AIR FORCE A-A-59661 A-2009 MEASUREMENT SET TRANSMISSION IMPAIRMENT《输送损耗测量装置》.pdf
《AIR FORCE A-A-59661 A-2009 MEASUREMENT SET TRANSMISSION IMPAIRMENT《输送损耗测量装置》.pdf》由会员分享,可在线阅读,更多相关《AIR FORCE A-A-59661 A-2009 MEASUREMENT SET TRANSMISSION IMPAIRMENT《输送损耗测量装置》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、FSC 6625 A-A-59661A 20 November 2009 Superseding A-A-59661 October 19, 2004 COMMERCIAL ITEM DESCRIPTION MEASUREMENT SET, TRANSMISSION IMPAIRMENT The General Services Administration has authorized the use of this Commercial Item Description (CID) for all federal agencies. 1. SCOPE. This Commercial It
2、em Description (CID) describes a hand-held Transmission Impairment Measurement Set (TIMS). This CID is meant as a minimum requirement for the TIMS in which only those manufacturers that meet or surpass the following requirements are to supply the TIMS per this CID. The TIMS makes level, frequency, n
3、oise, P/AR (Peak-to-Average-Ratio), and signal-to-noise ratio measurements on 2-wire and 4-wire telephone circuits as well as testing for phase jitter, amplitude jitter, gain hits, phase hits, and dropouts. 2. SALIENT CHARACTERISTICS. The equipment shall be capable of operation within the accuracies
4、, limits, and specifications herein. 2.1 Classification. Equipment covered by this CID shall be commercially available equipment and may be modified to the extent necessary to meet this description. The equipment shall be Class 3 in accordance with MIL-PRF-28800, except as specified herein. 2.2 Safe
5、ty and Environmental. The TIMS shall meet all safety and environmental requirements as specified in MIL-PRF-28800 for the classification as stated herein except as specified herein. 2.2.1 Temperature Operating. The TIMS shall conform to its specified performance and accuracy while being operated in
6、a temperature range of 0C to +40C. 2.2.3 Temperature Non-operating. The TIMS shall conform to its specified performance and accuracy after being stored in the temperature range of -10C to +60C. INCH-POUNDBeneficial comments, recommendations, additions, deletions, clarifications, etc. and any other d
7、ata that may improve this document should be sent to WR-ALC/742 CBSG/GBEC, 460 Richard Ray Blvd, Robins AFB, GA 31098-1611. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at http:/assist.daps.dla.mil . Provided b
8、y IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59661A 2 2.3 Electrical Power Sources. The equipment shall operate from an internal, rechargeable battery pack for a minimum of three hours, and shall be equipped with an AC adapter to supply power to an inte
9、rnal recharging circuit. Battery recharge time shall be a maximum of four hours. The AC adapter shall operate from nominal line voltages of 110 volts AC (10%) and frequencies of 45 Hz to 60 Hz. Transient state conditions shall meet MIL-PRF-28800 requirements for the classification specified herein.
10、2.4 Reliability. The design of the equipment shall be such that under normal use and operation the equipment does not fail within 1500 hours of operation with a statistical certainty of 95%. 2.5 Calibration and Maintenance Adjustments. The design of the system shall provide for readily accessible ca
11、libration adjustments and maintenance adjustments. The calibration adjustments, wherever possible, shall be accessible without removal of the instrument case or modules. The calibration interval shall be a period of one year or greater based on an operating time of 2000 hours. No special tools shall
12、 be required for alignment or adjustment except those furnished with the equipment. 2.6 Performance Requirements. The TIMS shall meet all requirements specified herein, under all combinations of input power conditions, output signal conditions and operating service condition as specified in MIL-PRF-
13、28800. The TIMS shall meet or exceed the following measurement parameters in accordance with IEEE 743-1995, or the equivalent measurement parameters, except as specified herein. IEEE 743-1984 equivalent measurement parameters are acceptable. 2.6.1 Test Set Receiver Specifications. 2.6.1.1 Frequency.
14、 (a) Range 200 Hz to 19,999 Hz (b) Resolution 1 Hz (200 Hz to 9,999 Hz) 10 Hz (10 kHz to 19,999 Hz) (c) Accuracy 1 Hz (200 Hz to 9,999 Hz) 10 Hz (10 kHz to 19,999 Hz) 2.6.1.2 Level. (a) Range -49.9 dBm to +10 dBm (b) Resolution 0.1 dB (c) Accuracy 0.1 dB (-19 dBm to 0 dBm) at a fixed frequency betwe
15、en 1002 Hz to 1020 Hz 0.2 dB (-40 dBm to +10 dBm)(200 Hz - 14,999 Hz) 0.5 dB (-40 dBm to +10 dBm)(15 kHz - 19,999 Hz) 0.4 dB (-49.9 dBm to -40 dBm)(200 Hz - 14,999 Hz) 0.8 dB (-49.9 dBm to -40 dBm)(15 kHz - 19,999 Hz) (d) Detectors true rms or average 2.6.2 Test Set Transmitter Specifications. Provi
16、ded by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59661A 3 2.6.2.1 Tone generators, common requirements. 2.6.2.1.1 Level. (a) Range -40 dBm to +10 dBm (b) Resolution 0.1 dB (c) Accuracy 0.2 dB (200 Hz to 14,999 Hz) 0.5 dB (15 kHz to 19,999 Hz) 2.6.2.2 V
17、ariable frequency generator. 2.6.2.2.1 Frequency. (a) Range 200 Hz to 19,999 Hz (b) Resolution 1 Hz (200 Hz to 9,999 Hz) 10 Hz (10 kHz to 19,999 Hz) (c) Accuracy 1 Hz (200 Hz to 9,999 Hz) 10 Hz (10 kHz to 19,999 Hz) 2.6.2.2.2 Flatness. (a) 0.2 dB from 200 Hz to 15 kHz (b) 0.5 dB elsewhere 2.6.2.2.3
18、SF Skip. Skip Frequency of 2450 Hz to 2750 Hz. 2.6.2.3 Holding tone generator. 2.6.2.3.1 Frequency. (a) Range One or more fixed frequencies from 1002 Hz to 1022 Hz (b) Accuracy 0.005 Hz 2.6.2.3.2 Spurious Noise. Any generator used as a source of holding tone shall have: (a) 0.2 phase jitter or less
19、(b) 0.2% amplitude jitter or less (c) No impulse noise at a level 20 dB below the power of the tone (d) No phase hits greater than 3 (e) No gain hits greater than 0.5 dB (f) A signal-to-total-distortion ratio (S/TD) of at least 50 dB 2.6.3 Test Set Measurement Capabilities. Provided by IHSNot for Re
20、saleNo reproduction or networking permitted without license from IHS-,-,-A-A-59661A 4 2.6.3.1 Noise Measurements. Transmitter Mode: quiet termination. Receiver: (a) Level Range 10 dBrn to 90 dBrn (b) Resolution 1 dB (c) Accuracy 2 dBrn, 10 dBrn to 20 dBrn 1 dBrn, 20 dBrn to 90 dBrn Detector: True RM
21、S Filters: C-message, 3 kHz flat, 15 kHz flat 2.6.3.2 Noise With Tone Measurements. Transmitter Mode: holding tone. Receiver: (a) Level Range 10 dBrn to 90 dBrn (b) Resolution 0.1 dB (c) Resolution 1 dB (d) Accuracy 2 dBrn, 10 dBrn to 20 dBrn 1 dBrn, 20 dBrn to 90 dBrn Detector: True RMS Filters: C-
22、notched, 3 kHz Flat-notched 2.6.3.3 Signal-to-Total Distortion (S/TD) Ratio. Transmitter Mode: Holding tone Measurement: (a) Range 10 dB to 45 dB (b) Resolution 1 dB (c) Holding Tone Level -40 dBm to +10 dBm (d) Accuracy 1 dB (10 dB to 30 dB) 2 dB (31 dB to 45 dB) Detector: True RMS Filters: C-notch
23、ed 2.6.3.4 Transients. Transmitter Mode: holding tone Receiver: (a) Holding Tone Level -40 dBm to +10 dBm (b) Filter C-message, C-notched (c) Count Range 0 to 998 or greater for each level (d) Count rate 8 counts per second 10% (e) Timer Interval 0 to 60 minutes or more in less 1 min or less steps A
24、ccuracy 5% or better Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59661A 5 2.6.3.4.1 Three-level Impulse Noise. Threshold reference setting: (a) Range 30 dBrn to 104 dBrn in 1 dB steps (b) Accuracy 1 dB (c) Threshold Delta 3 levels min., at le
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEAA59661A2009MEASUREMENTSETTRANSMISSIONIMPAIRMENT 输送 损耗 测量 装置 PDF

链接地址:http://www.mydoc123.com/p-427134.html