for the protection of potable water supplies:(a) Protection by containment is the isolation, by a suitable means, of the system within the premises supplied, which could be a source of contamination or pollut
8、ion, from the vendors or public water supply system.(b) Protection of each individual outlet within the premises which could be a source of contamination or pollution, by a suitable device or means.Protection by containment protects the vendors or public water supply only. It does not provide protec
9、tion within the premises supplied.In modern plumbing systems, there are many situations where backflow could occur due to back pressure conditions. In some cases the backflow of pollutants into the potable water system could cause serious health hazards, while in other cases the backflow of pollutan
10、ts into the potable water system would make it undesirable, yet not a health hazard, to the persons consuming it (low hazard).This standard focuses on those devices know as Dual Check Valves, which will fulfill “Low Hazard” protective needs.The devices described are suitable for either protection by
11、 containment at residential supply service lines, or protection of individual outlets where pollutants, which could be caused to enter the potable water, are of low hazard.iv Dual Check Backflow PreventersASSE #1024 - 2004These devices are generally suitable for cold water service under continuous o
12、r intermittent pressure conditions. Usage with hot water is limited to the temperature specified by the manufacturer, and when certified under this standard.This standard was first adopted in 1979, and was the latest addition to the ASSE Backflow Preventer Standards, each of which covers a different
13、 type of backflow protection device, each tailored to the protective requirements essential to the specific system conditions in which it is installed and the degree of hazard involved.Although many of the material specifications are detailed within Section 4.1 of this standard, it is the responsibi
14、lity of the manufacturer to comply with the requirements of the Safe Drinking Water Act, United States Public Law 93-523.This standard was promulgated in accordance with procedures developed by the American National Standards Institute (ANSI).Compliance with this standard does not imply acceptance b
15、y any code group unless the standard has been adopted by the code.Dual Check Backflow Preventers vASSE #1024 - 2004Richard J. ProspalProduct Standards Committee ChairmanProspal Consulting Services, Inc.Brunswick, OhioRand H. AckroydRand EngineeringNewburyport, MassachusettsMichael BeckwithState of W
16、isconsin Department of CommerceMadison, WisconsinGunnar O. CollinsCollins Backflow Specialists, Inc.Palatine, IllinoisJud CollinsOklahoma State Health DepartmentOklahoma City, OklahomaShannon M. Corcoran ASSE Standards CoordinatorWestlake, OhioA. Richard EmmersonGeneral InterestBuffalo Grove, Illino
17、isSteven HazzardASSE Staff EngineerWestlake, OhioDale HollowaySGS United States Testing CompanyTulsa, Oklahoma2003-04 Product Standards CommitteeMichael KobelInternational Association of Plumbing and Mechanical OfficialsWalnut, CaliforniaValentine Lehr, P.E.Lehr AssociatesNew York, New YorkPeter Mar
18、zecUnited Association of Plumbers and PipefittersWashington, D.C.Perry W. Meikle, Jr.Perry W. Meikle Consulting EngineerAntioch, CaliforniaShabbir RawalpindiwalaKohler CompanyKohler, WisconsinLynne Simnick International Code Council, Inc.Country Club Hills, IllinoisJack VilendrePrecision Plumbing Pr
19、oducts, Inc.Portland, OregonDavid ViolaPlumbing Manufacturers InstituteSchaumberg, IllinoisJoseph C. Zaffuto, P.E.ASSE Staff EngineerWestlake, Ohiovi Dual Check Backflow PreventersASSE #1024 - 2004Rand H. AckroydRand EngineeringNewburyport, MassachusettsRobert Castle, PEHoneywell Water ControlsWarwi
20、ck, Rhode IslandBill DunmireFEBCO, Division of SPX Valves and ControlsSt. Pauls, North CarolinaScott FarnhamFord Meter Box Co.Wabash, IndianaSteven HazzardASSE Staff EngineerWestlake, OhioJohn HigdonConbraco Industries, Inc.Matthews, North Carolina1024 Working GroupBob Martin, Jr.Wolverine Brass Wor
21、ksConway, South CarolinaTeresa MedranoWilkins, Division of ZurnPaso Robles, CaliforniaBrad NollWilkins, Division of Zurn IndustriesPaso Robles, CaliforniaGeorge SwensonFlomatic Valves - Flomatic Corp.Glens Falls, New YorkJoseph C. Zaffuto, P.E.ASSE Staff EngineerWestlake, OhioDual Check Backflow Pre
22、venters viiASSE #1024 - 2004Table of ContentsSection I . 11.0 General . 11.1 Application 11.2 Scope . 11.3 Reference Standards . 1Section II 22.0 Test Specimens 22.1 Samples Submitted for Test . 22.2 Drawings 22.3 Rejection 2Section III . 33.0 Performance Requirements and Compliance Testing 33.1 Con
23、nection Torque . 3Table 1 33.2 Hydrostatic Test of Complete Device . 3Figure 1 43.3 Hydrostatic Leakage Tests of Check Valves 4Figure 2 53.4 Flow and Pressure Loss . 5Table 2 63.5 Drip Tightness of Check Valves 63.6 Deterioration at Maximum Rated Temperature and Pressure 7Figure 3 8Table 3 83.7 Chec
24、k Valve Operation . 93.8 Dual Check Valve Integrity at Maximum Intermittent Rated . 9Table 4 9Section IV 104.0 Detailed Requirements . 104.1 Materials . 104.2 Repairability . 114.3 Instructions for Marking and Installation 11Section V . 125.0 Definitions . 12viii Dual Check Backflow PreventersASSE #
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASSE10242004PERFORMANCEREQUIREMENTSFORDUALCHECKBACKFLOWPREVENTERS 核对 回路 抑制器 执行 要求 PDF

链接地址:http://www.mydoc123.com/p-457120.html