1、MIL-L-27160C(USAF)3 March 1972 SupersedingMIL-L-7160B(USAF)16 Jul 1963MILITARY SPECIFICATIONLIGHTING, INSTRUMENT, INTEGRAL, WHITEGENERAL SPECIFICATION FOR1. SCOPE1.1 This specification covers the general requirements for a 5.0V illuminating system forintegrally white-lighted aircraft instruments usi
2、ng incandescent lamps as the light source.2. APPLICABLE DOCUMENTS2.1 The following documents, of this issue in effect on date of invitation for bids orrequest for proposal, form a part of this specification to the extent specified herein:SPECIFICATIONSMilitaryMIL-C-675 Coating of Glass Optical Eleme
3、nts (Anti-reflection)MIL-C-14806 Coating, Reflection Reducing, for Instrument Cover Glassesand Lighting WedgesSTANDARDSFederalFED-STD-595 ColorsMilitaryMS21376 Lamp Sub Miniature Helium Retardant Flange Base, T-1 SizeMS24367 Lamp, Incandescent - Miniature Integral LightingMS24515 Lamp - Sub Miniatur
4、eMS25237 Lamp, Incandescent, T-1 3/4 Bulb, Midget Flange BaseMS27569 Lamp, Incandescent - Miniature Integral Lighting, T-1 3/4 SizeMS27570 Lamp, Incandescent - Miniature Integral Lighting, T-1 1/4 SizeMS27571 Lamp, Incandescent - Miniature Integral Lighting, T-1 SizeProvided by IHSNot for ResaleNo r
5、eproduction or networking permitted without license from IHS-,-,-MIL-L-27160 (USAF)2(Copies of documents required by suppliers in connection with specific procurementfunctions should be obtained from the procuring activity or as directed by the contractingofficer.)3. REQUIREMENTS3.1 Qualification or
6、 preproduction. Qualification or preproduction provisions shall be asspecified in the applicable instrument specification.3.2 Materials. The instrument lighting system shall be of materials that will enable it towithstand the service, functional, and environmental conditions specified by the applica
7、bleinstrument specification.3.3 Design and construction. The lighting system shall be contained within the instrumentcase. A minimum of two lamps shall be used for each instrument. The lighting systemshall not interfere with the visibility of any portion of the dial or scale. No one portion ofthe di
8、splay shall depend upon one lamp for its illumination. The lighting system shall in noway interfere with correct operation of the instrument.3.3.1 Coverglass. The instrument coverglass and any other transparent element betweenthe coverglass and dial shall be coated with a reflection reducing film in
9、 accordance withMIL-C-675 or MIL-C-14806 as specified in the applicable instrument specification.3.3.2 Lamps. When any portion of helium is used in the filling medium of the instrument,only MS21376, MS27569, MS27570-8515AS15, MS27570-1191AS15, MS27571-6809AS15, or MS27571-6808AS15 lamps may be used.
10、 If helium is not used or if a non-hermetically sealed case is used, the MS25237-328AS10, MS24367-715AS15, MS24367-713AS15, MS24515-718AS15 lamps may be used in addition to the above lamps. Anylamp selected shall be used throughout the system.3.3.2.1 Lamp location. Lamps may be accessible either fro
11、m the outside of theinstrument or contained within the instrument case. Where practicable, lamps shall beremovable without opening the case. In-flight replacement will not be required. Whereapplicable instrument specification required hermetic sealing, lamps need not be containedwithin the seal.3.3.
12、2.2 Lamp circuit. The lamp circuit shall be designed to operate from a 5.0V 400-Hzpower system. All lamps shall be connected in parallel. In all applications, the circuit shallterminate in two pins which shall be used solely for the lamp circuit. Resistors ortransformers shall not be used within the
13、 instrument to change to voltage applied to thelamp terminals. (Wiring between the two lighting terminals on the connector and the lampsocket or terminals shall be of sufficient size to prevent any appreciable voltage drop in thewiring.)Provided by IHSNot for ResaleNo reproduction or networking perm
14、itted without license from IHS-,-,-MIL-L-27160 (USAF)33.3.2.2.1 Dielectric. The lamp circuit shall withstand 500V plus twice the lamp circuitdesign voltage at 60 Hz for one minute under the conditions specified in 4.5.7.3.3.3 Life and reliability. The lighting system shall be designed for a life of
15、1,000 hours orfor the period required by the applicable instrument specification, whichever is greater.Reliability shall be in accordance with the applicable detail specification.3.3.4 Color. The color of the white portions of the indicator display with 4.50 0.050Vapplied to the lighting terminals s
16、hall be x = 0.440 0.020 and y = 0.405 0.020 whenmeasured as specified herein.3.3.5 Brightness. When 4.50 0.050V are applied to the lighting terminals, the lightintensity and distribution shall be as follows:a. White areas: 1.00 0.50 foot-lambert. The average of all readings taken in thewhite areas s
17、hall be 1.00 0.30 foot-lamberts.b. Gray area: 0.60 0.30 foot-lambert.c. Black areas: 0.05 0.03 foot-lambert when reflected light (wedge and ring lighting) is used and 0.04 0.02 foot-lambert for refracted light (back lighting).d. Pointers, lubber lines, command bars, miniature airplane symbols deviat
18、ion bars, andother similar reference marks:1.20 0.50 foot-lambert. The average brightness of all of the (pointer) readings shall be 0.10 to 0.50 foot-lamberts higher than the average brightness of the (dial) white areas.e. Red areas: 1.00 0.50 foot-lambert.The brightness of other colors and the sele
19、ction of colors shall be governed by theirrelative brightness in daylight and shall be subject to the approval of the procuring activity.When no other guidance is available, the brightness of these other colored areas shall be1.0 0.50 foot-lambert.3.3.6 Stray light. The lighting system shall be so h
20、oused as to prevent the leakage ofstray light and to shield all lamp filaments from direct view.3.3.7 Light leakage. The lighting system shall in no way restrict the visibility of anygraduations, numerals, pointers, or other specific markings.Provided by IHSNot for ResaleNo reproduction or networkin
21、g permitted without license from IHS-,-,-MIL-L-27160 (USAF)43.3.8 Knobs and lettering. Unless otherwise specified in the applicable instrumentspecification, all indicia associated with instrument knob positions and all lettering on theinstrument face shall be illuminated. The brightness range shall
22、be as specified herein.3.4 Indicia. The presentation may be combination of white, black, and gray as specified inthe applicable instrument specification. Unless otherwise specified in the applicableinstrument specification, the colors shall conform to Table I.Table I. ColorsColor Color No. as listed
23、 inFED-STD-595White 37875Black 37038Gray 364403.5 Contrast. Contrast between the white and black portions of the indicator scale shallbe 12 or greater. Contrast between the gray and black portions of the indicator scale shallbe five or greater. Contrast, C, is defined as:C = B2- B1B1Where: B2is the
24、brightness of the gray or white, and B1is the brightness of the blackportions of the instrument scales.4. QUALITY ASSURANCE PROVISIONS4.1 Responsibility for inspection. Unless otherwise specified in the contract or purchaseorder, the supplier is responsible for the performance of all inspection requ
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEMILL27160C1972LIGHTINGINSTRUMENTINTEGRALWHITEGENERALSPECIFICATIONFOR 白色 整合 照明 装置 通用 规范 PDF

链接地址:http://www.mydoc123.com/p-428047.html