ARMY MIL-I-70698-1988 IMPROVED LIFTING TARGET ELEVATING MECHANISM 9375512《9375512改良起重目标升降机》.pdf
《ARMY MIL-I-70698-1988 IMPROVED LIFTING TARGET ELEVATING MECHANISM 9375512《9375512改良起重目标升降机》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-I-70698-1988 IMPROVED LIFTING TARGET ELEVATING MECHANISM 9375512《9375512改良起重目标升降机》.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-1-70698 (AR) 30 December 1988 MILITARY SPECIFICATION IMPROVED LIFTING TARGET ELEVATING MECHANISM: 9375512 This specification is approved for use within the U.S. Army Armament, Munitions and Chemical Command, and is available for use by all Departments and Agencies of the Department of Defense. 1
2、. SCOPE l*l Scope. This specification covers the Improved Lifting Target Elevating Mechanism (ILTEM) , Part No. 9375512, used on the Armor Moving Target Carrier (AMTC), Part No. 9365562, in the Remote Target System (RETS). 2. APPLICABLE DOCUMENTS 2.1 Government documents. 2.1.1 Specifications, stand
3、ards and handbooks. The following. specifications, standards and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Department of Defense Index of Specifications and Standards (DODISS)
4、and supplement thereto, cited in the solication (See 6.2) SPEC 1 F IC AT I ONS MI LI TARY MIL-F-13926 - Fire Control Material, General Specification Governing the Manufacture and Inspection of MIL-P-14232 - Parts, Equipment and Tools for Army Material, Packaging of MIL-1-45607 - Inspection Equipment
5、, Acquisition, Maintenance and Disposition of MIL-3-70694 - Electronic Control Unit Benccia comments (recommcndations, additions, deletions) and any pertinent data which may bc of use io improving this document should be addresscd to: Commander, U.S. Army Armament, Munitions, and Chemical Command, A
6、ftn. MShfC-QA, Picatinny Arsenal, New Jemy 07806-5000 by using the self-addressed Standardization Document Improvement Pro Em-Zkd. FSC 6920 -=- A Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL- 1-7 O 6 9 8 (AR) STANDARDS MIL I TARY MIL-STD-105 -
7、 Sampling Procedures and Tables for Inspection by Attributes MIL-STD-109 - Quality Assurance Terins and Definitions MIL- STD- 45 4 - Standard General Requirements for Electronics Equipment MIL-STD-8 10 - Environmental Test Methods (Unless otherwise indicated, copies of federal and military specifica
8、tions, standards, and handbooks are available from the Navel Publications and Forms Center, (ATTN: NPODS), 5801 Tabor Avenue, Philadelphia, PA 19120-5099.) 2.1.2 Other Government documents, drawings, and publications. The following other Government documents, drawings, and publica- tions form a part
9、 of this specification to the extent specified herein. Unless otherwise specified, the issues shall be those in effect on the date of the solicitation. DRAWINGS (See 6.4) U.S. ARMY ARMAMENT RESEARCH, DEVELOPMENT AND ENGINEERING CENTER (ARDEC) 9375512 - Improved Lifting Target Elevating 11784504 - El
10、ectronic Control Unit Mechanism 2.2 Order of precedence. In the event of conflict between the text of this specification and the references cited herein (except for associated detail specifications, specification sheets or MS standards), the text of this specification shall take precedence. Nothing
11、in this specification, however, shall supersede applicable laws and regulations unless a specific exemption has been obtained. 3 REQUIREMENTS 3.1 General description. ILTEM consists of an electrical and hydraulic unit operating a three (3) inch diameter cylinder which forces a rotating drive shaft t
12、hrough an angular distance of 90 degrees. A removable electronic control unit provides front panel controls for on/off mode operations and hit sensitivity selection. Electronic selection and use of the hit sensor provide the ability to implement control functions such as the visual hit indicator lam
13、p, target response to hits, the gunfire simulator and the visual hit smoke scorer. 2 c Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-1-70698 (AR) 3.2 Fabrication. The ILTEM shall be manufactured in accor- dance with drawing 9375512 and MIL-F-13
14、926. The electronic control unit shall meet MIL-E-70694. 3 . 3 Functions . 3.3.1 Commands. The ILTEM shall receive through its elec- tronic control unit cohnarids to raise target, to lower target, to activate visual hit indicator lamp and gunfire simulator. 3.3.2 Mechanism control. The mechanism is
15、remotely controlled and responds as follows: a. Upon receiving a remote raise or lower command signal the mechanism moves the target to the position commanded. The mechanism does not respond in any manner if commanded to a position that it is already in. b. The mode of operation is selectable direct
16、ly on the target device by a rotary switch. At position 0 al1 electrical power is removed from the electronic control unit. At position I, the target can be raised and lowered by remote command and hits on the target have no effect. At: position 2, the target can be raised and lowered by remote comm
17、and and a hit on the target when raised will lower and stay lowered until another raise remote signal is received. At position 3, the target can be raised and lowered by remote command and a hit on the target will lower, delay 11 seconds, and then automatically raise until another hit causes it to r
18、epeat the above operation. At positions 4, 5 and 6 the visual hit indicator lamp will illuminate when the target is hit. Modes 4, 5 and 6 are the same as modes 1, 2 and 3 except for visual hit indicator lamp operation. c. The smoke scorer when connected, will operate when the target is hit, on modes
19、 1 through 6. The target device has a manual momentary switch that permits testing the raise and lower cycle and visual hit indicator lamp illuminations. 3.3.3 Hostile fire simulator control. The target device will operate a hostile fire simulator when a remote command (fire) is sent. accessible fro
20、m the outside housing . The output circuit terminates in a single female -connector 3.4 Performance requirements. 3.4.1 Hydraulic oil tank. Capacity: 231 cubic inches. 3.4.2 Hydraulic electric motor. a. Voltage: 230 VAC, single phase. 3 Provided by IHSNot for ResaleNo reproduction or networking perm
21、itted without license from IHS-,-,- . -_- - MIL-I-70bSB b9 M 9799906 040Y722 3 a MIL- 1-7 O fi 9 8 (AR) b. Current: 10.2 amps. 3.4.3 Hydraulic pump. a. Max oil pressure: 2000 psi b. Relief valve: Adjustable c. Flow rate: 2 gal/min. 3.4.4 Hydraulic cylinder. a. Plunger diameter: 3.0 inches b. Pressur
22、e area: 7.068 square inches c. Inlet oil pressure max: 2000 psi d. Stroke length: 8.5 inches 3.4.5 Electronic control unit. a. Input voltage: 12 VDC b. Electronics regulated voltage: 8 VDC c. Relay operating voltage: 12 VDC 3.4.6 Output drive. a. Turning angle: 900, plus or minus So b. Maximuin torq
23、ue moment: 5600 foot-pounds C. Raise time with target: LO seconds d. Lower time with target: less than 8 seconds e. Maximum target board: 8.5 feet high x 20 feet wide x f. Maximum target weight: 350 pounds 0.5 inch thick 3.5 LI Environmental requirements. 3 . 5 . 1 3.5.1.1 Operating. The ILTEM shall
24、 meet the requirements of Temperature . 3.3 and 3.4 when thermally stabilized at -250 and at +1250, 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL- 1-70 69 8 (AR) 3.5.1.2 Non-operating (storage). The ILTEM shall not suffer permanent damage whe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILI706981988IMPROVEDLIFTINGTARGETELEVATINGMECHANISM93755129375512 改良 起重 目标 升降机 PDF

链接地址:http://www.mydoc123.com/p-445461.html