ASSE 1014-2005 Performance Requirements for Backflow Prevention Devices for Hand-Held Showers《手动淋浴逆流防止执行要求》.pdf
《ASSE 1014-2005 Performance Requirements for Backflow Prevention Devices for Hand-Held Showers《手动淋浴逆流防止执行要求》.pdf》由会员分享,可在线阅读,更多相关《ASSE 1014-2005 Performance Requirements for Backflow Prevention Devices for Hand-Held Showers《手动淋浴逆流防止执行要求》.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、ASSE Standard #1014-2005ASSE Board Approved: January 2005Performance Requirements for Backflow Prevention Devices for Hand-Held ShowersASSE InternationalBackflow Prevention Devices for Hand-Held Showers iASSE Standard #1014-2005General InformationNeither this standard, nor any portion thereof, may b
2、e reproduced without the written consent of ASSE International.No product may be said to be ASSE approved unless the manufacturer has applied to ASSE, has had his product tested according to the applicable ASSE Standards, and when the product has passed the test, displays the ASSE Seal on the produc
3、t.Instructions for receiving the authorization to display the Seal are available from ASSEs International Office. Organizations wishing to adopt or list any ASSE Standard should print the ASSE Standard number on the cover page first and in equal or larger type to that of the adopting or listing orga
4、nization.ASSE InternationalMokena, IllinoisCopyright 2011, 2009, 2005, 1999, 1993, 1990All rights reserved.ii Backflow Prevention Devices for Hand-Held Showers ASSE Standard #1014-2005Backflow Prevention Devices for Hand-Held Showers iiiASSE Standard #1014-2005ForewordThis foreword shall not be cons
5、idered a part of the standard; however, it is offered to provide background information.ASSE standards are developed in the interest of consumer health and safety.Hand showers, sometimes identified as “telephone showers”, provide a desirable means for bathing as well as some therapeutic services. Th
6、e ASSE has recognized that these devices, due to their mobility in service, can create unsanitary conditions in the potable water lines unless preventative means are provided in the installation.Loss of water supply pressure can create a condition in which contaminated water can be caused to backflo
7、w into the potable water lines. This could occur when a hand-held shower is submersed in non-potable water; and therefore it is essential that adequate means to protect against backflow be provided.Loss of water pressure is not a frequent occurrence, but it is a possibility. Many plumbing codes mand
8、ate that all hand-held shower installations be provided with means of protecting against backsiphonage and backpressure conditions. This performance standard has been developed around well established and extensively field tested principles for backflow prevention devices of this class. The updates
9、included in the 2005 edition of ASSE 1014 are intended to refine the scope and application to backflow prevention devices that are separately attached or integral to hand-held showers, while relying on ASME A112.18.1 Plumbing Fixture Fittings for the remaining performance requirements. Other devices
10、 such as those complying with ASSE Standard #1001 and ASSE Standard #1011, when installed in a properly designed system, can provide equivalent protection from backsiphonage and/or backpressure.Recognition is made of the time volunteered by members of this working group and of the support of the man
11、ufacturers who also participated in the meetings for this standard.The standard does not imply ASSEs endorsement of a product which conforms with these requirements.Compliance with this standard does not imply acceptance by any code body.It is recommended that these devices be installed consistent w
12、ith local codes. This standard was promulgated in accordance with procedures developed by the American National Standards Institute (ANSI).iv Backflow Prevention Devices for Hand-Held Showers ASSE Standard #1014-2005Richard J. ProspalProduct Standards Committee ChairmanProspal Consulting Services, I
13、nc.Brunswick, OhioRand H. AckroydRand EngineeringNewburyport, MassachusettsMichael BeckwithState of Wisconsin Department of CommerceMadison, WisconsinGunnar O. CollinsCollins Backflow Specialists, Inc.Palatine, IllinoisJud CollinsOklahoma State Health DepartmentOklahoma City, OklahomaShannon M. Corc
14、oran ASSE Standards CoordinatorWestlake, OhioA. Richard EmmersonGeneral InterestBuffalo Grove, IllinoisCharles GrossInternational Association of Plumbingand Mechanical OfficialsWalnut, CaliforniaSteven HazzardASSE Staff EngineerWestlake, Ohio2003-04 Product Standards CommitteeDale HollowaySGS United
15、 States Testing CompanyTulsa, OklahomaValentine Lehr, P.E.Lehr AssociatesNew York, New YorkPeter MarzecUnited Association ofPlumbers and PipefittersWashington, D.C.Perry W. Meikle, Jr.Perry W. Meikle Consulting EngineerAntioch, CaliforniaShabbir RawalpindiwalaKohler CompanyKohler, WisconsinLynne Sim
16、nick International Code Council, Inc.Country Club Hills, IllinoisJack VilendrePrecision Plumbing Products, Inc.Portland, OregonDavid ViolaPlumbing Manufacturers InstituteSchaumberg, IllinoisJoseph C. Zaffuto, P.E.ASSE Staff EngineerBackflow Prevention Devices for Hand-Held Showers vASSE Standard #10
17、14-2005Gunnar O. CollinsCollins Backflow Specialists, Inc.Palatine, IllinoisNick CovinoAmerican Standard, Inc.Piscataway, New JerseyA. Richard EmmersonGeneral InterestBuffalo Grove, IllinoisJames GalvinSymmons Industries, Inc.Braintree, MassachusettsSteven HazzardASSE Staff EngineerWestlake, OhioNor
18、man KummerlenMoen, Inc.North Olmsted, OhioMichael MartinezPrice PfisterLake Forest, CaliforniaLee MercerMoen, Inc.North Olmsted, Ohio1014 Working GroupJohn PetrovicAlsons / MixetHillsdale, MichiganShabbir RawalpindiwalaKohler CompanyKohler, WisconsinSally RemediosDelta Faucet CompanyIndianapolis, In
19、dianaMichael SantoraSpeakman Corp.Wilmington, DelawareGary TurnerWaterpik Technologies, Inc.Fort Collins, ColoradoDavid ViolaPlumbing Manufacturers InstituteSchaumburg, IllinoisJoseph C. Zaffuto, P.E.ASSE Staff EngineerWestlake, Ohiovi Backflow Prevention Devices for Hand-Held Showers ASSE Standard
20、#1014-2005Table of ContentsSection I . 11.0 General . 11.1 Application 11.2 Scope . 11.3 Reference Standards . 1Section II 22.0 Test Specimens 22.1 Samples Submitted 22.2 Samples Tested 22.3 Drawings 22.4 Rejection 2Section III . 33.0 Performance Requirements and Compliance Testing 33.1 Deterioratio
21、n at Extremes of Temperature and Pressure Test . 33.2 Life Cycle Test 33.3 Backpressure Test 4Figure 1 43.4 Backsiphonage Test . 4Figure 2 5Figure 3 5Section IV 64.0 Detailed Requirements . 64.1 Materials . 64.2 Installation Instructions . 64.3 Markings . 6Section V . 65.0 Definitions . 6Backflow Pr
22、evention Devices for Hand-Held Showers 1ASSE Standard #1014-2005Backflow Prevention Devices for Hand-Held ShowersSection I1.0 General1.1 ApplicationThis standard provides performance requirements for backflow prevention device(s) for hand-held showers (herein referred to as the “device”) in the inte
23、rest of health and safety.1.2 Scope1.2.1 DescriptionThese devices provide backflow protection against backsiphonage and backpressure in hand-held showers. These are separate devices or are integral with wall-mounted or deck-mounted tub fillers, flexible hoses, or components that are attached to show
24、er arms.1.2.2 General RequirementsThe device(s) and associated components shall comply with the requirements of this standard and the applicable requirements of ASME A112.18.1 unless stated otherwise herein.1.2.3 Minimum Working PressureThe device shall be designed to withstand an inlet working pres
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASSE10142005PERFORMANCEREQUIREMENTSFORBACKFLOWPREVENTIONDEVICESFORHANDHELDSHOWERS 手动 淋浴 逆流 防止 执行 要求 PDF

链接地址:http://www.mydoc123.com/p-457116.html