ARMY UFGS-12 21 00-2010 WINDOW BLINDS.pdf
《ARMY UFGS-12 21 00-2010 WINDOW BLINDS.pdf》由会员分享,可在线阅读,更多相关《ARMY UFGS-12 21 00-2010 WINDOW BLINDS.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-12 21 00 (August 2010)-Preparing Activity: USACE SupersedingUFGS-12 21 00 (February 2009)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2010*SECTION TABLE OF CONTENTSDIVISION 12 - FURNISHINGSSECTION 12 21 00WINDOW BLINDS08
2、/10PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 SYSTEM DESCRIPTION1.4 SUSTAINABLE DESIGN CERTIFICATION1.5 DELIVERY, STORAGE, AND HANDLING1.6 WARRANTYPART 2 PRODUCTS2.1 WINDOW BLINDS2.1.1 Horizontal Blinds2.1.1.1 Head Channel and Slats2.1.1.2 Controls2.1.1.3 Intermediate Brackets2.1.1.4 Bottom Rail2
3、.1.1.5 Braided Ladders2.1.1.6 Hold-Down Brackets2.1.1.7 Audio Visual Blinds2.1.2 Vertical Blinds2.1.2.1 Louvers2.1.2.2 Carriers2.1.2.3 Headrail System2.1.2.4 Valance2.1.2.5 Controls2.1.2.6 Connectors and Spacers2.1.2.7 Intermediate Brackets2.2 COLORPART 3 EXECUTION3.1 EXAMINATION3.2 WINDOW TREATMENT
4、 PLACEMENT SCHEDULE3.3 INSTALLATION3.3.1 Horizontal and Audio Visual BlindsSECTION 12 21 00 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.3.2 Vertical Blinds and Valance3.4 CLEAN-UP- End of Section Table of Contents -SECTION 12 21 00 Page 2
5、Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-12 21 00 (August 2010)-Preparing Activity: USACE SupersedingUFGS-12 21 00 (February 2009)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL
6、 dated July 2010*SECTION 12 21 00WINDOW BLINDS08/10*NOTE: This guide specification covers the requirements for window blinds and hardware.Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert a
7、ppropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments and suggestions on this guide specification are welcome and should be directed to the technical proponent of the specification. A listing of technical proponent
8、s, including their organization designation and telephone number, is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Request (CCR).PART 1 GENERAL*NOTE: Use Section 12 22 00 for CURTAINS AND DRAPES. Use Section 12 24 13 for ROLLER WINDOW SHADES*1.1 REFERENCES*NO
9、TE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature SECTIO
10、N 12 21 00 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to upd
11、ate the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publica
12、tions are referred to in the text by basic designation only.GREENGUARD ENVIRONMENTAL INSTITUTE (GEI)GEI Greenguard Standards for Low Emitting ProductsNATIONAL FIRE PROTECTION ASSOCIATION (NFPA)NFPA 701 (2010) Standard Methods of Fire Tests for Flame Propagation of Textiles and FilmsSCIENTIFIC CERTIF
13、ICATION SYSTEMS (SCS)SCS Scientific Certification Systems (SCS)Indoor Advantage1.2 SUBMITTALS*NOTE: Review submittal description (SD) definitions in Section 01 33 00 SUBMITTAL PROCEDURES and edit the following list to reflect only the submittals required for the project. Submittals should be kept to
14、 the minimum required for adequate quality control.A “G” following a submittal item indicates that the submittal requires Government approval. Some submittals are already marked with a “G”. Only delete an existing “G” if the submittal item is not complex and can be reviewed through the Contractors Q
15、uality Control system. Only add a “G” if the submittal is sufficiently important or complex in context of the project.For submittals requiring Government approval on Army projects, a code of up to three characters within the submittal tags may be used following the “G“ designation to indicate the ap
16、proving authority. Codes for Army projects using the Resident Management System (RMS) are: “AE“ for Architect-Engineer; “DO“ for District Office (Engineering Division or other organization in the District Office); “AO“ for Area Office; “RO“ for Resident Office; and “PO“ for Project Office. Codes SEC
17、TION 12 21 00 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-following the “G“ typically are not used for Navy, Air Force, and NASA projects.Choose the first bracketed item for Navy, Air Force and NASA projects, or choose the second bracketed
18、item for Army projects.*Government approval is required for submittals with a “G“ designation; submittals not having a “G“ designation are for Contractor Quality Control approval.information only. When used, a designation following the “G“ designation identifies the office that will review the submi
19、ttal for the Government. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURESSD-02 Shop DrawingsInstallationDrawings showing fabrication and installation details. Show layout and locations of track, direction of draw, mounting heights, and details.SD-03 Product DataWindow Bl
20、inds; G; G, _InstallationCertificationSD-04 SamplesWindow Blinds; G; G, _Valance; G; G, _Samples of each type and color of window treatment. Provide aluminum horizontal louver blind slatsvertical louvers 150 mm6 inch in length for each color. Provide 150 mm6 inch sample of horizontal blind slatsvert
21、ical louvers in each color specified.SD-06 Test ReportsWindow BlindsFire resistance, Flame Spread, and smoke contribution data.SD-08 Manufacturers InstructionsWindow Blinds; G; G, _SD-10 Operation and Maintenance DataWindow Blinds; G; G, _1.3 SYSTEM DESCRIPTIONProvide window treatment, conforming to
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYUFGS1221002010WINDOWBLINDSPDF