1、Designation: F2021 11 An American National StandardStandard Guide forDesign and Installation of Plastic Siphonic Roof DrainageSystems1This standard is issued under the fixed designation F2021; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This guide covers design and installation considerationsfor plastic siphonic roof drain systems
3、 for industrial,commercial, public, and residential buildings. Requirementsfor materials, pipe, and fittings are included.1.2 The interchangeability of pipe and fittings made bydifferent manufacturers is not addressed in this guide. Transi-tion fittings for joining pipe and fittings of different man
4、ufac-turers is provided for in the referenced pipe and fittingspecification.1.3 In referee decisions, the SI units shall be used formetric-sized pipe and inch-pound units for pipe sized in the IPSsystem (ANSI B36.10). In all cases, the values given inparentheses are for information only.2. Reference
5、d Documents2.1 ASTM Standards:2D696 Test Method for Coefficient of Linear Thermal Expan-sion of Plastics Between 30C and 30C with a VitreousSilica DilatometerD1600 Terminology forAbbreviated Terms Relating to Plas-ticsD1785 Specification for Poly(Vinyl Chloride) (PVC) PlasticPipe, Schedules 40, 80,
6、and 120D2661 Specification for Acrylonitrile-Butadiene-Styrene(ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipeand FittingsD2665 Specification for Poly(Vinyl Chloride) (PVC) PlasticDrain, Waste, and Vent Pipe and FittingsD2751 Specification for Acrylonitrile-Butadiene-Styrene(ABS) Sewer Pipe and
7、 Fittings (Withdrawn 2014)3D2949 Specification for 3.25-in. Outside Diameter Poly(Vi-nyl Chloride) (PVC) Plastic Drain, Waste, and Vent Pipeand FittingsD3034 Specification for Type PSM Poly(Vinyl Chloride)(PVC) Sewer Pipe and FittingsD3350 Specification for Polyethylene Plastics Pipe and Fit-tings M
8、aterialsE84 Test Method for Surface Burning Characteristics ofBuilding MaterialsE814 Test Method for Fire Tests of Penetration FirestopSystemsE1966 Test Method for Fire-Resistive Joint SystemsE2393 Practice for On-Site Inspection of Installed FireResistive Joint Systems and Perimeter Fire BarriersF4
9、12 Terminology Relating to Plastic Piping SystemsF628 Specification for Acrylonitrile-Butadiene-Styrene(ABS) Schedule 40 Plastic Drain, Waste, and Vent PipeWith a Cellular CoreF714 Specification for Polyethylene (PE) Plastic Pipe (DR-PR) Based on Outside DiameterF891 Specification for Coextruded Pol
10、y(Vinyl Chloride)(PVC) Plastic Pipe With a Cellular CoreF1901 Specification for Polyethylene (PE) Pipe and Fittingsfor Roof Drain Systems2.2 ANSI/ASME Standards:A112.20.2 Qualification of Installers of Firestop Systemsand Devices for Piping Systems4A112.6.4 Roof, Deck and Balcony Drains4A112.6.9 Sip
11、honic Roof Drains4B36.10 Standard Dimensions of Steel Pipe (IPS)42.3 ANSI/UL Standard:UL-1479 (see Test Method E814)42.4 Other References:International Building Code (IBC)International Plumbing Code (IPC)Uniform Plumbing Code (UPC)NFPA 5000 Building Code1This guide is under the jurisdiction of ASTM
12、Committee F17 on Plastic PipingSystems and is the direct responsibility of Subcommittee F17.63 on DWV.Current edition approved Aug. 1, 2011. Published September 2011. Originallyapproved in 2000. Last previous edition approved in 2006 as F2021 06. DOI:10.1520/F2021-11.2For referenced ASTM standards,
13、visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.4Availabl
14、e from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.
15、Terminology3.1 DefinitionsTerms and abbreviations as described inTerminologies F412 and D1600, respectively, shall apply inthis guide. General terminology pertaining to roof drains asdescribed in ANSI/ASME A112.6.4 and ASME A112.6.9 shallalso apply in this guide.3.2 Definitions of Terms Specific to
16、This Standard:3.2.1 crown, nthe elevation of the top of a pipe inner wall.3.2.2 drain, nany pipe which carries rain water, wastewater or waterborne wastes in a building drainage system.3.2.3 drainage system, nincludes all the piping withinpublic or private premises, which conveys sewage, rain water,
17、or other liquid wastes to a legal point of disposal. It does notinclude the mains of public sewer treatment or disposal plants.3.2.4 siphonic roof drain, na roof drain with a fixeddevice allowing water to enter without the ingress of air thatsustains a negative differential fluid head within the pip
18、esystem thereby inducing flow without pipe gradient (pitch).4. Significance and Use4.1 The information provided in this standard guide isintended for use by designers and specifiers of siphonic roofdrainage systems and their related components. Specifically,this guide addresses the use and limitatio
19、ns of plastic pipe andfittings in siphonic roof drainage systems where internaloperating pressures are typically sub-atmospheric.5. Procedure5.1 GeneralRefer to the governing plumbing code (forexample, IPC, UPC) to determine if plastic pipe and fittings arepermitted for building roof drainage system
20、s in the projectjurisdiction. When permitted, select the appropriate material aslisted in the plumbing code that is approved for roof drainageapplications. Use of plastic pipe materials not approved by thegoverning code must be approved by the local authority havingjurisdiction. Regardless of materi
21、al approval, use plastic pipematerials only when not prohibited by fire resistance require-ments of the governing building code (that is, NFPA 5000,IBC, UPC). Pipe materials must also meet the fire resistiverequirements as specified in the building code and as deter-mined by Test Method E84.5.1.1 Sp
22、ecific types of PVC pipe appropriate for siphonicroof drainage systems include, but are not limited to: Specifi-cations D2665, D2949, and D3034. When pipe diameters of212-in. (64-mm) must be specified, Specification D1785 plainend pressure pipe may be used as it shares the same manufac-turing standa
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMF20212011STANDARDGUIDEFORDESIGNANDINSTALLATIONOFPLASTICSIPHONICROOFDRAINAGESYSTEMS 塑料 虹吸 屋面 排水系统

链接地址:http://www.mydoc123.com/p-432995.html