1、MIL-F-5L536 42 - 7777706 0235372 6 W E -I I- 2 June 1988 SUPERSEDING (See section 6) MITdITA12Y SPECIFICATION FILTER UNIT, GAS-PARTICULATE, 200 CFM, 208V, 400 HZ, M56 This specification is approved for use within the U.S. Army Chemical Research, Development and Engineering Center, Department of the
2、Army, and is available for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers one type of gas particulate filter unit capable of delivering filtered air at a rate of 200 cubic feet per minute (cfm) (see 6.1). 2. APPLICABLE DOCUMENTS 2.1 Go
3、vernment documents. 2.1.1 Specifications, standards, and handbooks. The following specifica- tions, standards, and handbooks form a part of this specification to the extent specified herein. Unless otherwise specified, the issues of these documents shall be those listed in the issue of the Departmen
4、t of Defense Index of Speci- fications an Standards (DODISS) and supplement thereto, cited in the solicita- tion. SPECIFICATIONS FEDERAL L-P-3 78 - Plastic Sheet and Strip, Thin Gauge, Polyolefin. FF-N-105 - Nails, Brads, Staples and Spikes: Wire, Cut and Wrought. PPP-B-587 - Boxes, Wood, Wirebound
5、Pallet Type. PPP-B-621 - Boxes, Wood, Nailed and Lock-Corner. PPP-B-636 - Boxes, Shipping, Fiberboard. PPP-C-843 - Cushioning Material, Cellulosic. : Beneficial comments (recommendations, additions, deletions) and any perti- : : nent data which may be of use in improving this document should be addr
6、essed: : to: Commander, U.S. Amy Chemical Research, Development and Engineering : : Center, ATTN: SMCCR-SPT-S, Aberdeen Proving Ground, MD 21010-5423 by using: : the self-addressed Standardization Document Improvement Proposal (DD Form : : 1426) appearing at the end of this document-or by letter. AM
7、SC N/A FSC 4240 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. L .,- THIS DOCUMENT CONTAINS I) PAGES. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-P-5L536 42 M 9499906 0235393 W PPP-C-1797 - Cushioning Materi
8、al, Resilient, Low Density, Unicellular, PPP-T-60 - Tape: Packaging, Waterproof. PPP-T-76 - Tape, Packaging, Paper (For Carton Sealing). PPP-T-97 - Tape, PackaginglIndustrial, Filament Reinforced. Polypropylene Foam. MILITARY MILIP-116 - Preservation, Methods of . MIL-B-117 - Bags, Sleeves and Tubin
9、g - Interior Packaging. MIL-F-51527 - Filter Set, Gas and Particulate. STANDARDS FEDERAL Fed. Std. No. 123 - Marking for Shipment (Civil Agencies). MILITARY MIL-STD-105 - Sampling Procedures and Tables for Inspection by MIL-STD-129 - Marking for Shipment and Storage. MIL-STD-781 - Reliability Testin
10、g for Engineering Development, Attributes. Qualification, and Production. HANDBOOKS MILITARY MIL-HDBK-781 - Reliability Test Methods, Plans, and Environments for Engineering Development, Qualification, and Produc- tion. 2.1.2 Drawings. The following drawings form a part of this specificaton to the e
11、xtent specified herein. those in effect on the date of the solicitation. Unless otherwise specified, the issues shail be DRAWINGS UmS. ARMY ARMAMENT, MUNITIONS AND CHEMICAL COMMAND CHEMICAL RESEARCH, DEVELOPMENT AND ENGINEERING CENTER 5-19-6402 - Filter Unit, Gas-Particulate, 200 CFM, 208V, 400 HZ,
12、5-19-6666 - Packing, Filter Unit, M56. 5-19-6417 - Container Marking, 1, 2 and 3 Filter Unit. M56 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-F-5153b L12 7777906 023537L1 T W (Copies of specifications, standards, handbooks, and drawings req
13、uired by con- tractors in connection with specific acquisition functions should be obtained from the contracting activity or as directed by the contracting activity.) 2.2 Order of precedence. In the event of a conflict between the text of this specification and the references cited herein (except fo
14、r associated detail specifications, specification sheets, or MS standards), the text of this specification shall take precedence. Nothing in this specification, however, shall supersede applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Materials and c
15、omponents. 3.1.1 Materials. All materials cited on Drawing 5-19-6402 and subsidiary drawings shall conform to the specifications listed thereon, and to the speci- fic characteristics set forth on the drawings. 3.1.2 Components. All components of the filter unit shall conform to the specifications an
16、d drawings listed on Drawing 5-19-6402 and subsidiary draw- ings. 3.2 Manufacture and assembly. The filter unit shall be manufactured and assembled in accordance with Drawing 5-19-6402. .3.3 Performance. 3.3.1 Cycling burn-in. The filter unit shall be cycled for a period of 3 hours during which time
17、 the airflow valve shall drive alternately to the fully open and then to the fully closed position (see 6.4) at a rate of 3 times per minute in response to an air pressure differential of 25 inches water gage (iwg) when tested in accordance with 4.4.4.2. 3.3.2 Operational characteristics. Prior to a
18、nd after completion of the cycling burn-in, the filter unit shall meet the following operational char- acteristics: 3.3.2.1 Airflow valve closing. The airflow valve shall start to drive closed between 1.2 and 1.7 iwg when tested in accordance with 4.4.4.3(b). 3.3.2.2 Airflow valve opening. The airfl
19、ow valve shall start to drive open between 1.2 and 1.7 iwg when tested in accordance with 4.4.4.3(c). 3.3.2.3 Warning horn and MASK indicator. The warning horn shall sound and the MASK indicator shall flash between 0.85 and 1.10 iwg when tested in accord- ance with 4.4.4.3(c) and 4.4.4.3(d). 3- - Pr
20、ovided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-F-51536 Li;! W 9979906 0235395 I m MIL-F-5 1536( EA) J1 3.3.2.4 Fan assembly rotational speed. The fan assembly impeller rotational speed shall be a minimum of 11,000 revolutions per minute when teste
21、d in accord- ance with 4.4.4.3(e). 3.4 Reliability. Prior to the start of regular production, a preproduction sample o 10 filter units shall be produced in accordance vith this specifica- tion for examination and test as follows: 3.4.1 Preproduction reliability qualification test. A sample of 4 filt
22、er units shall be randomly selected from the preproduction sample and tested in accordance with Task 302 of MIL-STD-781 and test plan IV-D of MIL-HDBK-781. The lower test mean-time-between-failure (01) shall be 467 hours and the upper test mean-time-between-failure (00) shall be 934 hours. units sha
23、ll be operated continuously in the configuration specified in 4.4.4.1 and 4.4.4.2 without temperature, vibration, or input voltage cycling. An accountable failure shall be defined as any deviation from the requirements specified in 3.3.2. The sample filter 3.5 Workmanship. The filter units shall be
24、free from cracked, bent or dented metal sections, and foreign matter (dirt, oil, or viscous materials). 40 QUALITY ASSURANCE PROVISIONS 4.1 Responsibility for inspection. Unless otherwise specified in the con- tract or purchase order, the contractor is responsible for the performance of a21 inspecti
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILF515361988FILTERUNITGASPARTICULATE200CFM208V400HZM56 毒气 颗粒 过滤器 机组 200 CFM208V400HZM56PDF

链接地址:http://www.mydoc123.com/p-444773.html